Factors affecting short-term precision of musculoskeletal measures using peripheral quantitative computed tomography (pQCT).

R R Swinford1, S J Warden.   

Abstract

UNLABELLED: Few studies have investigated factors influencing the precision of peripheral quantitative computed tomography (pQCT) measures. This study found time between repeat scans and subject anthropometric characteristics to influence short-term precision of pQCT-derived measures in the lower leg. These findings have implications for both investigators and clinicians utilizing pQCT outcomes.
INTRODUCTION: Peripheral quantitative computed tomography (pQCT) is increasingly being used to investigate musculoskeletal changes associated with age, disease and/or intervention. Precision of pQCT measures is of paramount importance in this endeavor. This study aimed to establish the short-term precision of pQCT-derived musculoskeletal measures of the lower leg and investigate factors influencing this precision.
METHODS: Thirty healthy subjects had a series of six pQCT scans of the lower leg (66% of tibial length proximal from its distal end) performed on two separate days by two different testers. The influences of different testers, time between repeat scans, and subject anthropometric characteristics on precision were explored.
RESULTS: Overall precision error (root mean square) increased from bone (<1%) to muscle (<1.5%) to fat (3%). The two testers were equally precise in performing pQCT measures; however, precision error increased when repeat scans were repeated 1 week apart as opposed to on the same day. Subject anthropometric characteristics influenced precision errors with the general finding being that an increase in subject size was associated with less precise pQCT measures.
CONCLUSIONS: pQCT is a relatively precise technique for the assessment of bone and muscle, but precision is influenced by time between repeat scans and subject anthropometric characteristics. Investigators and clinicians need to be aware of these factors influencing pQCT outcomes as they may influence statistical power in clinical studies and the characterization of change in individual patients.

Entities:  

Mesh:

Year:  2010        PMID: 20052457     DOI: 10.1007/s00198-009-1151-3

Source DB:  PubMed          Journal:  Osteoporos Int        ISSN: 0937-941X            Impact factor:   4.507


  32 in total

1.  Monitoring skeletal changes by radiological techniques.

Authors:  C C Glüer
Journal:  J Bone Miner Res       Date:  1999-11       Impact factor: 6.741

2.  Bone-muscle strength indices for the human lower leg.

Authors:  J Rittweger; G Beller; J Ehrig; C Jung; U Koch; J Ramolla; F Schmidt; D Newitt; S Majumdar; H Schiessl; D Felsenberg
Journal:  Bone       Date:  2000-08       Impact factor: 4.398

3.  Minimum sample size requirements for bone density precision assessment produce inconsistency in clinical monitoring.

Authors:  W D Leslie; A Moayyeri
Journal:  Osteoporos Int       Date:  2006-08-10       Impact factor: 4.507

4.  Kinetics of human aging: I. Rates of senescence between ages 30 and 70 years in healthy people.

Authors:  M E Sehl; F E Yates
Journal:  J Gerontol A Biol Sci Med Sci       Date:  2001-05       Impact factor: 6.053

5.  Quantification of bone mineral density precision according to repositioning errors in peripheral quantitative computed tomography (pQCT) at the radius and tibia.

Authors:  L Sun; G Beller; D Felsenberg
Journal:  J Musculoskelet Neuronal Interact       Date:  2009 Jan-Mar       Impact factor: 2.041

6.  Bone density, structure, and strength in juvenile idiopathic arthritis: importance of disease severity and muscle deficits.

Authors:  Jon M Burnham; Justine Shults; Sarah E Dubner; Harjeet Sembhi; Babette S Zemel; Mary B Leonard
Journal:  Arthritis Rheum       Date:  2008-08

7.  Bone structure and volumetric BMD in overweight children: a longitudinal study.

Authors:  Rachel J Wetzsteon; Moira A Petit; Heather M Macdonald; Julie M Hughes; Thomas J Beck; Heather A McKay
Journal:  J Bone Miner Res       Date:  2008-12       Impact factor: 6.741

8.  Bone and muscle parameters of the tibia: agreement between the XCT 2000 and XCT 3000 instruments.

Authors:  Melonie Burrows; David M L Cooper; Danmei Liu; Heather A McKay
Journal:  J Clin Densitom       Date:  2008-11-11       Impact factor: 2.617

9.  Precision and intersite correlation of bone densitometry at the radius, tibia and femur with peripheral quantitative CT.

Authors:  O Groll; E M Lochmüller; M Bachmeier; J Willnecker; F Eckstein
Journal:  Skeletal Radiol       Date:  1999-12       Impact factor: 2.199

Review 10.  Precision assessment and radiation safety for dual-energy X-ray absorptiometry: position paper of the International Society for Clinical Densitometry.

Authors:  Sanford Baim; Charles R Wilson; E Michael Lewiecki; Marjorie M Luckey; Robert W Downs; Brian C Lentle
Journal:  J Clin Densitom       Date:  2005       Impact factor: 2.963

View more
  18 in total

1.  Short-term in vivo precision of BMD and parameters of trabecular architecture at the distal forearm and tibia.

Authors:  K Engelke; B Stampa; W Timm; B Dardzinski; A E de Papp; H K Genant; T Fuerst
Journal:  Osteoporos Int       Date:  2011-12-06       Impact factor: 4.507

2.  Role of endocortical contouring methods on precision of HR-pQCT-derived cortical micro-architecture in postmenopausal women and young adults.

Authors:  C E Kawalilak; J D Johnston; D M L Cooper; W P Olszynski; S A Kontulainen
Journal:  Osteoporos Int       Date:  2015-08-08       Impact factor: 4.507

3.  Monitoring time interval for pQCT-derived bone outcomes in postmenopausal women.

Authors:  R L Duckham; A W Frank; J D Johnston; W P Olszynski; S A Kontulainen
Journal:  Osteoporos Int       Date:  2013-01-24       Impact factor: 4.507

4.  Improving reliability of pQCT-derived muscle area and density measures using a watershed algorithm for muscle and fat segmentation.

Authors:  Andy Kin On Wong; Kayla Hummel; Cameron Moore; Karen A Beattie; Sami Shaker; B Catharine Craven; Jonathan D Adachi; Alexandra Papaioannou; Lora Giangregorio
Journal:  J Clin Densitom       Date:  2014-07-01       Impact factor: 2.617

5.  Precision of bone density and micro-architectural properties at the distal radius and tibia in children: an HR-pQCT study.

Authors:  C E Kawalilak; A T Bunyamin; K M Björkman; J D Johnston; S A Kontulainen
Journal:  Osteoporos Int       Date:  2017-09-18       Impact factor: 4.507

6.  Dietary inflammatory index® and cortical bone outcomes in healthy adolescent children.

Authors:  L M Coheley; N Shivappa; J R Hebert; R D Lewis
Journal:  Osteoporos Int       Date:  2019-05-29       Impact factor: 4.507

7.  Peripheral Quantitative Computed Tomography Predicts Humeral Diaphysis Torsional Mechanical Properties With Good Short-Term Precision.

Authors:  Alyssa M Weatherholt; Keith G Avin; Andrea L Hurd; Jacob L Cox; Scott T Marberry; Brandon G Santoni; Stuart J Warden
Journal:  J Clin Densitom       Date:  2014-11-08       Impact factor: 2.617

8.  Racial differences in cortical bone and their relationship to biochemical variables in Black and White children in the early stages of puberty.

Authors:  S J Warden; K M Hill; A J Ferira; E M Laing; B R Martin; D B Hausman; C M Weaver; M Peacock; R D Lewis
Journal:  Osteoporos Int       Date:  2012-10-24       Impact factor: 4.507

Review 9.  Quantitative imaging techniques for the assessment of osteoporosis and sarcopenia.

Authors:  Sara Guerri; Daniele Mercatelli; Maria Pilar Aparisi Gómez; Alessandro Napoli; Giuseppe Battista; Giuseppe Guglielmi; Alberto Bazzocchi
Journal:  Quant Imaging Med Surg       Date:  2018-02

10.  Serum 25-Hydroxyvitamin D and Intact Parathyroid Hormone Influence Muscle Outcomes in Children and Adolescents.

Authors:  Christian S Wright; Emma M Laing; Norman K Pollock; Dorothy B Hausman; Connie M Weaver; Berdine R Martin; George P McCabe; Munro Peacock; Stuart J Warden; Kathleen M Hill Gallant; Richard D Lewis
Journal:  J Bone Miner Res       Date:  2018-08-27       Impact factor: 6.741