Literature DB >> 20054934

Pull-out strength of sacral implants using Cotrel-Dubousset fixation devices.

F de Peretti1, J Benoliel, I Hovorka, P Eude, F Omar, C Aboulker, A Bourgeon, C Argenson.   

Abstract

Our aim was to determine the bone structure of the sacrum and the optimum location in the sacrum for the insertion of lumbosacral screws in osteosynthesis. Anatomical tests were performed on mortuary specimens at the Medical School in Nice, France, on frozen sections of sacrum and in computed tomographic (CT) sections with 3-dimensional reconstruction. Density assessment of different structures from the first and second sacral vertebrae (S1, S2) was performed and expressed in Hounsfield units. The ala and the lateral part of S1 contained yellow marrow forming a fatty mass bounded by the cortex of the sacroiliac joint at the linea terminalis and by the cancellous bone in the pedicles and the body of S1 and S2. These studies were undertaken prior to the experimental tests. The experimental tests were made using Cotrel-Dubousset instrumentation to determine the pull-out strength of sacral screws with a 7-mm diameter by assessing pull-out strengths of paired screws arranged either unilaterally with one screw in S1 and one in S2 or symmetrically to the left and right in S1. The devices demonstrating the best pull-out strength were the "corporopedicular" screw in S1 and the caudal lateral oblique screw in S1 passing through the sacroiliac joint. The paired screws with the best pull-out strength were those which included a corporopedicular screw in S1.

Mesh:

Year:  1992        PMID: 20054934     DOI: 10.1007/bf00301309

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  9 in total

1.  [Implanting an osteosynthesis screw in the first sacral vertebra].

Authors:  F De Peretti; C Argenson
Journal:  Presse Med       Date:  1991-06-01       Impact factor: 1.228

2.  Picture quality of computed tomography.

Authors:  G N Hounsfield
Journal:  AJR Am J Roentgenol       Date:  1976-07       Impact factor: 3.959

3.  Reduction and stabilization of grade IV spondylolisthesis.

Authors:  A D Steffee; D J Sitkowski
Journal:  Clin Orthop Relat Res       Date:  1988-02       Impact factor: 4.176

Review 4.  [Pars interarticularis reconstruction of spondylolysis using plates and screws with grafting without arthrodesis. Apropos of 78 cases].

Authors:  R Louis
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1988

5.  Computerized transverse axial scanning (tomography). 1. Description of system.

Authors:  G N Hounsfield
Journal:  Br J Radiol       Date:  1973-12       Impact factor: 3.039

6.  A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine.

Authors:  M R Zindrick; L L Wiltse; E H Widell; J C Thomas; W R Holland; B T Field; C W Spencer
Journal:  Clin Orthop Relat Res       Date:  1986-02       Impact factor: 4.176

7.  Segmental spine plates with pedicle screw fixation. A new internal fixation device for disorders of the lumbar and thoracolumbar spine.

Authors:  A D Steffee; R S Biscup; D J Sitkowski
Journal:  Clin Orthop Relat Res       Date:  1986-02       Impact factor: 4.176

8.  [A new technic for segmental spinal osteosynthesis using the posterior approach].

Authors:  Y Cotrel; J Dubousset
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1984

9.  A comparative biomechanical study of spinal fixation using Cotrel-Dubousset instrumentation.

Authors:  J P Farcy; M Weidenbaum; C B Michelsen; D A Hoeltzel; K A Athanasiou
Journal:  Spine (Phila Pa 1976)       Date:  1987-11       Impact factor: 3.468

  9 in total
  1 in total

1.  Opportunistic Computed Tomography and Spine Surgery: A Narrative Review.

Authors:  Matthew Shirley; Nathan Wanderman; Tony Keaveny; Paul Anderson; Brett A Freedman
Journal:  Global Spine J       Date:  2019-11-28
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.