Literature DB >> 20033496

Optimization of acquisition trajectories for 3D rotational coronary venography.

Jingying Bi1, Michael Grass, Dirk Schäfer.   

Abstract

OBJECTIVE: Rotational coronary X-ray imaging on C-arm systems provides a multitude of diagnostic projections from the vascular tree with a single contrast agent bolus. The acquisition trajectory is typically limited to a circular arc with a fixed caudo-cranial angulation. This may cause sub- optimal projection directions for specific vessel segments for all acquired views, e.g., those segments orthogonal to the axis of rotation. In this paper, a method is presented to calculate a patient-independent acquisition trajectory with respect to vessel foreshortening and overlap for multiple vessel segments of the coronary tree. This method can be applied to artery as well as vein anatomy.
METHODS: Rotational coronary venograms of 14 patients have been used to generate three-dimensional mesh representations with a semi-automatic two view modeling algorithm. The venous tree is divided into seven different vessel segments. Foreshortening and overlap of every segment are calculated and combined for all patients in a measure called obstruction value. The weighted obstruction values of all vessel segments define a cost function for the entire two-dimensional angular range of the C-arm system. Viterbi's algorithm is used to calculate an optimal trajectory with respect to this cost function. The method is validated by leave-one-out cross-validation on the 14 rotational venography data sets and on simulated venograms of a segmented computed tomography (CT) data set. Projection images with a foreshortening value below 10% and overlap below 20% are rated 'optimal'.
RESULTS: In 12 (85.7%) data sets, 43% more optimal images were acquired using the presented method compared to the standard circular arc trajectory. As well, in 13 (92.8%) data sets 38% more vessel segments can be optimally visualized in the acquired images. The test on the CT data set showed that the resulting average root-mean-square error of the extracted centerline points of the segmented CT data set compared to the error based on the views from the circular arc was reduced from 2.52 to 1.55 mm.
CONCLUSION: In a first test, the method proved to deliver improved image quality by reducing foreshortening and overlap of vessel segments and may therefore also improve the centerline extraction accuracy of the semi-automatic two view modeling method.

Entities:  

Mesh:

Year:  2009        PMID: 20033496     DOI: 10.1007/s11548-009-0398-7

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  23 in total

1.  Intra-procedural coronary intervention planning using hybrid 3-dimensional reconstruction techniques.

Authors:  Onno Wink; Richard Kemkers; Shiuh-Yung J Chen; John D Carroll
Journal:  Acad Radiol       Date:  2003-12       Impact factor: 3.173

2.  A quantitative analysis of 3-D coronary modeling from two or more projection images.

Authors:  B Movassaghi; V Rasche; M Grass; M A Viergever; W J Niessen
Journal:  IEEE Trans Med Imaging       Date:  2004-12       Impact factor: 10.048

3.  Left ventricular lead performance in cardiac resynchronization therapy: impact of lead localization and complications.

Authors:  Andi Eie Albertsen; Jens Cosedis Nielsen; Anders Kirstein Pedersen; Peter Steen Hansen; Henrik Kjaerulf Jensen; Peter Thomas Mortensen
Journal:  Pacing Clin Electrophysiol       Date:  2005-06       Impact factor: 1.976

4.  Rotational angiography (RA) and three-dimensional imaging (3-DRA): an available clinical tool.

Authors:  Joel A Garcia; James Chen; Adam Hansgen; Onno Wink; Babak Movassaghi; John C Messenger
Journal:  Int J Cardiovasc Imaging       Date:  2006-06-16       Impact factor: 2.357

5.  Three-dimensional X-ray coronary angiography in the porcine model: A feasibility study.

Authors:  Volker Rasche; Babak Movassaghi; Michael Grass; Dirk Schäfer; Harald P Kühl; Rolf W Günther; Arno Bücker
Journal:  Acad Radiol       Date:  2006-05       Impact factor: 3.173

6.  Reconstruction of coronary arteries from a single rotational X-ray projection sequence.

Authors:  Christophe Blondel; Grégoire Malandain; Régis Vaillant; Nicholas Ayache
Journal:  IEEE Trans Med Imaging       Date:  2006-05       Impact factor: 10.048

7.  Determination of optimal angiographic viewing angles: basic principles and evaluation study.

Authors:  A M Dumay; J C Reiber; J J Gerbrands
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

8.  3D coronary reconstruction from routine single-plane coronary angiograms: clinical validation and quantitative analysis of the right coronary artery in 100 patients.

Authors:  J C Messenger; S Y Chen; J D Carroll; J E Burchenal; K Kioussopoulos; B M Groves
Journal:  Int J Card Imaging       Date:  2000-12

9.  Angiographic views used for percutaneous coronary interventions: a three-dimensional analysis of physician-determined vs. computer-generated views.

Authors:  Nathan E Green; S-Y James Chen; Adam R Hansgen; John C Messenger; Bertron M Groves; John D Carroll
Journal:  Catheter Cardiovasc Interv       Date:  2005-04       Impact factor: 2.692

10.  High-resolution selective three-dimensional magnetic resonance coronary angiography with navigator-echo technique: segment-by-segment evaluation of coronary artery stenosis.

Authors:  Yuji Watanabe; Masako Nagayama; Yoshiki Amoh; Masako Fujii; Yasushi Fuku; Akira Okumura; Marc Van Cauteren; Matthias Stuber; Yoshihiro Dodo
Journal:  J Magn Reson Imaging       Date:  2002-09       Impact factor: 4.813

View more
  1 in total

1.  Measurement of peripheral arterial vasculature in domestic Yorkshire swine by using quantitative vascular angiography.

Authors:  Vanessa C Lopes-Berkas; Michael A Jorgenson
Journal:  J Am Assoc Lab Anim Sci       Date:  2011-09       Impact factor: 1.232

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.