Literature DB >> 20035361

Retraction and fibroplasia in a polypropylene prosthesis: experimental study in rats.

L Zogbi1, A O V Portella, M R M Trindade, E N Trindade.   

Abstract

BACKGROUND: The treatment of hernia, independent of anatomical site and technique utilized, generally involves using prostheses, which may cause complications, despite their unarguable advantage in allowing safe reinforcement. An example of this is possible retraction, which causes discomfort and hernia recurrence. Polypropylene is still the most often used biomaterial of the great number available. The purpose of this study is to evaluate the amount of retraction of the polypropylene mesh, as well as the histological reactions that accompany this phenomenon.
METHODS: Polypropylene meshes (Marlex) were inserted in an anterior position to the whole abdominal aponeurosis of 25 Wistar rats (Rattus norvegicus albinus). The animals were divided into groups and another intervention was performed 7, 28, and 90 days later to measure the dimensions of the prostheses and to calculate the final area. Histological analysis was performed with hematoxylin-eosin to evaluate neutrophils, macrophages, giant cells, and lymphocytes surrounding the mesh threads in ten random fields of each slide.
RESULTS: Seven days after the mesh was inserted, the mean rate of retraction was 1.75% (P = 0.64); at 28 days, it was 3.75% (P = 0.02); and at 90 days, it was 2.5% (P = 0.01). As to the histological analysis, there was a total decline of neutrophils and a progressive increase of macrophages, giant cells, and lymphocytes proportional to the post-implant time of the mesh (P < 0.05).
CONCLUSION: There was a statistically significant retraction of 3.75% at 28 days and 2.5% at 90 days after the prosthesis was inserted. There is a well-established sequence of cellular events which aim at synthesizing new connective tissue to reinforce the mesh.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20035361     DOI: 10.1007/s10029-009-0607-x

Source DB:  PubMed          Journal:  Hernia        ISSN: 1248-9204            Impact factor:   4.739


  30 in total

1.  Tissue reactions to synthetic materials.

Authors:  J T SCALES
Journal:  Proc R Soc Med       Date:  1953-08

2.  Design of surgical meshes - an engineering perspective.

Authors:  Abhay S Pandit; Jerome A Henry
Journal:  Technol Health Care       Date:  2004       Impact factor: 1.285

Review 3.  Effect of lifestyle, gender and age on collagen formation and degradation.

Authors:  Lars Tue Sørensen
Journal:  Hernia       Date:  2006-12       Impact factor: 4.739

4.  The tension-free hernioplasty.

Authors:  I L Lichtenstein; A G Shulman; P K Amid; M M Montllor
Journal:  Am J Surg       Date:  1989-02       Impact factor: 2.565

5.  Trevira mesh: a promising new implant for the treatment of abdominal hernias.

Authors:  Jürgen Zieren; Folkert Maecker; Heiko Neuss; Jochen M Müller
Journal:  Langenbecks Arch Surg       Date:  2002-01-29       Impact factor: 3.445

6.  Functional and morphologic properties of a modified mesh for inguinal hernia repair.

Authors:  Karsten Junge; Uwe Klinge; Raphael Rosch; Bernd Klosterhalfen; Volker Schumpelick
Journal:  World J Surg       Date:  2002-09-26       Impact factor: 3.352

7.  A review of incisional hernia repairs: preoperative weight loss and selective use of the mesh repair.

Authors:  G Chan; C K Chan
Journal:  Hernia       Date:  2004-10-19       Impact factor: 4.739

8.  Tension-free hernia repair is associated with an increase in inflammatory response markers against the mesh.

Authors:  G Di Vita; S Milano; M Frazzetta; R Patti; V Palazzolo; C Barbera; V Ferlazzo; P Leo; E Cillari
Journal:  Am J Surg       Date:  2000-09       Impact factor: 2.565

9.  Collagen in the transversalis fascia of patients with indirect inguinal hernia: a case-control study.

Authors:  Antonio Britto Casanova; Eduardo Neubarth Trindade; Manoel Roberto Maciel Trindade
Journal:  Am J Surg       Date:  2008-12-18       Impact factor: 2.565

10.  Mesh implants in hernia repair. Inflammatory cell response in a rat model.

Authors:  R Rosch; K Junge; A Schachtrupp; U Klinge; B Klosterhalfen; V Schumpelick
Journal:  Eur Surg Res       Date:  2003 May-Jun       Impact factor: 1.745

View more
  5 in total

1.  Characterisation of the cellular infiltrate in the foreign body granuloma of textile meshes with its impact on collagen deposition.

Authors:  U Klinge; U Dietz; N Fet; B Klosterhalfen
Journal:  Hernia       Date:  2014-02-06       Impact factor: 4.739

Review 2.  Surgical perspectives regarding application of biomaterials for the management of large congenital diaphragmatic hernia defects.

Authors:  Amulya K Saxena
Journal:  Pediatr Surg Int       Date:  2018-04-02       Impact factor: 1.827

3.  Effect of alpha lipoic acid co-administration on structural and immunohistochemical changes in subcutaneous tissue of anterior abdominal wall of adult male albino rat in response to polypropylene mesh implantation.

Authors:  Shireen A Mazroa; Samar A Asker; Waleed Asker; Mohamed Abd Ellatif
Journal:  Int J Exp Pathol       Date:  2015-04-17       Impact factor: 1.925

4.  Comparative study of shrinkage, inflammatory response and fibroplasia in heavyweight and lightweight meshes.

Authors:  L Zogbi; E N Trindade; M R M Trindade
Journal:  Hernia       Date:  2013-01-24       Impact factor: 4.739

5.  PERITONEAL ADHESIONS TYPE I, III AND TOTAL COLLAGEN ON POLYPROPYLENE AND COATED POLYPROPYLENE MESHES: EXPERIMENTAL STUDY IN RATS.

Authors:  Lucas Félix Rossi; Manoel Roberto Maciel Trindade; Armando José D Acampora; Luise Meurer
Journal:  Arq Bras Cir Dig       Date:  2017 Apr-Jun
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.