Literature DB >> 20071770

A basic dosimetric study of PRESAGE: the effect of different amounts of fabricating components on the sensitivity and stability of the dosimeter.

A Mostaar1, B Hashemi, M H Zahmatkesh, S M R Aghamiri, S R Mahdavi.   

Abstract

Over the past few years there has been much interest in the development of three-dimensional dosimeters to determine the complex absorbed dose distribution in modern radiotherapy techniques such as IMRT and IGRT. In routine methods used for three-dimensional dosimetry, polymer gels are commonly used. Recently, a novel transparent polymer dosimeter, known as PRESAGE, has been introduced in which a radiochromic color change is observed upon radiation. PRESAGE has some advantages over usual polymer gel dosimeters. It has been noted that the sensitivity of PRESAGE can be changed when different amounts of the components are used for its fabrication. This study has focused on the assessment of dosimetric characteristics of PRESAGE for various amounts of components in its formulation. To achieve this, PRESAGE dosimeters were fabricated using various amounts of their constituting components. Then the dosimeters were irradiated to (60)Co gamma photons for a range of radiation doses from 0 to 50 Gy. Consequently, the light absorption changes of the dosimeters were measured by a spectrophotometer at different post-irradiation time periods. It was generally observed that as the concentration of the radical initiator is increased, the PRESAGE dosimeter sensitivity is increased while its stability is decreased. Furthermore, it was noted that with the high concentration of the radical initiator and leuco dye, the sensitivity of PRESAGE is decreased.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20071770     DOI: 10.1088/0031-9155/55/3/023

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  An investigation of PRESAGE® 3D dosimetry for IMRT and VMAT radiation therapy treatment verification.

Authors:  Jake Jackson; Titania Juang; John Adamovics; Mark Oldham
Journal:  Phys Med Biol       Date:  2015-02-16       Impact factor: 3.609

Review 2.  Three-dimensional radiation dosimetry using polymer gel and solid radiochromic polymer: From basics to clinical applications.

Authors:  Yoichi Watanabe; Leighton Warmington; N Gopishankar
Journal:  World J Radiol       Date:  2017-03-28

Review 3.  A Review of PRESAGE Radiochromic Polymer and the Compositions for Application in Radiotherapy Dosimetry.

Authors:  Muhammad Zamir Mohyedin; Hafiz Mohd Zin; Mohd Zulfadli Adenan; Ahmad Taufek Abdul Rahman
Journal:  Polymers (Basel)       Date:  2022-07-16       Impact factor: 4.967

4.  Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques.

Authors:  Antony Palmer; David Bradley; Andrew Nisbet
Journal:  J Contemp Brachytherapy       Date:  2012-06-30

5.  Improvement in sensitivity of radiochromic 3D dosimeter based on rigid polyurethane resin by incorporating tartrazine.

Authors:  Jin Dong Cho; Jaeman Son; Chang Heon Choi; Jin Sung Kim; Hong-Gyun Wu; Jong Min Park; Jung-In Kim
Journal:  PLoS One       Date:  2020-03-16       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.