Literature DB >> 20031425

An automated ionization chamber for secondary radioactivity standards.

R Fitzgerald1.   

Abstract

I report on the operation and characterization of a new ionization chamber system, "AUTOIC", featuring a commercial digital electrometer and a commercial robotic sample changer. The relative accuracy of the electrometer was improved significantly beyond the manufacturer's specifications through an in-house calibration of the various ranges, applied via software. The measurement precision and repeatability of the system have been determined by measuring multiple samples of the same radionuclide over the span of two or three years. The linearity of the system was examined by following the decay of (99m)Tc, (99)Mo and (133)Xe sources for up to 19 half-lives and determining half-life values. All of these values agree with the accepted literature values, within their combined uncertainties. Published by Elsevier Ltd.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20031425     DOI: 10.1016/j.apradiso.2009.12.008

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  8 in total

1.  Standardization of I-124 by three liquid scintillation-based methods.

Authors:  D E Bergeron; J T Cessna; R Fitzgerald; L Pibida; B E Zimmerman
Journal:  Appl Radiat Isot       Date:  2019-08-09       Impact factor: 1.513

2.  Determination of photon emission probability for the main gamma ray and half-life measurements of 64Cu.

Authors:  L Pibida; B Zimmerman; D E Bergeron; R Fitzgerald; J T Cessna; L King
Journal:  Appl Radiat Isot       Date:  2017-07-04       Impact factor: 1.513

3.  Radionuclide calibrator responses for 224Ra in solution and adsorbed on calcium carbonate microparticles.

Authors:  Elisa Napoli; Jeffrey T Cessna; Leticia Pibida; Ryan Fitzgerald; Gro E Hjellum; Denis E Bergeron
Journal:  Appl Radiat Isot       Date:  2020-06-12       Impact factor: 1.513

4.  Two determinations of the Ge-68 half-life.

Authors:  Denis E Bergeron; Jeffrey T Cessna; Brian E Zimmerman
Journal:  Appl Radiat Isot       Date:  2017-10-20       Impact factor: 1.513

5.  Primary standardization of 224Ra activity by liquid scintillation counting.

Authors:  Elisa Napoli; Jeffrey T Cessna; Ryan Fitzgerald; Leticia Pibida; Ronald Collé; Lizbeth Laureano-Pérez; Brian E Zimmerman; Denis E Bergeron
Journal:  Appl Radiat Isot       Date:  2019-10-11       Impact factor: 1.513

6.  Ra-224 activity, half-life, and 241 keV gamma ray absolute emission intensity: A NIST-NPL bilateral comparison.

Authors:  Denis E Bergeron; Sean M Collins; Leticia Pibida; Jeffrey T Cessna; Ryan Fitzgerald; Brian E Zimmerman; Peter Ivanov; John D Keightley; Elisa Napoli
Journal:  Appl Radiat Isot       Date:  2020-12-31       Impact factor: 1.513

7.  A Review of NIST Primary Activity Standards for (18)F: 1982 to 2013.

Authors:  Denis E Bergeron; Jeffrey T Cessna; Bert M Coursey; Ryan Fitzgerald; Brian E Zimmerman
Journal:  J Res Natl Inst Stand Technol       Date:  2014-08-27

8.  Revision of the NIST Standard for (223)Ra: New Measurements and Review of 2008 Data.

Authors:  B E Zimmerman; D E Bergeron; J T Cessna; R Fitzgerald; L Pibida
Journal:  J Res Natl Inst Stand Technol       Date:  2015-03-11
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.