A toolkit for the characterization of CCD cameras for transmission electron microscopy.

M Vulovic1, B Rieger, L J van Vliet, A J Koster, R B G Ravelli.   

Abstract

Charge-coupled devices (CCD) are nowadays commonly utilized in transmission electron microscopy (TEM) for applications in life sciences. Direct access to digitized images has revolutionized the use of electron microscopy, sparking developments such as automated collection of tomographic data, focal series, random conical tilt pairs and ultralarge single-particle data sets. Nevertheless, for ultrahigh-resolution work photographic plates are often still preferred. In the ideal case, the quality of the recorded image of a vitrified biological sample would solely be determined by the counting statistics of the limited electron dose the sample can withstand before beam-induced alterations dominate. Unfortunately, the image is degraded by the non-ideal point-spread function of the detector, as a result of a scintillator coupled by fibre optics to a CCD, and the addition of several inherent noise components. Different detector manufacturers provide different types of figures of merit when advertising the quality of their detector. It is hard for most laboratories to verify whether all of the anticipated specifications are met. In this report, a set of algorithms is presented to characterize on-axis slow-scan large-area CCD-based TEM detectors. These tools have been added to a publicly available image-processing toolbox for MATLAB. Three in-house CCD cameras were carefully characterized, yielding, among others, statistics for hot and bad pixels, the modulation transfer function, the conversion factor, the effective gain and the detective quantum efficiency. These statistics will aid data-collection strategy programs and provide prior information for quantitative imaging. The relative performance of the characterized detectors is discussed and a comparison is made with similar detectors that are used in the field of X-ray crystallography.

Mesh:

Year:  2009        PMID: 20057054     DOI: 10.1107/S0907444909031205

Source DB:  PubMed          Journal:  Acta Crystallogr D Biol Crystallogr        ISSN: 0907-4449


  4 in total

1.  Validation of the Mental Illness Sexual Stigma Questionnaire (MISS-Q) in a sample of Brazilian adults in psychiatric care.

Authors:  Milton Wainberg; Andrea Norcini Pala; Francine Cournos; Karen McKinnon
Journal:  J Bras Psiquiatr       Date:  2017 Jul-Sep

2.  Radiation damage in single-particle cryo-electron microscopy: effects of dose and dose rate.

Authors:  Manikandan Karuppasamy; Fatemeh Karimi Nejadasl; Milos Vulovic; Abraham J Koster; Raimond B G Ravelli
Journal:  J Synchrotron Radiat       Date:  2011-04-09       Impact factor: 2.616

3.  A posteriori correction of camera characteristics from large image data sets.

Authors:  Pavel Afanasyev; Raimond B G Ravelli; Rishi Matadeen; Sacha De Carlo; Gijs van Duinen; Bart Alewijnse; Peter J Peters; Jan-Pieter Abrahams; Rodrigo V Portugal; Michael Schatz; Marin van Heel
Journal:  Sci Rep       Date:  2015-06-11       Impact factor: 4.379

4.  Non-rigid image registration to reduce beam-induced blurring of cryo-electron microscopy images.

Authors:  Fatemeh Karimi Nejadasl; Manikandan Karuppasamy; Emily R Newman; John E McGeehan; Raimond B G Ravelli
Journal:  J Synchrotron Radiat       Date:  2012-11-29       Impact factor: 2.616

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.