Inability to assess breath sounds during air medical transport by helicopter.

R C Hunt1, D M Bryan, V S Brinkley, T W Whitley, N H Benson.   

Abstract

This study assessed the capabilities of a traditional and an amplified stethoscope used by flight nurses to assess breath sound during air medical transport in an MBB BO-105 helicopter. We developed a normal breath sound model using a prerecorded tape of breath sounds interspersed with segments without breath sounds; the recorder had been placed in the chest wall of a resuscitation training manikin. Flight nurses completed control listening sessions in a quiet environment and experimental sessions during flight using a traditional stethoscope for half of the sessions and an amplified stethoscope for the remaining half. In the quiet environment, flight nurses accurately reported the presence or absence of breath sounds in 110 (92%) of 120 trials. During helicopter flight, none of the flight nurses heard breath sounds during any of the recorded segments with either the traditional stethoscope or the amplified stethoscope. We conclude that flight nurses are unable to hear normal breath sounds using a traditional or amplified stethoscope during flight in a medically configured MBB BO-105 helicopter. Improved stethoscopes, innovative methods of listening, and reduction of aircraft noise are potential solutions to the problems of breath sound assessment during air medical transport.

Mesh:

Year:  1991        PMID: 2008028

Source DB:  PubMed          Journal:  JAMA        ISSN: 0098-7484            Impact factor:   56.272


  7 in total

1.  A randomized controlled trial of capnography in the correction of simulated endotracheal tube dislodgement.

Authors:  Melissa L Langhan; Kevin Ching; Veronika Northrup; Michelle Alletag; Payal Kadia; Karen Santucci; Lei Chen
Journal:  Acad Emerg Med       Date:  2011-06       Impact factor: 3.451

2.  The clinical evaluation of the Respi-check mask: a new oxygen mask incorporating a breathing indicator.

Authors:  A Breakell; C Townsend-Rose
Journal:  Emerg Med J       Date:  2001-09       Impact factor: 2.740

3.  Electrically amplified precordial stethoscope.

Authors:  P Biro
Journal:  J Clin Monit       Date:  1994-11

4.  Micropower impulse radar: a novel technology for rapid, real-time detection of pneumothorax.

Authors:  Phillip D Levy; Tracey Wielinski; Alan Greszler
Journal:  Emerg Med Int       Date:  2011-05-30       Impact factor: 1.112

5.  High fidelity medical simulation in the difficult environment of a helicopter: feasibility, self-efficacy and cost.

Authors:  Stewart W Wright; Christopher J Lindsell; William R Hinckley; Annette Williams; Carolyn Holland; Christopher H Lewis; Gail Heimburger
Journal:  BMC Med Educ       Date:  2006-10-05       Impact factor: 2.463

6.  Noninvasive Monitoring during Interhospital Transport of Newborn Infants.

Authors:  Georg M Schmölzer; Megan O'Reilly; Po-Yin Cheung
Journal:  Crit Care Res Pract       Date:  2013-02-24

Review 7.  ABCDE of prehospital ultrasonography: a narrative review.

Authors:  Rein Ketelaars; Gabby Reijnders; Geert-Jan van Geffen; Gert Jan Scheffer; Nico Hoogerwerf
Journal:  Crit Ultrasound J       Date:  2018-08-08
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.