Literature DB >> 20049960

Coronary intervention with 4-French catheters.

Satoshi Takeshita1, Shinji Tanaka, Shigeru Saito.   

Abstract

OBJECTIVES: We sought to determine whether 4-Fr percutaneous coronary intervention (PCI) is associated with technical difficulties that might have an unfavorable impact on procedural parameters.
BACKGROUND: Four-Fr PCI is often associated with difficulties in catheter manipulation, which may lead to greater time consumption and increased dye usage when compared with PCI employing larger guiding catheters.
METHODS: From July 2007 to March 2009, 62 patients underwent 4-Fr PCI. Procedural characteristics were compared between patients who underwent 4-Fr PCI in 2007 (early phase: 31 lesions in 26 patients) and those underwent in 2008 or later (later phase: 40 lesions in 36 patients).
RESULTS: Ad-hoc coronary intervention (3% vs. 23%, P < 0.05) and deep-vessel intubation (46% vs. 91%, P < 0.05) were observed less frequently in the late phase than the early phase. Fluoroscopy time (8 +/- 6 min vs. 17 +/- 15 min, P < 0.05) and the amount of contrast dye used (64 +/- 33 mL vs. 90 +/- 46 mL, P < 0.05) were significantly reduced in the late phase than the early phase. No access site-related complications were observed in patients in either phase.
CONCLUSIONS: The performance of 4-Fr PCI requires a certain learning curve, following which a reduction in fluoroscopy time and use of contrast dye may be achieved. This improvement in procedural parameters and the low incidence of access site-related complications might allow 4-Fr PCI to serve as a minimally invasive approach for the treatment of coronary artery diseases. (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20049960     DOI: 10.1002/ccd.22308

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  2 in total

1.  Impact of contrast agent viscosity on coronary balloon deflation times: bench testing results.

Authors:  Owen Mogabgab; Vishal G Patel; Tesfaldet T Michael; Anna Kotsia; George Christopoulos; Subhash Banerjee; Emmanouil S Brilakis
Journal:  J Interv Cardiol       Date:  2014-01-23       Impact factor: 2.279

2.  Evaluation of the usefulness of coronary catheters and 4 Fr insertion sets for transradial access coronarography in comparison with catheters and 5 Fr sets.

Authors:  Piotr Chodór; Stanisław Morawski; Sylwia Sulik-Gajda; Nela Ramus; Jacek Kowalczyk; Grzegorz Honisz; Krzysztof Wilczek; Beata Sredniawa; Zbigniew Kalarus
Journal:  Postepy Kardiol Interwencyjnej       Date:  2013-11-18       Impact factor: 1.426

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.