Torque-fitting and resonance frequency analyses of implants in conventional sockets versus controlled bone defects in vitro.

K Akça1, A M Kökat, A Cömert, M Akkocaoğlu, I Tekdemir, M C Cehreli.   

Abstract

The primary stability of implants should be high on insertion into fresh extraction sockets. Torque-fitting and resonance frequency analyses (RFA) are used to assess primary implant anchorage and stability. The torque-fitting and RFA of implants placed in conventional surgical sockets and sockets with controlled coronal bone defects was compared. The possible relation between torque-fitting and RFA was explored. Ø 3.3 mm x 12 mm implants were placed in 16 sockets finalized with Ø 2.8mm surgical pilot drills in the right iliac crests of two fresh cadavers (control). In the test group, implants were placed into sockets prepared by Ø 2.8mm drill followed by Ø 4.2mm twist drills to a depth of 6mm to create circumferential controlled coronal bone defects (50% bone loss). Primary implant stability was assessed using insertion torque values (ITV) followed by RFA. Mean ITV and RFA measurements for test groups (7.83+/-0.91 N cm and 40.88+/-3.57) were significantly lower than controls (14.80+/-1 N cm and 66.31+/-0.9) (P<0.05). Reductions of ITV and RFA measurements in relation to bone defect were 47% and 38%. The existence of controlled bone defects eliminating contact coronally leads to decrease in torque-fitting and primary stability of implants. No relationship was observed between torque-fitting and RFA. Copyright 2009 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20036107     DOI: 10.1016/j.ijom.2009.11.019

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  3 in total

1.  Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants.

Authors:  Yahya Açil; Jan Sievers; Aydin Gülses; Mustafa Ayna; Jörg Wiltfang; Hendrik Terheyden
Journal:  Odontology       Date:  2016-08-18       Impact factor: 2.634

2.  The influence of bone graft procedures on primary stability and bone change of implants placed in fresh extraction sockets.

Authors:  Sang Ho Jun; Chang-Joo Park; Suk-Hyun Hwang; Youn Ki Lee; Cong Zhou; Hyon-Seok Jang; Jae-Jun Ryu
Journal:  Maxillofac Plast Reconstr Surg       Date:  2018-04-25

3.  Clinical Relevance of Bone Density Values from CT Related to Dental Implant Stability: A Retrospective Study.

Authors:  Vincenzo Bruno; Cesare Berti; Carlo Barausse; Mauro Badino; Roberta Gasparro; Daniela Rita Ippolito; Pietro Felice
Journal:  Biomed Res Int       Date:  2018-05-31       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.