Literature DB >> 20020414

Fully automated liquid extraction-based surface sampling and ionization using a chip-based robotic nanoelectrospray platform.

Vilmos Kertesz1, Gary J Van Berkel.   

Abstract

A fully automated liquid extraction-based surface sampling device utilizing an Advion NanoMate chip-based infusion nanoelectrospray ionization system is reported. Analyses were enabled for discrete spot sampling by using the Advanced User Interface of the current commercial control software. This software interface provided the parameter control necessary for the NanoMate robotic pipettor to both form and withdraw a liquid microjunction for sampling from a surface. The system was tested with three types of analytically important sample surface types, viz., spotted sample arrays on a MALDI plate, dried blood spots on paper, and whole-body thin tissue sections from drug dosed mice. The qualitative and quantitative data were consistent with previous studies employing other liquid extraction-based surface sampling techniques. Published in 2009 by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2010        PMID: 20020414     DOI: 10.1002/jms.1709

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  62 in total

1.  N-Glycan profiling of dried blood spots.

Authors:  L Renee Ruhaak; Suzanne Miyamoto; Karen Kelly; Carlito B Lebrilla
Journal:  Anal Chem       Date:  2011-12-19       Impact factor: 6.986

2.  Liquid microjunction surface sampling probe fluid dynamics: characterization and application of an analyte plug formation operational mode.

Authors:  Mariam S ElNaggar; Gary J Van Berkel
Journal:  J Am Soc Mass Spectrom       Date:  2011-08-10       Impact factor: 3.109

3.  Ambient Molecular Analysis of Biological Tissue Using Low-Energy, Femtosecond Laser Vaporization and Nanospray Postionization Mass Spectrometry.

Authors:  Fengjian Shi; Paul M Flanigan; Jieutonne J Archer; Robert J Levis
Journal:  J Am Soc Mass Spectrom       Date:  2015-12-14       Impact factor: 3.109

4.  Imaging mass spectrometry for natural products discovery: a review of ionization methods.

Authors:  Joseph E Spraker; Gordon T Luu; Laura M Sanchez
Journal:  Nat Prod Rep       Date:  2020-02-26       Impact factor: 13.423

5.  High Resolution Tissue Imaging Using the Single-probe Mass Spectrometry under Ambient Conditions.

Authors:  Wei Rao; Ning Pan; Zhibo Yang
Journal:  J Am Soc Mass Spectrom       Date:  2015-03-25       Impact factor: 3.109

6.  Analysis of Urine, Oral fluid and Fingerprints by Liquid Extraction Surface Analysis Coupled to High Resolution MS and MS/MS - Opportunities for Forensic and Biomedical Science.

Authors:  Melanie Bailey; Elizabeth C Randall; Catia Costa; Tara L Salter; Alan M Race; Marcel de Puit; Mattijs Koeberg; Mark Baumert; Josephine Bunch
Journal:  Anal Methods       Date:  2016-03-24       Impact factor: 2.896

7.  Ambient ionization and miniature mass spectrometry system for chemical and biological analysis.

Authors:  Xiaoxiao Ma; Zheng Ouyang
Journal:  Trends Analyt Chem       Date:  2016-12       Impact factor: 12.296

8.  High-Resolution Ambient MS Imaging of Negative Ions in Positive Ion Mode: Using Dicationic Reagents with the Single-Probe.

Authors:  Wei Rao; Ning Pan; Xiang Tian; Zhibo Yang
Journal:  J Am Soc Mass Spectrom       Date:  2016-01       Impact factor: 3.109

9.  Towards High-Resolution Tissue Imaging Using Nanospray Desorption Electrospray Ionization Mass Spectrometry Coupled to Shear Force Microscopy.

Authors:  Son N Nguyen; Ryan L Sontag; James P Carson; Richard A Corley; Charles Ansong; Julia Laskin
Journal:  J Am Soc Mass Spectrom       Date:  2017-07-28       Impact factor: 3.109

10.  An Integrated Microfluidic Probe for Mass Spectrometry Imaging of Biological Samples*.

Authors:  Xiangtang Li; Ruichuan Yin; Hang Hu; Yingju Li; Xiaofei Sun; Sudhansu K Dey; Julia Laskin
Journal:  Angew Chem Int Ed Engl       Date:  2020-10-09       Impact factor: 15.336

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.