Literature DB >> 20037829

Clinical value of stereoscopic three-dimensional echocardiography in assessment of atrial septal defects: feasibility and efficiency.

Jing Wang1, Xinfang Wang, Mingxing Xie, Lin He, Qing Lv, Lei Wang.   

Abstract

Stereoscopic three-dimensional echocardiography(S-3DE) is a novel displaying technology based on real-time 3-dimensional echocardiography (RT-3DE). Our study was to evaluate the feasibility and efficiency of S-3DE in the diagnosis of atrial septal defect (ASD) and its use in the guidance for transcatheter ASD occlusion. Twelve patients with secundum ASD underwent RT-3DE examination and 9 of the 12 were subjected to transcatheter closure of ASD. Stereoscopic vision was generated with a high-performance volume renderer with red-green stereoscopic glasses. S-3DE was compared with standard RT-3D display for the assessment of the shape, size, and the surrounding tissues of ASD and for the guidance of ASD occlusion. The appearance rate of coronary sinus and the mean formation time of the IVC, SVC were compared. Our results showed that S-3DE could measure the diameter of ASD accurately and there was no significant difference in the measurements between S-3DE and standard 3D display (2.89+/-0.73 cm vs 2.85+/-0.72 cm, P>0.05; r=0.96, P<0.05). The appearance of coronary sinus for S-3DE was higher as compared with the standard 3D display (93.3% vs 100%). The mean time of the IVC, SVC for S-3DE monitor was slightly shorter than that of the standard 3D display (11.0+/-3.8 s vs 10.3+/-3.6 s, P>0.05). The mean completion time of interventional procedure was shortened with S-3DE display as compared with standard 3D display (17.3+/-3.1 min vs 23.0+/-3.9 min, P<0.05). Stereoscopic three-dimensional echocardiography could improve the visualization of three-dimensional echocardiography, facilitate the identification of the adjacent structures, decrease the time required for interventional manipulation. It may be a feasible, safe, and efficient tool for guiding transcatheter septal occlusion or the surgical interventions.

Entities:  

Mesh:

Year:  2009        PMID: 20037829     DOI: 10.1007/s11596-009-0624-0

Source DB:  PubMed          Journal:  J Huazhong Univ Sci Technolog Med Sci        ISSN: 1672-0733


  14 in total

1.  Live three-dimensional echo--a major incremental step in the development of cardiac ultrasound.

Authors:  Edward A Gill
Journal:  J Cardiovasc Manag       Date:  2003 Mar-Apr

2.  Optimization of ASD assessment using real time three-dimensional transesophageal echocardiography.

Authors:  Adam Skolnick; Eleni Vavas; Itzhak Kronzon
Journal:  Echocardiography       Date:  2009-02       Impact factor: 1.724

Review 3.  Real-time transesophageal three-dimensional echocardiography for guidance of percutaneous cardiac interventions: first experience.

Authors:  Jan Balzer; Harald Kühl; Tienush Rassaf; Rainer Hoffmann; Patrick Schauerte; Malte Kelm; Andreas Franke
Journal:  Clin Res Cardiol       Date:  2008-05-29       Impact factor: 5.460

Review 4.  Real-time three-dimensional echocardiography: an update.

Authors:  Michele Correale; Riccardo Ieva; Matteo Di Biase
Journal:  Eur J Intern Med       Date:  2008-04-02       Impact factor: 4.487

5.  Transcatheter closure of multiple atrial septal defects. Initial results and value of two- and three-dimensional transoesophageal echocardiography.

Authors:  Q Cao; W Radtke; F Berger; W Zhu; Z M Hijazi
Journal:  Eur Heart J       Date:  2000-06       Impact factor: 29.983

6.  Real-time 3-dimensional echocardiography in assessing atrial and ventricular septal defects: an echocardiographic-surgical correlative study.

Authors:  Tsung O Cheng; Ming-Xing Xie; Xin-Fang Wang; Ying Wang; Qing Lu
Journal:  Am Heart J       Date:  2004-12       Impact factor: 4.749

7.  Three-dimensional echocardiography-guided beating-heart surgery without cardiopulmonary bypass: a feasibility study.

Authors:  Yoshihiro Suematsu; Gerald R Marx; Jeffrey A Stoll; Pierre E DuPont; Robin O Cleveland; Robert D Howe; John K Triedman; Tomislav Mihaljevic; Bassem N Mora; Bernie J Savord; Ivan S Salgo; Pedro J del Nido
Journal:  J Thorac Cardiovasc Surg       Date:  2004-10       Impact factor: 5.209

8.  Stereoscopic vision display technology in real-time three-dimensional echocardiography-guided intracardiac beating-heart surgery.

Authors:  Nikolay V Vasilyev; Paul M Novotny; Joseph F Martinez; Hugo Loyola; Ivan S Salgo; Robert D Howe; Pedro J del Nido
Journal:  J Thorac Cardiovasc Surg       Date:  2008-05-02       Impact factor: 5.209

9.  Intracardiac echocardiographic guidance during transcatheter device closure of atrial septal defect and patent foramen ovale.

Authors:  Michael G Earing; Allison K Cabalka; James B Seward; Charles J Bruce; Guy S Reeder; Donald J Hagler
Journal:  Mayo Clin Proc       Date:  2004-01       Impact factor: 7.616

10.  Usefulness of intraoperative real-time 3D transesophageal echocardiography in cardiac surgery.

Authors:  Thierry V Scohy; Folkert J Ten Cate; Patrick V E L Lecomte; Jackie McGhie; Peter L de Jong; Jan Hofland; Ad J J C Bogers
Journal:  J Card Surg       Date:  2008 Nov-Dec       Impact factor: 1.620

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.