Literature DB >> 20079750

Validation of near-infrared laser speckle imaging for assessing microvascular (re)perfusion.

Rick Bezemer1, Eva Klijn, Mostafa Khalilzada, Alexandre Lima, Michal Heger, Jasper van Bommel, Can Ince.   

Abstract

The present study was conducted to compare laser speckle imaging (LSI) with sidestream dark field (SDF) imaging (i.e., capillary microscopy) so as to validate the use of LSI for assessing microvascular (re)perfusion. For this purpose, LSI and SDF measurements were performed on the human nail fold during gradual occlusion of the upperarm circulation to modify nail fold perfusion under controlled circumstances. Additionally, a vascular occlusion test was performed to test the ability of LSI to detect rapid changes in tissue perfusion during reactive hyperemia and a hyperthermic challenge was performed to measure LSI perfusion at maximum functional capillary density. Normalized LSI measurements (i.e., normalized to baseline is 100%) were shown to correlate positively with normalized SDF measurements (Pearson's r=0.92). This was supported by linear regression analysis (slope of 1.01, R(2)=0.85, p<0.001). During the vascular occlusion test, LSI perfusion decreased from 307+/-90 AU (baseline) to 42+/-8 AU (ischemia). Peak perfusion during reperfusion was 651+/-93 AU (212% of baseline), which had returned to baseline after 2 min. Hyperthermia increased LSI perfusion from 332+/-90 AU to 1067+/-256 AU (321% of baseline). The main finding was that changes in perfusion as measured by LSI correlated well with changes in capillary red blood cell velocities as measured by SDF imaging during controlled reduction of the (micro)vascular perfusion. It was further shown that LSI is capable of measuring tissue perfusion at high temporal and spatial resolution. In conclusion, LSI can be employed to accurately quantitate microvascular reactivity following ischemic and hyperthermic challenges. Copyright 2009 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20079750     DOI: 10.1016/j.mvr.2010.01.004

Source DB:  PubMed          Journal:  Microvasc Res        ISSN: 0026-2862            Impact factor:   3.514


  8 in total

1.  Quantitative laser speckle flowmetry of the in vivo microcirculation using sidestream dark field microscopy.

Authors:  Annemarie Nadort; Rutger G Woolthuis; Ton G van Leeuwen; Dirk J Faber
Journal:  Biomed Opt Express       Date:  2013-10-07       Impact factor: 3.732

2.  The use of pulse pressure variation for predicting impairment of microcirculatory blood flow.

Authors:  Christoph R Behem; Michael F Graessler; Till Friedheim; Rahel Kluttig; Hans O Pinnschmidt; Anna Duprée; E Sebastian Debus; Daniel A Reuter; Sabine H Wipper; Constantin J C Trepte
Journal:  Sci Rep       Date:  2021-04-28       Impact factor: 4.379

3.  Rapid automatic assessment of microvascular density in sidestream dark field images.

Authors:  Rick Bezemer; Johannes G Dobbe; Sebastiaan A Bartels; E Christiaan Boerma; E Christiaan Boerma; Paul W G Elbers; Michal Heger; Can Ince
Journal:  Med Biol Eng Comput       Date:  2011-08-31       Impact factor: 2.602

4.  TEMPOL has limited protective effects on renal oxygenation and hemodynamics but reduces kidney damage and inflammation in a rat model of renal ischemia/reperfusion by aortic clamping.

Authors:  Bulent Ergin; Rick Bezemer; Asli Kandil; Cihan Demirci-Tansel; Can Ince
Journal:  J Clin Transl Res       Date:  2015-09-30

5.  Effects of different types of fluid resuscitation for hemorrhagic shock on splanchnic organ microcirculation and renal reactive oxygen species formation.

Authors:  Chun-Yu Wu; Kuang-Cheng Chan; Ya-Jung Cheng; Yu-Chang Yeh; Chiang-Ting Chien
Journal:  Crit Care       Date:  2015-12-11       Impact factor: 9.097

6.  Monitoring blood-flow in the mouse cochlea using an endoscopic laser speckle contrast imaging system.

Authors:  Tae Hoon Kong; Sunkon Yu; Byungjo Jung; Jin Sil Choi; Young Joon Seo
Journal:  PLoS One       Date:  2018-02-28       Impact factor: 3.240

7.  Skin microcirculatory reactivity assessed using a thermal challenge is decreased in patients with circulatory shock and associated with outcome.

Authors:  Diego Orbegozo; Wasineenart Mongkolpun; Gianni Stringari; Nikolaos Markou; Jacques Creteur; Jean-Louis Vincent; Daniel De Backer
Journal:  Ann Intensive Care       Date:  2018-05-03       Impact factor: 6.925

8.  Does the Application of Tecar Therapy Affect Temperature and Perfusion of Skin and Muscle Microcirculation? A Pilot Feasibility Study on Healthy Subjects.

Authors:  Ron Clijsen; Diego Leoni; Alessandro Schneebeli; Corrado Cescon; Emiliano Soldini; Lihui Li; Marco Barbero
Journal:  J Altern Complement Med       Date:  2019-10-03       Impact factor: 2.579

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.