Literature DB >> 31749952

Cavity Preparation by Laser in Primary Teeth: Effect of 2 Levels of Energy Output on the Shear Bond Strength of Composite Restoration to Dentin.

Mehrsa Paryab1, Shahrzad Sharifi1, Mohammad Javad Kharazifard2, Nazanin Kumarci3.   

Abstract

Introduction: One of the main applications of laser in dentistry is the removal of dental caries and preparation of restorative cavities. The morphology and wettability of laser prepared surfaces are different from that of those prepared with conventional method which may affect the quality of the adhesive potential of bonding agents in these surfaces. This study aimed to assess the shear bond strength of a total-etch and self-etch adhesive system to primary tooth dentin prepared by two different energy densities of Er:YAG laser in comparison with surfaces prepared by bur.
Methods: A total of 60 human primary second molars extracted for orthodontic purposes were selected and randomly divided into 3 main groups of equal (n=20). Group A: Preparation of dentin surface by bur; group B: Preparation of dentin surface by laser with 300 mJ energy level; group C: Preparation of dentin surface by laser with 400 mJ energy level. In each of the main groups, the teeth were randomly assigned to 2 subgroups. Composite resin material was bonded with the total-etch adhesive system in subgroups A1, B1, and C1 and with the self-etch adhesive system in subgroups A2, B2, and C2. The samples were thermo-cycled, and composite restorations shear bond strength was measured in MPa. Data were analyzed using two-way analysis of variance (ANOVA), and P values less than 0.05 were considered statistically significant.
Results: The highest and the lowest shear bond strength values were observed in group A2 (Preparation by bur- Composite resin material bonded by Clearfil SE Bond) and group C2 (Preparation by laser with 400 mJ energy level - Composite resin material bonded by Clearfil SE Bond), respectively. The results showed no statistically significant differences between the study subgroups (P > 0.05).
Conclusion: It is concluded that in terms of shear bond strength to dentin, Single Bond and Clearfil SE Bond adhesive agents adequately perform in primary tooth dentin prepared by Er: YAG laser with energy levels of 300 and 400 mJ and frequency of 10 Hz.
Copyright © 2019 J Lasers Med Sci.

Entities:  

Keywords:  Bonding agent; Energy output; Er: YAG laser; Primary teeth; Shear bond strength; dentin

Year:  2018        PMID: 31749952      PMCID: PMC6817796          DOI: 10.15171/jlms.2019.38

Source DB:  PubMed          Journal:  J Lasers Med Sci        ISSN: 2008-9783


  38 in total

1.  The influence of three Erbium:YAG laser energies on the in vitro microleakage of Class V compomer resin restorations.

Authors:  E M Roebuck; C J Whitters; W P Saunders
Journal:  Int J Paediatr Dent       Date:  2001-01       Impact factor: 3.455

2.  Response of feline intradental nerve fibers to tooth cutting by Er:YAG laser.

Authors:  S Chaiyavej; H Yamamoto; A Takeda; H Suda
Journal:  Lasers Surg Med       Date:  2000       Impact factor: 4.025

Review 3.  Historical survey of laser dentistry.

Authors:  J G Sulewski
Journal:  Dent Clin North Am       Date:  2000-10

4.  Microtensile bond strength of contemporary adhesives to primary enamel and dentin.

Authors:  Marcela Marquezan; Bruno Lopes da Silveira; Luiz Henrique Burnett; Célia Regina Martins Delgado Rodrigues; Paulo Floriani Kramer
Journal:  J Clin Pediatr Dent       Date:  2008       Impact factor: 1.065

5.  Experimental studies of the application of the Er:YAG laser on dental hard substances: II. Light microscopic and SEM investigations.

Authors:  U Keller; R Hibst
Journal:  Lasers Surg Med       Date:  1989       Impact factor: 4.025

6.  Thermal alteration and morphological changes of sound and demineralized primary dentin after Er:YAG laser ablation.

Authors:  Cristina Bueno Brandão; Marta Maria Martins Giamatei Contente; Fabrício Augusto De Lima; Rodrigo Galo; Alessandra Marques Corrêa-Afonso; Luciano Bachmann; Maria Cristina Borsatto
Journal:  Microsc Res Tech       Date:  2011-07-14       Impact factor: 2.769

7.  Investigational study of the use of Er:YAG laser versus dental drill for caries removal and cavity preparation--phase I.

Authors:  J Pelagalli; C B Gimbel; R T Hansen; A Swett; D W Winn
Journal:  J Clin Laser Med Surg       Date:  1997

Review 8.  Evidence-based dentistry on laser paediatric dentistry: review and outlook.

Authors:  G Olivi; M D Genovese; C Caprioglio
Journal:  Eur J Paediatr Dent       Date:  2009-03       Impact factor: 2.231

9.  Bonding of adhesives to Er:YAG laser-treated dentin.

Authors:  Eugenia Koliniotou-Koumpia; Pantelis Kouros; Lazaros Zafiriadis; Effimia Koumpia; Pavlos Dionysopoulos; Vassilis Karagiannis
Journal:  Eur J Dent       Date:  2012-01

10.  Assessment of Tooth Preparation via Er:YAG Laser and Bur on Microleakage of Dentin Adhesives.

Authors:  Zahra Bahrololoomi; Elham Heydari
Journal:  J Dent (Tehran)       Date:  2014-03-31
View more
  1 in total

1.  Optical changes of human dentin after non-vital bleaching and effect of Er,Cr:YSGG laser on micro-shear bond strength of a self-etch and an etch-and-rinse adhesive system.

Authors:  İzgen Karakaya; Tağmaç Özberk
Journal:  Lasers Med Sci       Date:  2020-06-23       Impact factor: 3.161

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.