Literature DB >> 20064111

Impact on visual function from light scattering and glistenings in intraocular lenses, a long-term study.

Eva Mönestam1, Anders Behndig.   

Abstract

PURPOSE: To investigate the impact on visual function from light scattering and glistenings in intraocular lenses (IOLs) in patients who had cataract surgery 10 years previously.
SETTING: Eye clinic, Norrlands university hospital, Umeå, Sweden.
METHODS: One hundred and three patients, who had phacoemulsification with implantation of Acrysof(®) MA60BM IOLs 10 years previously, were evaluated with best corrected visual acuity (VA), and low contrast visual acuity (LCVA) 10% and 2.5%. The light scattering from the IOLs was measured by Scheimpflug photography. The degree of glistenings was also quantified at the slit-lamp. Eyes with coexisting pathology that could affect VA and LCVA were excluded.
RESULTS: The patients were divided into various groups according to the degree of light scattering and grade of glistenings. In two subsets of patients, paired data from the patients' eyes were analysed. It was not possible to detect any significant impact on visual function, best corrected visual acuity (BCVA) and LCVA 10% and 2.5% in eyes with a more pronounced light scattering or a higher grade of glistenings seen at the slit-lamp. The correlation between IOL dioptric power and both the total light scattering of the IOL, and the subjective grading of the intensity of the glistenings at the slit-lamp was statistically significant (r(P)=0.25; p=0.012; r(S)=0.23; p=0.019, respectively).
CONCLUSION: Most patients in this case series operated 10 years previously had severe glistenings and a high level of light scattering from their intraocular lenses. No detectable impact on BCVA, LCVA 10% and 2.5% was found.
© 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.

Entities:  

Mesh:

Year:  2010        PMID: 20064111     DOI: 10.1111/j.1755-3768.2009.01833.x

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  13 in total

1.  Effects of glistenings in intraocular lenses.

Authors:  Marrie van der Mooren; Luuk Franssen; Patricia Piers
Journal:  Biomed Opt Express       Date:  2013-07-11       Impact factor: 3.732

2.  Analysis of glistenings in hydrophobic acrylic intraocular lenses on visual performance.

Authors:  Lei Xi; Yi Liu; Feng Zhao; Chuan Chen; Bing Cheng
Journal:  Int J Ophthalmol       Date:  2014-06-18       Impact factor: 1.779

3.  Influence of surface light scattering in hydrophobic acrylic intraocular lenses on laser beam transmittance.

Authors:  Tomoyasu Shiraya; Satoshi Kato; Keiichiro Minami; Kazunori Miyata
Journal:  Int Ophthalmol       Date:  2016-05-24       Impact factor: 2.031

4.  Light scattering in intraocular lenses explanted 15 to 40 years after surgery.

Authors:  Jorge L Alio; Augusto Arias; Francesco D'Oria; Francesca Toto; Jorge Alio Del Barrio; Raul Duarte; Pablo Artal
Journal:  Biomed Opt Express       Date:  2021-05-18       Impact factor: 3.732

5.  Glistenings in hydrophobic acrylic intraocular lenses do affect visual function.

Authors:  George Hh Beiko; Andrzej Grzybowski
Journal:  Clin Ophthalmol       Date:  2013-11-27

6.  Influence of intraocular lens subsurface nanoglistenings on functional visual acuity.

Authors:  Takahiro Hiraoka; Kazunori Miyata; Takeshi Hayashidera; Masaharu Iida; Keita Takada; Keiichiro Minami; Tetsuro Oshika
Journal:  PLoS One       Date:  2017-03-22       Impact factor: 3.240

Review 7.  Biomaterial Influence on Intraocular Lens Performance: An Overview.

Authors:  Cari Pérez-Vives
Journal:  J Ophthalmol       Date:  2018-03-15       Impact factor: 1.909

8.  Evaluation of in vitro glistening formation in hydrophobic acrylic intraocular lenses.

Authors:  Brett E Thomes; Thomas A Callaghan
Journal:  Clin Ophthalmol       Date:  2013-07-25

9.  Decreased visual acuity resulting from glistening and sub-surface nano-glistening formation in intraocular lenses: A retrospective analysis of 5 cases.

Authors:  Hiroyuki Matsushima; Mayumi Nagata; Yoko Katsuki; Ichiro Ota; Kensaku Miyake; George H H Beiko; Andrzej Grzybowski
Journal:  Saudi J Ophthalmol       Date:  2015-07-29

10.  Long-term clinical results and scanning electron microscopic analysis of the aspheric, hydrophobic, acrylic intraocular lens CT LUCIA 611P(Y).

Authors:  Andreas F Borkenstein; Eva-Maria Borkenstein
Journal:  Clin Ophthalmol       Date:  2018-07-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.