Direct comparison of sensitivity encoding (SENSE) accelerated and conventional 3D contrast enhanced magnetic resonance angiography (CE-MRA) of renal arteries: effect of increasing spatial resolution.

R Muthupillai1, E Douglas, S Huber, B Lambert, M Pereyra, G J Wilson, S D Flamm.   

Abstract

PURPOSE: To assess the effect of attaining higher spatial resolution in contrast-enhanced magnetic resonance angiography (MRA) of renal arteries using parallel imaging, sensitivity encoding (SENSE), by comparing the SENSE contrast-enhanced (CE) MRA against a conventional CE-MRA protocol with identical scan times, injection protocol, and other acquisition parameters.
MATERIALS AND METHODS: Numerical simulations and a direct comparison of SENSE-accelerated versus conventional acquisitions were performed. A total of 41 patients (18 male) were imaged using both protocols for a direct comparison. Both protocols used fluoroscopic triggering, centric encoding, breath-holding, equivalent injection protocol, and lasted approximately 30 seconds.
RESULTS: Simulated point-spread functions were narrower for the SENSE protocol compared to the conventional protocol. In the patient study, although the SENSE protocol produced images with lower signal-to-noise ratio (SNR), image quality was better for all segments of the renal arteries. In addition, ringing of kidney parenchyma and renal artery blurring were significantly reduced in the SENSE protocol. Finally, reader confidence improved with the SENSE protocol.
CONCLUSION: Despite a reduction in SNR, the higher-resolution SENSE CE-MRA provided improved image quality, reduced artifacts, and increased reader confidence compared to the conventional protocol. (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20027583     DOI: 10.1002/jmri.22002

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  7 in total

1.  Recent advances in 3D time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch; Paul T Weavers; Phillip M Young
Journal:  J Magn Reson Imaging       Date:  2015-06-01       Impact factor: 4.813

2.  Prospective comparison of late 3T MRI with conventional angiography in evaluating the patency of cerebral arteriovenous malformations treated with stereotactic radiosurgery.

Authors:  Nader Khandanpour; Paul Griffiths; Daniel Warren; Nigel Hoggard
Journal:  Neuroradiology       Date:  2013-02-26       Impact factor: 2.804

Review 3.  Recent advances in parallel imaging for MRI.

Authors:  Jesse Hamilton; Dominique Franson; Nicole Seiberlich
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2017-05-02       Impact factor: 9.795

4.  Assessment of the kidneys: magnetic resonance angiography, perfusion and diffusion.

Authors:  Ulrike I Attenberger; John N Morelli; Stefan O Schoenberg; Henrik J Michaely
Journal:  J Cardiovasc Magn Reson       Date:  2011-11-15       Impact factor: 5.364

5.  Contrast-enhanced MR angiography of the abdomen with highly accelerated acquisition techniques.

Authors:  Petrice M Mostardi; James F Glockner; Phillip M Young; Stephen J Riederer
Journal:  Radiology       Date:  2011-09-07       Impact factor: 11.105

Review 6.  Parallel MR imaging.

Authors:  Anagha Deshmane; Vikas Gulani; Mark A Griswold; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2012-07       Impact factor: 4.813

7.  Vascular masking for improved unfolding in 2D SENSE-accelerated 3D contrast-enhanced MR angiography.

Authors:  Eric G Stinson; Eric A Borisch; Casey P Johnson; Joshua D Trzasko; Phillip M Young; Stephen J Riederer
Journal:  J Magn Reson Imaging       Date:  2013-07-29       Impact factor: 4.813