Literature DB >> 20052127

Spectroscopic measurements with dispersion encoded full range frequency domain optical coherence tomography in single- and multilayered non-scattering phantoms.

B Hermann1, B Hofer, C Meier, W Drexler.   

Abstract

In this study, depth resolved measurements of absorption profiles in the wavelength range of 800 nm with a bandwidth of 140 nm are demonstrated using high speed spectroscopic frequency domain OCT(SOCT) and a full range reconstruction algorithm (dispersion encoded full range, DEFR). The feasibility of the algorithm for SOCT is tested in simulation and experiment. With proper calibration, SOCT with DEFR is able to extract absolute, depth resolved absorption profiles over the whole wavelength range at once without the need of tuning and performing measurements at single wavelengths sequentially. The superior acquisition speed and better phase stability in frequency domain as compared to time domain results in a better reproducibility and practicability for spectroscopic measurements. In addition, high acquisition speed in excess of 20 kHz allows to measure absorption dynamics with 50 micros time resolution, which might be useful for the investigation of pharmacokinetics or pharmacodynamics. SOCT of approximately 600 microm thick single- and multilayered, weakly scattering phantoms with varying absorption in the range of 5-80 cm(-1), equivalent to blood absorption in capillaries, is presented. SOCT measurements are compared with those using a spectrometer in transmission mode. For Indocyanine Green (ICG), a dynamic absorption measurements are demonstrated.

Entities:  

Mesh:

Year:  2009        PMID: 20052127     DOI: 10.1364/OE.17.024162

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  3 in total

1.  Comparison of different metrics for analysis and visualization in spectroscopic optical coherence tomography.

Authors:  Volker Jaedicke; Semih Agcaer; Francisco E Robles; Marian Steinert; David Jones; Sebastian Goebel; Nils C Gerhardt; Hubert Welp; Martin R Hofmann
Journal:  Biomed Opt Express       Date:  2013-11-22       Impact factor: 3.732

2.  Separating the scattering and absorption coefficients using the real and imaginary parts of the refractive index with low-coherence interferometry.

Authors:  Francisco E Robles; Adam Wax
Journal:  Opt Lett       Date:  2010-09-01       Impact factor: 3.776

3.  Multimodal photoacoustic and optical coherence tomography scanner using an all optical detection scheme for 3D morphological skin imaging.

Authors:  Edward Z Zhang; Boris Povazay; Jan Laufer; Aneesh Alex; Bernd Hofer; Barbara Pedley; Carl Glittenberg; Bradley Treeby; Ben Cox; Paul Beard; Wolfgang Drexler
Journal:  Biomed Opt Express       Date:  2011-07-08       Impact factor: 3.732

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.