Literature DB >> 20070756

A randomized clinical 1-year trial comparing two types of non-submerged dental implants.

Jong-Chul Park1, Seung-Ryong Ha, Soung-Min Kim, Myung-Jin Kim, Jai-Bong Lee, Jong-Ho Lee.   

Abstract

OBJECTIVES: This study compared the implant stability and clinical outcomes obtained with two types of non-submerged dental implants that have different thread designs and surface treatments.
MATERIALS AND METHODS: A randomized clinical trial with 1 year of follow-up was performed on 56 participants with 75 implants (control group, 36 implants in 28 subjects; experimental group, 39 implants in 28 subjects). The experimental group received the Osstem SSII Implant system; the control group received the Standard Straumann Dental Implant System. The diameter and length of the fixture were uniform at 4.1 mm and 10 mm and all the implants restored the unilateral loss of one or two molars from the mandible. To compare implant stability, the peak insertion torque, implant stability quotient (ISQ), and periotest value (PTV) were evaluated during surgery, and at 4 and 10 weeks after surgery. To compare marginal bone loss, standard periapical radiographs were obtained during surgery, and at 10 weeks and 1 year after surgery.
RESULTS: This study showed statistically significant differences between the two groups in peak insertion torque (P=0.009) and ISQ (P=0.003) but not in PTV (P=0.097) at surgery. In contrast, there was no statistically significant difference in the pattern of change of ISQ during the 10 weeks after surgery (P=0.339). For marginal bone loss, no significant difference was observed between the control and the experimental groups before functional loading (P=0.624), but after 1 year of follow-up, a borderline difference was observed (P=0.048).
CONCLUSION: The success rate after 1 year of follow-up was 100% for both implant system despite the presence of a significant difference in implant stability during surgery. There was a borderline difference in marginal bone loss after 1 year of follow-up.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20070756     DOI: 10.1111/j.1600-0501.2009.01828.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  6 in total

Review 1.  WITHDRAWN: Interventions for replacing missing teeth: different types of dental implants.

Authors:  Marco Esposito; Yasmin Ardebili; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2019-10-10

2.  In vitro comparison of primary stability of two implant designs in D3 bone.

Authors:  J González-Serrano; R Ortega-Aranegui; J López-Quiles
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2017-07-01

Review 3.  Marginal bone loss 1 year after implantation: a systematic review for fixed and removable restorations.

Authors:  Jennifer Zimmermann; Melanie Sommer; Leticia Grize; Stefan Stubinger
Journal:  Clin Cosmet Investig Dent       Date:  2019-07-16

Review 4.  Sandblasted and Acid Etched Titanium Dental Implant Surfaces Systematic Review and Confocal Microscopy Evaluation.

Authors:  Gabriele Cervino; Luca Fiorillo; Gaetano Iannello; Dario Santonocito; Giacomo Risitano; Marco Cicciù
Journal:  Materials (Basel)       Date:  2019-05-30       Impact factor: 3.623

5.  Marginal Bone Loss around Implant-Retaining Overdentures versus Implant-Supported Fixed Prostheses 12-Month Follow-Up: A Retrospective Study.

Authors:  Odontuya Dorj; Chin-Kai Lin; Eisner Salamanca; Yu-Hwa Pan; Yi-Fan Wu; Yung-Szu Hsu; Jerry C-Y Lin; Hsi-Kuei Lin; Wei-Jen Chang
Journal:  Int J Environ Res Public Health       Date:  2022-02-03       Impact factor: 3.390

6.  Effect of implant macro-design on primary stability: A prospective clinical study.

Authors:  Naroa Lozano-Carrascal; Oscar Salomó-Coll; Marta Gilabert-Cerdà; Nuria Farré-Pagés; Jordi Gargallo-Albiol; Federico Hernández-Alfaro
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2016-03-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.