Comparison of entrance and exit dose measurements using ionization chambers and silicon diodes.

S Heukelom1, J H Lanson, B J Mijnheer.   

Abstract

A high precision patient dosimetry method has been developed, based on the use of p-type diodes. First, entrance as well as exit dose calibration factors have to be determined under reference irradiation conditions. Secondly, a set of correction factors must be added for situations deviating from the reference conditions, i.e. for different source-skin distances, phantom (patient) thicknesses, field sizes or for insertion of a wedge into the photon beam. Finally some other detector characteristics such as the temperature dependence of the response have to be taken into account. For most irradiation conditions this procedure is sufficiently accurate to allow entrance as well as exist dose determinations with a diode to be in good agreement with dose values measured by an ionization chamber. The main factors effecting the value of the correction factors, the dependence of the diode sensitivity on the energy and the dose per pulse, have been investigated to explain some of the observed phenomena. Despite a strong energy dependence of the sensitivity, the correction factors are, for a particular type of diode, the same for 4 and 8 MV x-ray beams. The variation in the values for the correction factors with integrated dose received by the diode is small. These findings indicate that the correction factors, once available, can be applied under a number of circumstances. Due to the difference in behaviour of various diodes, even from the same batch, it is, however, necessary to determine the characteristics for each diode individually.

Entities:  

Mesh:

Year:  1991        PMID: 2006214     DOI: 10.1088/0031-9155/36/1/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  In vivo dosimetry using a single diode for megavoltage photon beam radiotherapy: implementation and response characterization.

Authors:  V C Colussi; A S Beddar; T J Kinsella; C H Sibata
Journal:  J Appl Clin Med Phys       Date:  2001       Impact factor: 2.102

2.  Calculation of exit dose for conformal and dynamically-wedged fields, based on water-equivalent path length measured with an amorphous silicon electronic portal imaging device.

Authors:  Awusi Kavuma; Martin Glegg; Mohamed Metwaly; Garry Currie; Alex Elliott
Journal:  J Appl Clin Med Phys       Date:  2011-03-03       Impact factor: 2.102

3.  Entrance dose measurements for in-vivo diode dosimetry: Comparison of correction factors for two types of commercial silicon diode detectors.

Authors:  X R Zhu
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

4.  Different intensity extension methods and their impact on entrance dose in breast radiotherapy: A study.

Authors:  A Sankar; J Velmurugan
Journal:  J Med Phys       Date:  2009-10

5.  In-vivo dose measurements with MOSFET dosimeters during MV portal imaging.

Authors:  Sathish Kumar; Rabi Raja Singh; Henry Finlay Godson; Retna Ponmalar; Paul Ravindran; Sunil Dutt Sharma; Subhashini John
Journal:  Rep Pract Oncol Radiother       Date:  2021-02-25
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.