Literature DB >> 20074240

Osseointegration of one-piece zirconia implants compared with a titanium implant of identical design: a histomorphometric study in the dog.

F P Koch1, D Weng, S Krämer, S Biesterfeld, A Jahn-Eimermacher, W Wagner.   

Abstract

OBJECTIVE: The aim of this study was to evaluate osseointegration of one-piece zirconia vs. titanium implants depending on their insertion depth by histomorphometry.
MATERIAL AND METHODS: Four one-piece implants of identical geometry were inserted on each side of six mongrel dogs: (1) an uncoated zirconia implant, (2) a zirconia implant coated with a calcium-liberating titanium oxide coating, (3) a titanium implant and (4) an experimental implant made of a synthetic material (polyetheretherketone). In a split-mouth manner they were inserted in submerged and non-submerged gingival healing modes. After 4 months, dissected blocks were stained with toluidine blue in order to histologically assess the bone-to-implant contact (BIC) rates and the bone levels (BL) of the implants.
RESULTS: All 48 implants were osseointegrated clinically and histologically. Histomorphometrically, BL in the crestal implant part did not differ significantly with regard to material type or healing modality. The submerged coated zirconia implants tended to offer the most stable crestal BL. The histometric results reflected the different healing modes by establishing different BL. The median BIC of the apical implant part of the zirconia and titanium group amounted to 59.2% for uncoated zirconia, 58.3% for coated zirconia, 26.8% for the synthetic material and 41.2% for titanium implants.
CONCLUSIONS: Within the limits of this animal study, it is concluded that zirconia implants are capable of establishing close BIC rates similar to what is known from the osseointegration behaviour of titanium implants with the same surface modification and roughness.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20074240     DOI: 10.1111/j.1600-0501.2009.01832.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  19 in total

1.  Bioactive and thermally compatible glass coating on zirconia dental implants.

Authors:  A Kirsten; A Hausmann; M Weber; J Fischer; H Fischer
Journal:  J Dent Res       Date:  2014-11-24       Impact factor: 6.116

Review 2.  Zirconia surface modifications for implant dentistry.

Authors:  Fernanda H Schünemann; María E Galárraga-Vinueza; Ricardo Magini; Márcio Fredel; Filipe Silva; Júlio C M Souza; Yu Zhang; Bruno Henriques
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2019-01-16       Impact factor: 7.328

Review 3.  Biomedical applications of nanotechnology.

Authors:  Ana P Ramos; Marcos A E Cruz; Camila B Tovani; Pietro Ciancaglini
Journal:  Biophys Rev       Date:  2017-01-13

4.  Bone tissue response to experimental zirconia implants.

Authors:  Ilja Mihatovic; Vladimir Golubovic; Jürgen Becker; Frank Schwarz
Journal:  Clin Oral Investig       Date:  2016-08-09       Impact factor: 3.573

5.  One-Piece Zirconia Ceramic versus Titanium Implants in the Jaw and Femur of a Sheep Model: A Pilot Study.

Authors:  A Siddiqi; W J Duncan; R K De Silva; S Zafar
Journal:  Biomed Res Int       Date:  2016-12-12       Impact factor: 3.411

6.  Biomechanical and histological evaluation of the osseointegration capacity of two types of zirconia implant.

Authors:  Jian-Min Han; Guang Hong; Hong Lin; Yoshinaka Shimizu; Yuhan Wu; Gang Zheng; Hongyu Zhang; Keiichi Sasaki
Journal:  Int J Nanomedicine       Date:  2016-12-07

7.  New Coating Technique of Ceramic Implants with Different Glass Solder Matrices for Improved Osseointegration-Mechanical Investigations.

Authors:  Enrico Mick; Jana Markhoff; Aurica Mitrovic; Anika Jonitz; Rainer Bader
Journal:  Materials (Basel)       Date:  2013-09-11       Impact factor: 3.623

Review 8.  Effect of Zirconia Dental Implant Surfaces on Bone Integration: A Systematic Review and Meta-Analysis.

Authors:  Ali Hafezeqoran; Roodabeh Koodaryan
Journal:  Biomed Res Int       Date:  2017-02-16       Impact factor: 3.411

9.  3D FEA Study On Implant Threading Role on Selection of Implant and Crown Materials.

Authors:  Ahmad Mohamad Wazeh; Mohamed I El-Anwar; Rami M Galal Atia; Rana Mohammed Mahjari; Sara Abdulelah Linga; Linah Mujeeb Alhaq Al-Pakistani; Salah Abdulazim Yousief
Journal:  Open Access Maced J Med Sci       Date:  2018-09-11

10.  A histomorphometric study on treated and untreated ceramic filled PEEK implants versus titanium implants: Preclinical in vivo study.

Authors:  Tarek A El Awadly; Gang Wu; Mohamed Ayad; Iman A W Radi; Daniel Wismeijer; Hamdy Abo El Fetouh; Reham B Osman
Journal:  Clin Oral Implants Res       Date:  2019-12-19       Impact factor: 5.977

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.