Literature DB >> 180838

Picture quality of computed tomography.

G N Hounsfield.   

Abstract

Some limitations that impair the picture quality of computed tomography are presented. Picture grain is analyzed in detail and its relationship to different matrix sizes is demonstrated. The choices of matrix size for viewing various parts of the body are defined, and the need for higher resolution in the future is debated. Comparison is made between two scanning systems: the moving fan beam with rotation and the simple rotating fan beam. Possible artifacts in the picture caused by drift and delay in dector response are discussed.

Mesh:

Year:  1976        PMID: 180838     DOI: 10.2214/ajr.127.1.3

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  8 in total

1.  Mathematical aspects of divergent beam radiography.

Authors:  K T Smith; D C Solmon; S L Wagner; C Hamaker
Journal:  Proc Natl Acad Sci U S A       Date:  1978-05       Impact factor: 11.205

2.  Anatomic and experimental basis for the insertion of a screw at the first sacral vertebra.

Authors:  F de Peretti; C Argenson; A Bourgeon; F Omar; P Eude; C Aboulker
Journal:  Surg Radiol Anat       Date:  1991       Impact factor: 1.246

3.  Pull-out strength of sacral implants using Cotrel-Dubousset fixation devices.

Authors:  F de Peretti; J Benoliel; I Hovorka; P Eude; F Omar; C Aboulker; A Bourgeon; C Argenson
Journal:  Eur Spine J       Date:  1992-12       Impact factor: 3.134

4.  Radiation dose in neuroradiological procedures.

Authors:  I Isherwood; B R Pullan; R T Ritchings
Journal:  Neuroradiology       Date:  1978       Impact factor: 2.804

5.  Dynamic volume imaging of moving organs.

Authors:  R A Robb; L J Sinak; E A Hoffman; J H Kinsey; L D Harris; E L Ritman
Journal:  J Med Syst       Date:  1982-12       Impact factor: 4.460

Review 6.  The imaging of small pulmonary nodules.

Authors:  Zejun Zhou; Ping Zhan; Jiajia Jin; Yafang Liu; Qian Li; Chenhui Ma; Yingying Miao; Qingqing Zhu; Panwen Tian; Tangfeng Lv; Yong Song
Journal:  Transl Lung Cancer Res       Date:  2017-02

Review 7.  Quantitative evaluation of regional myocardial perfusion using fast X-ray computed tomography.

Authors:  A Schmermund; M R Bell; L O Lerman; E L Ritman; J A Rumberger
Journal:  Herz       Date:  1997-02       Impact factor: 1.443

Review 8.  Virtual anthropology - a brief review of the literature and history of computed tomography.

Authors:  Tanya Uldin
Journal:  Forensic Sci Res       Date:  2017-09-14
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.