Literature DB >> 20071277

Multiple binary classifications via linear discriminant analysis for improved controllability of a powered prosthesis.

Levi J Hargrove1, Erik J Scheme, Kevin B Englehart, Bernard S Hudgins.   

Abstract

This paper describes a novel pattern recognition based myoelectric control system that uses parallel binary classification and class specific thresholds. The system was designed with an intuitive configuration interface, similar to existing conventional myoelectric control systems. The system was assessed quantitatively with a classification error metric and functionally with a clothespin test implemented in a virtual environment. For each case, the proposed system was compared to a state-of-the-art pattern recognition system based on linear discriminant analysis and a conventional myoelectric control scheme with mode switching. These assessments showed that the proposed control system had a higher classification error ( p < 0.001) but yielded a more controllable myoelectric control system ( p < 0.001) as measured through a clothespin usability test implemented in a virtual environment. Furthermore, the system was computationally simple and applicable for real-time embedded implementation. This work provides the basis for a clinically viable pattern recognition based myoelectric control system which is robust, easily configured, and highly usable.

Mesh:

Year:  2010        PMID: 20071277     DOI: 10.1109/TNSRE.2009.2039590

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  26 in total

1.  Improving myoelectric pattern recognition robustness to electrode shift by changing interelectrode distance and electrode configuration.

Authors:  Aaron J Young; Levi J Hargrove; Todd A Kuiken
Journal:  IEEE Trans Biomed Eng       Date:  2011-11-29       Impact factor: 4.538

2.  Determining delay created by multifunctional prosthesis controllers.

Authors:  Todd R Farrell
Journal:  J Rehabil Res Dev       Date:  2011

3.  The effects of electrode size and orientation on the sensitivity of myoelectric pattern recognition systems to electrode shift.

Authors:  Aaron J Young; Levi J Hargrove; Todd A Kuiken
Journal:  IEEE Trans Biomed Eng       Date:  2011-06-09       Impact factor: 4.538

4.  Design of a robust EMG sensing interface for pattern classification.

Authors:  He Huang; Fan Zhang; Yan L Sun; Haibo He
Journal:  J Neural Eng       Date:  2010-09-01       Impact factor: 5.379

5.  Evaluation of Computer-Based Target Achievement Tests for Myoelectric Control.

Authors:  Jacob Gusman; Enzo Mastinu; Max Ortiz-Catalan
Journal:  IEEE J Transl Eng Health Med       Date:  2017-11-29       Impact factor: 3.316

6.  Determining the optimal window length for pattern recognition-based myoelectric control: balancing the competing effects of classification error and controller delay.

Authors:  Lauren H Smith; Levi J Hargrove; Blair A Lock; Todd A Kuiken
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2010-12-30       Impact factor: 3.802

7.  A decision-based velocity ramp for minimizing the effect of misclassifications during real-time pattern recognition control.

Authors:  Ann M Simon; Levi J Hargrove; Blair A Lock; Todd A Kuiken
Journal:  IEEE Trans Biomed Eng       Date:  2011-05-16       Impact factor: 4.538

8.  A novel myoelectric pattern recognition strategy for hand function restoration after incomplete cervical spinal cord injury.

Authors:  Jie Liu; Ping Zhou
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2012-09-27       Impact factor: 3.802

9.  Classification of simultaneous movements using surface EMG pattern recognition.

Authors:  Aaron J Young; Lauren H Smith; Elliott J Rouse; Levi J Hargrove
Journal:  IEEE Trans Biomed Eng       Date:  2012-12-10       Impact factor: 4.538

Review 10.  On the viability of implantable electrodes for the natural control of artificial limbs: review and discussion.

Authors:  Max Ortiz-Catalan; Rickard Brånemark; Bo Håkansson; Jean Delbeke
Journal:  Biomed Eng Online       Date:  2012-06-20       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.