Literature DB >> 20071670

Use of EyeCam for imaging the anterior chamber angle.

Shamira A Perera1, Mani Baskaran, David S Friedman, Tin A Tun, Hla M Htoon, Rajesh S Kumar, Tin Aung.   

Abstract

PURPOSE: To compare EyeCam (Clarity Medical Systems, Pleasanton, CA) imaging with gonioscopy for detecting angle closure.
METHODS: In this prospective, hospital-based study, subjects underwent gonioscopy by a single observer and EyeCam imaging by a different operator. EyeCam images were graded by two masked observers. The anterior chamber angle in a quadrant was classified as closed if the trabecular meshwork could not be seen. The eye was classified as having angle closure if two or more quadrants were closed.
RESULTS: One hundred fifty-two subjects were studied. The mean age was 57.4 years (SD 12.9) and there were 82 (54%) men. Of the 152 eyes, 21 (13.8%) had angle closure. The EyeCam provided clear images of the angles in 98.8% of subjects. The agreement between the EyeCam and gonioscopy for detecting angle closure in the superior, inferior, nasal, and temporal quadrants based on agreement coefficient (AC1) statistics was 0.73, 0.75, 0.76, and 0.72, respectively. EyeCam detected more closed angles than did gonioscopy in all quadrants (P < 0.05). With gonioscopy, 21/152 (13.8%) eyes were diagnosed as angle closure compared to 41 (27.0%) of 152 with EyeCam (P < 0.001, McNemar Test), giving an overall sensitivity of 76.2% (95% confidence interval [CI], 54.9%-90.7%), specificity of 80.9% (95%CI, 73.5%-87.3%), and an area under the receiver operating characteristic curve (AUC) of 0.79.
CONCLUSIONS: The EyeCam showed good agreement with gonioscopy for detecting angle closure. However, it detected more closed angles than did gonioscopy in all quadrants.

Entities:  

Mesh:

Year:  2010        PMID: 20071670     DOI: 10.1167/iovs.09-4418

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  9 in total

1.  Preclinical imaging of iridocorneal angle and fundus using a modified integrated flexible handheld probe.

Authors:  Xun Jie Jeesmond Hong; Vengalathunadakal K Shinoj; Vadakke Matham Murukeshan; Mani Baskaran; Tin Aung
Journal:  J Med Imaging (Bellingham)       Date:  2017-04-10

2.  Glaucoma Expert-Level Detection of Angle Closure in Goniophotographs With Convolutional Neural Networks: The Chinese American Eye Study.

Authors:  Michael Chiang; Daniel Guth; Anmol A Pardeshi; Jasmeen Randhawa; Alice Shen; Meghan Shan; Justin Dredge; Annie Nguyen; Kimberly Gokoffski; Brandon J Wong; Brian Song; Shan Lin; Rohit Varma; Benjamin Y Xu
Journal:  Am J Ophthalmol       Date:  2021-02-09       Impact factor: 5.488

3.  Comparative evaluation of RetCam vs. gonioscopy images in congenital glaucoma.

Authors:  Raj V Azad; Parijat Chandra; Anuradha Chandra; Aparna Gupta; Viney Gupta; Ramanjit Sihota
Journal:  Indian J Ophthalmol       Date:  2014-02       Impact factor: 1.848

4.  High resolution iridocorneal angle imaging system by axicon lens assisted gonioscopy.

Authors:  Sandeep Menon Perinchery; Anant Shinde; Chan Yiu Fu; Xun Jie Jeesmond Hong; Mani Baskaran; Tin Aung; Vadakke Matham Murukeshan
Journal:  Sci Rep       Date:  2016-07-29       Impact factor: 4.379

Review 5.  Anterior Chamber Angle Assessment Techniques: A Review.

Authors:  Ivano Riva; Eleonora Micheletti; Francesco Oddone; Carlo Bruttini; Silvia Montescani; Giovanni De Angelis; Luigi Rovati; Robert N Weinreb; Luciano Quaranta
Journal:  J Clin Med       Date:  2020-11-25       Impact factor: 4.241

6.  Semantic segmentation of gonio-photographs via adaptive ROI localisation and uncertainty estimation.

Authors:  Andrea Peroni; Anna Paviotti; Mauro Campigotto; Luis Abegão Pinto; Carlo Alberto Cutolo; Jacintha Gong; Sirjhun Patel; Caroline Cobb; Stewart Gillan; Andrew Tatham; Emanuele Trucco
Journal:  BMJ Open Ophthalmol       Date:  2021-11-25

Review 7.  Recent advances in anterior chamber angle imaging.

Authors:  Natalia Porporato; Mani Baskaran; Rahat Husain; Tin Aung
Journal:  Eye (Lond)       Date:  2019-10-30       Impact factor: 3.775

8.  The role of anterior segment optical coherence tomography in glaucoma.

Authors:  Sarwat Salim
Journal:  J Ophthalmol       Date:  2012-08-01       Impact factor: 1.909

9.  A Population-Based Assessment of the Agreement Between Grading of Goniophotographic Images and Gonioscopy in the Chinese-American Eye Study (CHES).

Authors:  Yohko Murakami; Dandan Wang; Bruce Burkemper; Shan C Lin; Rohit Varma
Journal:  Invest Ophthalmol Vis Sci       Date:  2016-08-01       Impact factor: 4.799

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.