Literature DB >> 20039134

Optimization of MR phase-contrast-based flow velocimetry and shear stress measurements.

Taeho Kim1, Ji-Hyea Seo, Seong-Sik Bang, Hyeon-Woo Choi, Yongmin Chang, Jongmin Lee.   

Abstract

This study was designed to measure the pixel-by-pixel flow velocity and shear stress from phase-contrast MR images. An optimized method was suggested and the use of the method was confirmed. A self-developed, straight steady flow model system was scanned by MRI with a velocity-encoded phase-contrast sequence. In-house developed software was used for the pixel-by-pixel flow velocity and shear stress measurements and the measurements were compared with physically measured mean velocity and shear stress. A comparison between the use of the in-house velocimetry software and a commercial velocimetry system was also performed. Curved steady flow models were scanned by phase-contrast MRI. Subsequently, velocity and shear stress were measured to confirm the shifted peak flow velocity and shear stress toward the outer side of the lumen. Peak velocity and shear stress were calculated for both the inner and outer half of the lumen and were statistically compared. The mean velocity measured with the use of in-house software had a significant correlation with the physical measurements of mean velocity; in addition, the measurement was more precise compared to the commercial system (R(2) = 0.85 vs. 0.75, respectively). The calculated mean shear stress had a significant correlation with the physical measurements of mean shear stress (R(2) = 0.95). The curved flow model showed a significantly shifted peak velocity and shear stress zones toward the outside of the flow (P < 0.0001). The technique to measure pixel-by-pixel velocity and shear stress of steady flow from velocity-encoded phase-contrast MRI was optimized. This technique had a good correlation with physical measurements and was superior to a commercially available system.

Mesh:

Year:  2009        PMID: 20039134     DOI: 10.1007/s10554-009-9572-9

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  17 in total

Review 1.  Quantification of flow dynamics in congenital heart disease: applications of velocity-encoded cine MR imaging.

Authors:  Gita A Varaprasathan; Philip A Araoz; Charles B Higgins; Gautham P Reddy
Journal:  Radiographics       Date:  2002 Jul-Aug       Impact factor: 5.333

Review 2.  Applications of phase-contrast flow and velocity imaging in cardiovascular MRI.

Authors:  Peter D Gatehouse; Jennifer Keegan; Lindsey A Crowe; Sharmeen Masood; Raad H Mohiaddin; Karl-Friedrich Kreitner; David N Firmin
Journal:  Eur Radiol       Date:  2005-07-08       Impact factor: 5.315

3.  Preliminary study of hemodynamics in human carotid bifurcation by computational fluid dynamics combined with magnetic resonance angiography.

Authors:  Yunjing Xue; Peyi Gao; Yan Lin; Chengbo Dai
Journal:  Acta Radiol       Date:  2007-09       Impact factor: 1.990

Review 4.  Detection and quantification of valvular heart disease with dynamic cardiac MR imaging.

Authors:  D Didier; O Ratib; R Lerch; B Friedli
Journal:  Radiographics       Date:  2000 Sep-Oct       Impact factor: 5.333

5.  Quantitative flow measurement in phase contrast MR angiography.

Authors:  M F Walker; S P Souza; C L Dumoulin
Journal:  J Comput Assist Tomogr       Date:  1988 Mar-Apr       Impact factor: 1.826

6.  Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress.

Authors:  D N Ku; D P Giddens; C K Zarins; S Glagov
Journal:  Arteriosclerosis       Date:  1985 May-Jun

Review 7.  Velocity-encoded cine MR imaging in aortic coarctation: functional assessment of hemodynamic events.

Authors:  Jeffrey J Hom; Karen Ordovas; Gautham P Reddy
Journal:  Radiographics       Date:  2008 Mar-Apr       Impact factor: 5.333

Review 8.  Vascular fluid mechanics, the arterial wall, and atherosclerosis.

Authors:  R M Nerem
Journal:  J Biomech Eng       Date:  1992-08       Impact factor: 2.097

Review 9.  Diabetes and atherosclerosis: an epidemiologic view.

Authors:  K Pyörälä; M Laakso; M Uusitupa
Journal:  Diabetes Metab Rev       Date:  1987-04

10.  Estimation of arterial stiffness, compliance, and distensibility from M-mode ultrasound measurements of the common carotid artery.

Authors:  G Gamble; J Zorn; G Sanders; S MacMahon; N Sharpe
Journal:  Stroke       Date:  1994-01       Impact factor: 7.914

View more
  3 in total

Review 1.  Cardiovascular imaging 2010 in the International Journal of Cardiovascular Imaging.

Authors:  Ricardo A Costa; Johan H C Reiber; Frank J Rybicki; Paul Schoenhagen; Arthur A Stillman; Johan de Sutter; Nico R L van de Veire; Ernst E van der Wall
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-24       Impact factor: 2.357

2.  Screening for subclinical atherosclerosis by noninvasive methods in asymptomatic patients with risk factors.

Authors:  Xavier Castellon; Vera Bogdanova
Journal:  Clin Interv Aging       Date:  2013-05-28       Impact factor: 4.458

Review 3.  Image-Based Evaluation of Vascular Function and Hemodynamics.

Authors:  Jongmin Lee
Journal:  Pulse (Basel)       Date:  2013-09-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.