Compact type-I coil planet centrifuge for counter-current chromatography.

Yi Yang1, Dongyu Gu, Yongqiang Liu, Haji Akber Aisa, Yoichiro Ito.   

Abstract

A compact type-I coil planet centrifuge has been developed for performing counter-current chromatography. It has a revolution radius of 10 cm and a column holder height of 5 cm compared with 37 and 50 cm in the original prototype, respectively. The reduction in the revolution radius and column length permits application of higher revolution speed and more stable balancing of the rotor which leads us to learn more about its performance and the future potential of type-I coil planet centrifuge. The chromatographic performance of this apparatus was evaluated in terms of retention of the stationary phase (S(f)), peak resolution (R(s)), theoretical plate (N) and peak retention time (t(R)). The results of the experiment indicated that increasing the revolution speed slightly improved both the retention of the stationary phase and the peak resolution while the separation time is remarkably shortened to yield an excellent peak resolution at a revolution speed of 800 rpm. With a 12 ml capacity coiled column, DNP-DL-glu, DNP-beta-ala and DNP-l-ala were resolved at R(s) of 2.75 and 2.16 within 90 min at a flow rate of 0.4 ml/min. We believe that the compact type-I coil planet centrifuge has a high analytical potential. Published by Elsevier B.V.

Entities:  

Mesh:

Year:  2010        PMID: 20060979      PMCID: PMC2815076          DOI: 10.1016/j.chroma.2009.12.055

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  6 in total

1.  Spiral Tube Assembly for High-Speed Countercurrent Chromatography: Choice of Elution Modes for Four Typical Two-Phase Solvent Systems.

Authors:  Y Ito; R Clary; J Powell; M Knight; T M Finn
Journal:  J Liq Chromatogr Relat Technol       Date:  2008-01-01       Impact factor: 1.312

2.  APPLICATION OF PREPARATIVE HIGH-SPEED COUNTERCURRENT CHROMATOGRAPHY FOR SEPARATION OF ELATINE FROM DELPHINIUM SHAWURENSE.

Authors:  Yi Yang; Dongyu Gu; Hankui Wu; Haji Akber Aisa; Tianyou Zhang; Yoichiro Ito
Journal:  J Liq Chromatogr Relat Technol       Date:  2008-01-01       Impact factor: 1.312

3.  Countercurrent chromatography with the flow-through coil planet centrifuge.

Authors:  Y Ito; R L Bowman
Journal:  J Chromatogr Sci       Date:  1973-06       Impact factor: 1.618

4.  Countercurrent chromatography with flow-through coil planet centrifuge.

Authors:  Y Ito; R L Bowman
Journal:  Science       Date:  1971-07-30       Impact factor: 47.728

5.  Flat-twisted tubing: novel column design for spiral high-speed counter-current chromatography.

Authors:  Yi Yang; Haji Akber Aisa; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2009-05-18       Impact factor: 4.759

6.  Novel Design for Centrifugal Countercurrent Chromatography: I. Zigzag Toroidal Column.

Authors:  Yi Yang; Haji Akber Aisa; Yoichiro Ito
Journal:  J Liq Chromatogr Relat Technol       Date:  2009-01-01       Impact factor: 1.312

  6 in total
  6 in total

1.  Evaluation on the performance of four different column models mounted on the compact type-I coil planet centrifuge.

Authors:  Yi Yang; Dongyu Gu; Haji Akber Aisa; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2010-10-26       Impact factor: 4.759

2.  Studies on the performance of different coiled column configurations for compact type-I countercurrent chromatography.

Authors:  Yi Yang; Dongyu Gu; Haji Akber Aisa; Yoichiro Ito
Journal:  J Sep Sci       Date:  2011-04-13       Impact factor: 3.645

3.  Evaluation of the effect of column orientation in type-I high-speed counter-current chromatography.

Authors:  Yi Yang; Dongyu Gu; Haji Akber Aisa; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2010-03-09       Impact factor: 4.759

Review 4.  Countercurrent Separation of Natural Products: An Update.

Authors:  J Brent Friesen; James B McAlpine; Shao-Nong Chen; Guido F Pauli
Journal:  J Nat Prod       Date:  2015-07-15       Impact factor: 4.050

5.  Partition efficiencies of newly fabricated universal high-speed counter-current chromatograph for separation of two different types of sugar derivatives with organic-aqueous two-phase solvent systems.

Authors:  Kazufusa Shinomiya; Kazuki Sato; Kazunori Yoshida; Koji Tokura; Hiroshi Maruyama; Kazuhiro Yanagidaira; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2013-11-05       Impact factor: 4.759

6.  A multilayer coil in type-I counter-current chromatography.

Authors:  Yi Yang; Jiao Yang; Chen Fang; Dongyu Gu; Ying Ma; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2018-02-13       Impact factor: 4.759

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.