Literature DB >> 20035390

Interassay reproducibility of myocardial perfusion gated SPECT in patients with atrial fibrillation.

Santiago Aguadé-Bruix1, Guillermo Romero-Farina, Gemma Cuberas-Borros, Marta Milà-Lopez, Virginia Pubul-Núñez, Rosa Siurana-Escuer, David García-Dorado, Jaume Candell-Riera.   

Abstract

AIM: The aim of this study was to assess interassay reproducibility of myocardial perfusion gated-SPECT for calculation of end-diastolic volume (EDV), end-systolic volume (ESV), and left ventricular ejection fraction (LVEF) in patients with atrial fibrillation (AF).
METHODS: One hundred and fifteen consecutive patients with AF from three participating hospitals (mean age 68.9 years, 39 women) were included in the study. All patients underwent two image gated acquisitions at rest with a 30 minute interval between them. Quantitative data were obtained using the QGS and ECT software algorithms.
RESULTS: Heart rate was similar in both studies: 74.94 +/- 15.2 vs 73.03 +/- 15.57. QGS yielded an LVEF of 54.4%/53.8%, an EDV of 100 mL/101.5 mL, and an ESV of 51 mL/52.3 mL; and ECT showed an LVEF of 63.6%/62.9%, an EDV of 125.8 mL/127.4 mL and ESV of 54.1 mL/56.3 mL. Correlation between the two acquisitions was high (>0.948) for both methods for LVEF, EDV and ESV. Regression and Bland-Altman graphics showed a good agreement between all parameters. Interassay variation coefficients for each method (QGS/ECT) were 5.29% vs 4.83% for LVEF, 4.94% vs 5.17% for EDV, and 9.94% vs 12.78% for ESV.
CONCLUSIONS: Interassay reproducibility of LVEF and EDV with gated-SPECT in patients with AF is good, whereas for ESV it is suboptimal, particularly when ESV is small.

Entities:  

Mesh:

Year:  2009        PMID: 20035390     DOI: 10.1007/s12350-009-9186-6

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  18 in total

1.  Variability of serial same-day left ventricular ejection fraction using quantitative gated SPECT.

Authors:  Enrique Vallejo; Hugo Chaya; Gerardo Plancarte; Diana Victoria; David Bialostozky
Journal:  J Nucl Cardiol       Date:  2002 Jul-Aug       Impact factor: 5.952

2.  Assessment of systolic left ventricular function: a multi-centre comparison of cineventriculography, cardiac magnetic resonance imaging, unenhanced and contrast-enhanced echocardiography.

Authors:  Rainer Hoffmann; Stephan von Bardeleben; Folkert ten Cate; Adrian C Borges; Jaroslaw Kasprzak; Christian Firschke; Stephane Lafitte; Nidal Al-Saadi; Stefanie Kuntz-Hehner; Marc Engelhardt; Harald Becher; Jean Louis Vanoverschelde
Journal:  Eur Heart J       Date:  2004-12-17       Impact factor: 29.983

3.  A historical perspective on measurement of ventricular function with scintigraphic techniques: Part II--Ventricular function with gated techniques for blood pool and perfusion imaging.

Authors:  Kim A Williams
Journal:  J Nucl Cardiol       Date:  2005 Mar-Apr       Impact factor: 5.952

Review 4.  Optimal SPECT processing and display: making bad studies look good to get the right answer.

Authors:  Dalia Y Ibrahim; Frank P DiFilippo; Jeremy E Steed; Manuel D Cerqueira
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

Review 5.  Myocardial perfusion and function: single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Olakunle O Akinboboye; Daniel S Berman; Elias H Botvinick; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; Regina S Druz; Edward P Ficaro; James R Galt; Ravi K Garg; Guido Germano; Gary V Heller; Milena J Henzlova; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Robert A Quaife; Terrence D Ruddy; Senthil N Sundaram; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2007 Nov-Dec       Impact factor: 5.952

Review 6.  MRI of left ventricular function.

Authors:  Frederick H Epstein
Journal:  J Nucl Cardiol       Date:  2007 Sep-Oct       Impact factor: 5.952

7.  A scintiphotographic method for measuring left ventricular ejection fraction in man without cardiac catheterization.

Authors:  H W Strauss; B L Zaret; P J Hurley; T K Natarajan; B Pitt
Journal:  Am J Cardiol       Date:  1971-11       Impact factor: 2.778

8.  Temporal resolution requirements for left ventricular time-activity curves.

Authors:  A van Aswegen; P O Alderson; E L Nickoloff; D F Householder; H N Wagner
Journal:  Radiology       Date:  1980-04       Impact factor: 11.105

9.  Measurement of ventricular function by ECG gating during atrial fibrillation.

Authors:  S L Bacharach; M V Green; R O Bonow; S L Findley; H G Ostrow; G S Johnston
Journal:  J Nucl Med       Date:  1981-03       Impact factor: 10.057

10.  Variability of left ventricular ejection fraction and volumes with quantitative gated SPECT: influence of algorithm, pixel size and reconstruction parameters in small and normal-sized hearts.

Authors:  Anne-Sophie Hambye; Ann Vervaet; André Dobbeleir
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-07-31       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.