Literature DB >> 20035602

Effect of erbium-doped yttrium aluminium garnet laser parameters on ablation capacity and morphology of primary dentin.

Andréa Soares de Oliveira Ortolan1, Carolina Paes Torres, Jaciara Miranda Gomes-Silva, Maria Angélica Hueb de Menezes-Oliveira, Jesus Djalma Pécora, Regina Guenka Palma-Dibb, Maria Cristina Borsatto.   

Abstract

OBJECTIVE: To evaluate the ablation capacity of different energies and pulse repetition rates of an erbium-doped yttrium aluminium garnet (Er:YAG) laser on primary dentin by assessing mass loss and to analyze the surface morphology using scanning electron microscopy (SEM). BACKGROUND DATA: Previous studies have demonstrated the ability of the Er:YAG laser to ablate dentin substrate.
METHODS: Forty-eight sound primary molars were bisected in the mesiodistal direction. The dentin surfaces were flattened, and initial mass (mg) was obtained. A 4-mm2 area was delimited. Specimens were randomly assigned to 12 groups according to the combination of energy (160, 200, 250, and 300 mJ) and pulse repetition rate (2, 3, and 4 Hz). Er:YAG laser irradiation was performed for 20 s. After irradiation, the final mass was obtained, and specimens were prepared for SEM. The data obtained by subtracting the final mass from the initial mass were statistically analyzed using analysis of variance and Tukey test (alpha=0.05).
RESULTS: The pulse repetition rate of 4 Hz provided greater mass loss, and it was different from 2 Hz and 3 HZ. The energy of 300 mJ resulted in greater mass loss, similar to 200 and 160 mJ. SEM micrographs showed dentinal tubule obliteration, structural alterations, and the presence of cracked areas in all specimens.
CONCLUSION: The settings of 160, 200, and 250 mJ at 2 and 3 Hz promoted a good ablation rate with fewer surface alterations in primary dentin.

Entities:  

Mesh:

Year:  2009        PMID: 20035602     DOI: 10.1089/pho.2008.2358

Source DB:  PubMed          Journal:  Photomed Laser Surg        ISSN: 1549-5418            Impact factor:   2.796


  5 in total

1.  Effect of Er:YAG laser application on the shear bond strength and microleakage between resin cements and Y-TZP ceramics.

Authors:  Hakan Akin; Faik Tugut; Gulsah Emine Akin; Umit Guney; Burcu Mutaf
Journal:  Lasers Med Sci       Date:  2011-01-21       Impact factor: 3.161

2.  Effect of Surface Treatment With Er:YAG and CO2 Lasers on Shear Bond Strength of Polyether Ether Ketone to Composite Resin Veneers.

Authors:  Yousef Jahandideh; Mehran Falahchai; Hossein Pourkhalili
Journal:  J Lasers Med Sci       Date:  2020-03-15

3.  Cavity Preparation by Laser in Primary Teeth: Effect of 2 Levels of Energy Output on the Shear Bond Strength of Composite Restoration to Dentin.

Authors:  Mehrsa Paryab; Shahrzad Sharifi; Mohammad Javad Kharazifard; Nazanin Kumarci
Journal:  J Lasers Med Sci       Date:  2018-07-06

4.  Minimally invasive treatment of dental caries in primary teeth using an Er:YAG Laser.

Authors:  Galia Zhegova; Maya Rashkova; Jean-Paul Rocca
Journal:  Laser Ther       Date:  2014-12-27

5.  Strength of the bond between a silicone lining material and denture resin after Er:YAG laser treatments with different pulse durations and levels of energy.

Authors:  Faik Tugut; Hakan Akin; Burcu Mutaf; Gulsah Emine Akin; Ali Kemal Ozdemir
Journal:  Lasers Med Sci       Date:  2010-12-14       Impact factor: 3.161