Literature DB >> 17956568

Root contact during insertion of miniscrews for orthodontic anchorage increases the failure rate: an animal study.

Yuan-Hou Chen1, Hao-Hueng Chang, Yi-Jane Chen, David Lee, Hsien-Hsiung Chiang, Chung-Chen Jane Yao.   

Abstract

OBJECTIVES: Miniscrews and miniplates are increasingly being used for absolute anchorage during orthodontic treatment. However, potential problems of damaging adjacent roots and their consequences during mini-implant placement in the alveolar process have not been clearly described.
MATERIALS AND METHODS: Animal experiments were used to evaluate the stability of miniscrews placed with intentional root contact. The root repair was evaluated after screw removal. Seventy-two miniscrews were surgically placed in the mandibular alveolar bone of six adult mongrel dogs with metabolic bone labeling at 3-week intervals. Miniscrews of the experimental group were placed so that they contacted the root of the adjacent teeth, were retained for different time durations, and were then removed. The insertion torque, clinical measurements, removal torque, and histological findings were analyzed.
RESULTS: (1) miniscrews contacting the roots showed a significantly higher insertion torque than those without contact; (2) there was a significant difference in the removal torque measurements based on the mobility of miniscrews and the state of root contact; and (3) miniscrews contacting the root were at greater risk of failure.
CONCLUSIONS: During placement of miniscrews in the aveolar process, increased failure rates were noticed among those contacting adjacent roots. Failed miniscrews appeared to be surrounded with a greater volume of soft tissue. When more inflammation was present, the adjacent roots seemed to experience more resorption. Nevertheless, the created lesion was repaired with a narrow zone of mineralized tissue deposited on the root surface, which was likely cellular cementum, and was mainly filled with alveolar bone, with the periodontal ligament space being maintained.

Entities:  

Mesh:

Year:  2007        PMID: 17956568     DOI: 10.1111/j.1600-0501.2007.01418.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  20 in total

1.  Effect of loaded orthodontic miniscrew implant on compressive stresses in adjacent periodontal ligament.

Authors:  Mhd Hassan Albogha; Ichiro Takahashi
Journal:  Angle Orthod       Date:  2018-09-19       Impact factor: 2.079

2.  An interview with Benedict Wilmes.

Authors:  Guilherme Thiesen; Marcus Vinícius Neiva Nunes do Rego; Jorge Faber; Ki Beom Kim
Journal:  Dental Press J Orthod       Date:  2016 Nov-Dec

3.  Mechanical stability assessment of novel orthodontic mini-implant designs: Part 2.

Authors:  Christine Hong; Peter Truong; Ha Na Song; Benjamin M Wu; Won Moon
Journal:  Angle Orthod       Date:  2011-06-29       Impact factor: 2.079

4.  Healing of root and surrounding periodontium after root damage with miniscrew implants: a histomorphologic study in dogs.

Authors:  Yingtao Lv; Zhaoqiang Zhang; Yuan Su; Peiyan Yuan; Weiqun Ma; Wenhua Huang; Pingping Xu
Journal:  Clin Oral Investig       Date:  2017-08-31       Impact factor: 3.573

5.  Comparison of skeletal and conventional anchorage methods in conjunction with pre-operative decompensation of a skeletal class III malocclusion.

Authors:  Benedict Wilmes; Gudrun Olthoff; Dieter Drescher
Journal:  J Orofac Orthop       Date:  2009-08-02       Impact factor: 1.938

6.  Multipurpose use of orthodontic mini-implants to achieve different treatment goals.

Authors:  M Nienkemper; B Wilmes; A Pauls; D Drescher
Journal:  J Orofac Orthop       Date:  2012-10-28       Impact factor: 1.938

7.  Root and bone response to the proximity of a mini-implant under orthodontic loading.

Authors:  Yang-Ku Lee; Jong-Wan Kim; Seung-Hak Baek; Tae-Woo Kim; Young-Il Chang
Journal:  Angle Orthod       Date:  2010-05       Impact factor: 2.079

8.  Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: protocol for a systematic review.

Authors:  Reint Meursinge Reynders; Luisa Ladu; Laura Ronchi; Nicola Di Girolamo; Jan de Lange; Nia Roberts; Annette Plüddemann
Journal:  Syst Rev       Date:  2015-04-02

Review 9.  Systematic review of mini-implant displacement under orthodontic loading.

Authors:  Manuel Nienkemper; Jörg Handschel; Dieter Drescher
Journal:  Int J Oral Sci       Date:  2013-12-20       Impact factor: 6.344

10.  Effects of insertion angle and implant thread type on the fracture properties of orthodontic mini-implants during insertion.

Authors:  Il-Sik Cho; Tae-Woo Kim; Sug-Joon Ahn; Il-Hyung Yang; Seung-Hak Baek
Journal:  Angle Orthod       Date:  2012-12-10       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.