Vertebral column length and spread of hyperbaric subarachnoid bupivacaine in the term parturient.

B L Hartwell1, L S Aglio, M A Hauch, S Datta.   

Abstract

Patient height is considered an important determinant of the dose of spinal anesthesia. However, the relationship between body height and the level of sensory anesthesia with a fixed dose of spinal anesthetic has not been clearly documented. Recent evidence suggests no correlation between height or weight of parturients and spread of spinal anesthesia. Vertebral column length rather than body height may be more important in determining anesthetic spread. We studied the correlation between vertebral length measured from C7 to the level of the iliac crest (IC) and to the sacral hiatus (SH) and the sensory anesthetic level after the subarachnoid administration of 12 mg hyperbaric bupivacaine in term pregnant patients. There was no correlation between patient height, weight or body mass index and sensory anesthesia level. However, a significant correlation existed between vertebral length measured from C7 to IC (r = 0.32, p = 0.025) or to SH (r = 0.38, p = 0.006) and the level of anesthesia.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2007099

Source DB:  PubMed          Journal:  Reg Anesth        ISSN: 0146-521X


  12 in total

1.  The relationship between symphysis-fundal height and intravenous ephedrine dose in spinal anesthesia for elective cesarean section.

Authors:  Sung Hee Chung; Hyeon Jeong Yang; Jong-Yeon Lee; Kum-Hee Chung; Duk-Hee Chun; Byeong-Kuk Kim
Journal:  Korean J Anesthesiol       Date:  2010-09-20

2.  Relationship of abdominal circumference and trunk length with spinal anesthesia level in the term parturient.

Authors:  Yi-Hui Lee; Yi-Chia Wang; Man-Ling Wang; Pei-Lin Lin; Chi-Hsiang Huang; Hui-Hsun Huang
Journal:  J Anesth       Date:  2013-11-26       Impact factor: 2.078

3.  The impact of body mass index on the risk of high spinal block in parturients undergoing cesarean delivery: a retrospective cohort study.

Authors:  Agnes M Lamon; Lisa M Einhorn; Mary Cooter; Ashraf S Habib
Journal:  J Anesth       Date:  2017-04-18       Impact factor: 2.078

4.  The effect of body mass index on the spread of spinal block in patients with rheumatoid arthritis.

Authors:  Kari A Leino; Kristiina S Kuusniemi; Heikki K Pälve; Hannu T Tiusanen; Tapani T Tuppurainen
Journal:  J Anesth       Date:  2010-12-31       Impact factor: 2.078

Review 5.  Spinal anaesthesia in obstetrics.

Authors:  P Morgan
Journal:  Can J Anaesth       Date:  1995-12       Impact factor: 5.063

6.  The Levels and Duration of Sensory and Motor Blockades of Spinal Anesthesia in Obese Patients That Underwent Urological Operations in the Lithotomy Position.

Authors:  Taner Ciftci; Ali Bestemi Kepekci; Hatice Pınar Yavasca; Hayrettin Daskaya; Volkan İnal
Journal:  Biomed Res Int       Date:  2015-04-29       Impact factor: 3.411

7.  Obesity is independently associated with spinal anesthesia outcomes: a prospective observational study.

Authors:  Hyo-Jin Kim; Won Ho Kim; Hyung Woo Lim; Jie Ae Kim; Duk-Kyung Kim; Byung Seop Shin; Woo Seog Sim; Tae Soo Hahm; Chung Su Kim; Sangmin M Lee
Journal:  PLoS One       Date:  2015-04-21       Impact factor: 3.240

8.  Abdominal girth and vertebral column length aid in predicting intrathecal hyperbaric bupivacaine dose for elective cesarean section.

Authors:  Chang-Na Wei; Qing-He Zhou; Li-Zhong Wang
Journal:  Medicine (Baltimore)       Date:  2017-08       Impact factor: 1.889

9.  Height-based dosing algorithm of bupivacaine in spinal anaesthesia for decreasing maternal hypotension in caesarean section without prophylactic fluid preloading and vasopressors: study protocol for a randomised controlled non-inferiority trial.

Authors:  Bowan Huang; Qiang Huang; Chao Hai; Zihao Zheng; Yali Li; Zhongjun Zhang
Journal:  BMJ Open       Date:  2019-05-16       Impact factor: 2.692

Review 10.  Managing anesthesia for cesarean section in obese patients: current perspectives.

Authors:  Agnes M Lamon; Ashraf S Habib
Journal:  Local Reg Anesth       Date:  2016-08-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.