Literature DB >> 20047196

Ultrasonographic prediction of homozygous alpha0-thalassemia using placental thickness, fetal cardiothoracic ratio and middle cerebral artery Doppler: alone or in combination?

K Y Leung1, K B Cheong, C P Lee, V Chan, Y H Lam, M Tang.   

Abstract

OBJECTIVE: To compare the predictive values of three ultrasonographic parameters: placental thickness (PT), fetal cardiothoracic ratio (CTR) and middle cerebral artery peak systolic velocity (MCA-PSV), alone or in combination, in pregnancies affected by homozygous alpha(0)-thalassemia at 12-20 weeks' gestation.
METHODS: Pregnant women at risk of carrying a fetus affected by homozygous alpha(0)-thalassemia were studied from 1995 to 2006 using serial ultrasonography at 12-15 weeks, 16-20 weeks and 30 weeks' gestation. We measured CTR and PT from 1995, and MCA-PSV as well from 1997. An invasive prenatal test was offered if cardiomegaly with or without placentomegaly was detected but the MCA-PSV results were used only retrospectively for analysis.
RESULTS: Of a total of 777 at-risk fetuses studied, 138 (17.8%) were affected by homozygous alpha(0)-thalassemia. At 12-15 weeks' gestation, 598 ultrasound examinations were performed. CTR was better than both PT and MCA-PSV in the prediction of affected pregnancies. The highest sensitivity (98.3%) was achieved by the combination of CTR and/or MCA-PSV at a false-positive rate of 15.8%. At 16-20 weeks' gestation, 410 ultrasound examinations were performed, 121 of which were at the patient's first visit and 289 of which were at a follow-up visit. Both CTR and MCA-PSV predicted the affected pregnancies equally well. The sensitivity of CTR was 100.0%, but the false-positive rate was 5.2%. In contrast, the false-positive rate of MCA-PSV alone was 1.4% and that of the combination of CTR and MCA-PSV was 0%, although their sensitivities were less than 65%.
CONCLUSIONS: The data suggest that adding MCA-PSV to CTR in the prediction of homozygous alpha(0)-thalassemia can increase the sensitivity at 12-15 weeks and decrease the false-positive rate at 16-20 weeks' gestation.

Entities:  

Mesh:

Year:  2010        PMID: 20047196     DOI: 10.1002/uog.7443

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  3 in total

1.  Screening for hemoglobin Bart's disease among fetuses at risk at mid-pregnancy using the fetal cardiac diameter to biparietal diameter ratio.

Authors:  Nopamas Thathan; Kuntharee Traisrisilp; Suchaya Luewan; Kasemsri Srisupundit; Fuanglada Tongprasert; Theera Tongsong
Journal:  BMC Pregnancy Childbirth       Date:  2014-07-16       Impact factor: 3.007

Review 2.  Foetal haemodynamic response to anaemia.

Authors:  Keooudone Thammavong; Suchaya Luewan; Phudit Jatavan; Theera Tongsong
Journal:  ESC Heart Fail       Date:  2020-09-10

3.  Comment on Fetal Gestational Age Determination Using Ultrasound Placental Thickness.

Authors:  Rujittika Mungmunpuntipantip; Viroj Wiwanitkit
Journal:  J Med Ultrasound       Date:  2022-03-23
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.