Literature DB >> 18349448

Velocity-encoded cine MR imaging in aortic coarctation: functional assessment of hemodynamic events.

Jeffrey J Hom1, Karen Ordovas, Gautham P Reddy.   

Abstract

Velocity-encoded cine magnetic resonance (MR) imaging is becoming the modality of choice for the clinical evaluation of aortic coarctation, a congenital narrowing of the thoracic aorta, in which a functional assessment of hemodynamic obstruction is as important as anatomic delineation. A flow-sensitive phase-contrast technique, velocity-encoded cine MR imaging is based on the principle that moving protons change phase in proportion to their velocity. Because it enables precise hemodynamic characterization, the technique is especially useful for evaluating the severity of aortic coarctation. By enabling a qualitative assessment of the presence and direction of collateral circulation, velocity-encoded cine MR imaging provides information about the presence and severity of obstruction. It also allows accurate quantitation of key hemodynamic parameters such as flow velocity, flow volume, and pressure gradients across the coarctation-functional information that is clinically useful for both preoperative planning and postinterventional monitoring. The results of recent experience indicate that velocity-encoded cine MR imaging also may be applicable for the detection of recurrent stenosis after stent placement or angioplasty. (c) RSNA, 2008

Entities:  

Mesh:

Year:  2008        PMID: 18349448     DOI: 10.1148/rg.282075705

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  21 in total

Review 1.  Imaging of thoracic aortic disease.

Authors:  B J Holloway; D Rosewarne; R G Jones
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

2.  [MRI for therapy control in patients with aortic isthmus stenosis].

Authors:  B J Wintersperger; D Theisen; M F Reiser
Journal:  Radiologe       Date:  2011-01       Impact factor: 0.635

Review 3.  The role of MRI and CT in congenital heart disease.

Authors:  Rajesh Krishnamurthy
Journal:  Pediatr Radiol       Date:  2009-04

4.  Fetal blood flow velocimetry by phase-contrast MRI using a new triggering method and comparison with Doppler ultrasound in a sheep model: a pilot study.

Authors:  Bjoern P Schoennagel; Chressen C Remus; Jin Yamamura; Fabian Kording; Manuela Tavares de Sousa; Manuela Tavares de Sousa; Kurt Hecher; Roland Fischer; Friedrich Ueberle; Matthias Boehme; Gerhard Adam; Hendrik Kooijman; Ulrike Wedegaertner
Journal:  MAGMA       Date:  2013-08-10       Impact factor: 2.310

5.  Optimization of MR phase-contrast-based flow velocimetry and shear stress measurements.

Authors:  Taeho Kim; Ji-Hyea Seo; Seong-Sik Bang; Hyeon-Woo Choi; Yongmin Chang; Jongmin Lee
Journal:  Int J Cardiovasc Imaging       Date:  2009-12-29       Impact factor: 2.357

6.  Iatrogenic neonatal type B aortic dissection: comprehensive MRI-based diagnosis and follow-up.

Authors:  Julia Geiger; M Markl; B Stiller; C Schlensak; R Arnold
Journal:  Pediatr Radiol       Date:  2011-06-15

7.  [Clinical indications for the use of cardiac MRI. By the SIRM Study Group on Cardiac Imaging].

Authors:  E Di Cesare; F Cademartiri; I Carbone; A Carriero; M Centonze; F De Cobelli; R De Rosa; P Di Renzi; A Esposito; R Faletti; R Fattori; M Francone; A Giovagnoni; L La Grutta; G Ligabue; L Lovato; R Marano; M Midiri; A Romagnoli; V Russo; F Sardanelli; L Natale; J Bogaert; A De Roos
Journal:  Radiol Med       Date:  2012-11-26       Impact factor: 3.469

8.  Coarctation of the aorta: management, indications for intervention, and advances in care.

Authors:  Mohammed Haris Umer Usman; Pablo Rengifo-Moreno; Sean F Janzer; Ignacio Inglessis-Azuaje; Christian Witzke-Sanz
Journal:  Curr Treat Options Cardiovasc Med       Date:  2014-10

9.  MRI assessment of thoracic stent grafts after emergency implantation in multi trauma patients: a feasibility study.

Authors:  Volker Rasche; Alexander Oberhuber; Stephan Trumpp; Axel Bornstedt; Karl-Heinz Orend; Nico Merkle; Wolfgang Rottbauer; Martin Hoffmann
Journal:  Eur Radiol       Date:  2011-02-18       Impact factor: 5.315

Review 10.  Noninvasive Imaging of Flow and Vascular Function in Disease of the Aorta.

Authors:  Matthew C Whitlock; W Gregory Hundley
Journal:  JACC Cardiovasc Imaging       Date:  2015-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.