Literature DB >> 20012937

Mechanized pivot shift test achieves greater accuracy than manual pivot shift test.

Volker Musahl1, James Voos, Padhraig F O'Loughlin, Volker Stueber, Daniel Kendoff, Andrew D Pearle.   

Abstract

The objective of this study was to design a navigated mechanized pivot shift test setup and evaluate its repeatability in the ACL-deficient knee. It was hypothesized that translations and rotations measured with the mechanized pivot shift would be more repeatable when compared to those obtained with a manual pivot shift. Twelve fresh frozen cadaveric hip-to-toe whole lower extremities were used for this study. A manual pivot shift test was performed in the intact knee and in the ACL-deficient knee and was repeated three times. A navigation system simultaneously recorded tibial translation and rotation. The mechanized pivot shift test consists of a modified continuous passive motion (CPM) machine and a custom-made foot holder to allow for the application of internal rotation moments at the knee. Valgus moments were achieved by a 45 degrees tilt of the CPM machine with respect to the supine position and a Velcro strap secured across the proximal tibia. The mechanized pivot shift was repeated three times. Repeated measures ANOVA was used to compare manual and mechanized pivot shift testing. An intra-class correlation coefficient (ICC) was used to determine variability within each knee at each testing condition. In the ACL-deficient knee, translation with manual pivot shift testing (11.7 +/- 2.6 mm) was significantly higher than with mechanized pivot shift testing (7.4 +/- 2.5 mm; p < 0.05). Rotation with the manual pivot shift testing (18.6 +/- 5.4 degrees) was also significantly higher than with mechanized pivot shift testing (11.0 +/- 2.3 degrees; p < 0.05). The intra-class ICC for translations was 0.76 for manual pivot shift and 0.92 for the mechanized pivot shift test. The intra-class ICC for rotations was 0.89 for manual pivot shift and 0.82 for the mechanized pivot shift test. This study introduced a modified CPM for mechanized pivot shift testing. Although recorded translations and rotations with the mechanized pivot shift test were lower than with manual testing, the clinical advantage of mechanized pivot shift testing is a more repeatable measurement of ATT when compared to manual pivot shift testing. This setup may increase consistency of clinical grading of the pivot shift test.

Entities:  

Mesh:

Year:  2009        PMID: 20012937     DOI: 10.1007/s00167-009-1004-9

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  19 in total

1.  Reliability of navigated knee stability examination: a cadaveric evaluation.

Authors:  Andrew D Pearle; Daniel J Solomon; Tony Wanich; Alexandre Moreau-Gaudry; Carinne C Granchi; Thomas L Wickiewicz; Russell F Warren
Journal:  Am J Sports Med       Date:  2007-04-17       Impact factor: 6.202

2.  Computer evaluation of kinematics of anterior cruciate ligament reconstructions.

Authors:  Hanno Steckel; Patricia E Murtha; Ryan S Costic; James E Moody; Branislav Jaramaz; Freddie H Fu
Journal:  Clin Orthop Relat Res       Date:  2007-10       Impact factor: 4.176

3.  In vivo analysis of the pivot shift phenomenon during computer navigated ACL reconstruction.

Authors:  Clayton G Lane; Russell F Warren; Fatima C Stanford; Daniel Kendoff; Andrew D Pearle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-05       Impact factor: 4.342

4.  Use of the International Knee Documentation Committee guidelines to assess outcome following anterior cruciate ligament reconstruction.

Authors:  J J Irrgang; H Ho; C D Harner; F H Fu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  1998       Impact factor: 4.342

5.  The diagnostic accuracy of ruptures of the anterior cruciate ligament comparing the Lachman test, the anterior drawer sign, and the pivot shift test in acute and chronic knee injuries.

Authors:  J W Katz; R J Fingeroth
Journal:  Am J Sports Med       Date:  1986 Jan-Feb       Impact factor: 6.202

6.  Evaluation of an external device measuring knee joint rotation: an in vivo study with simultaneous Roentgen stereometric analysis.

Authors:  Per O Almquist; Arnbjörn Arnbjörnsson; Rose Zätterström; Leif Ryd; Charlotte Ekdahl; Thomas Fridén
Journal:  J Orthop Res       Date:  2002-05       Impact factor: 3.494

7.  Simulated pivot-shift testing with single and double-bundle anterior cruciate ligament reconstructions.

Authors:  Keith L Markolf; Samuel Park; Steven R Jackson; David R McAllister
Journal:  J Bone Joint Surg Am       Date:  2008-08       Impact factor: 5.284

8.  Intraoperative measurement of knee kinematics in reconstruction of the anterior cruciate ligament.

Authors:  A M J Bull; P H Earnshaw; A Smith; M V Katchburian; A N A Hassan; A A Amis
Journal:  J Bone Joint Surg Br       Date:  2002-09

9.  The pivot shift phenomenon: results and description of a modified clinical test for anterior cruciate ligament insufficiency.

Authors:  B R Bach; R F Warren; T L Wickiewicz
Journal:  Am J Sports Med       Date:  1988 Nov-Dec       Impact factor: 6.202

10.  Double-bundle ACL reconstruction: influence of femoral tunnel orientation in knee laxity analysed with a navigation system - an in-vitro biomechanical study.

Authors:  Stefano Zaffagnini; Danilo Bruni; Sandra Martelli; Naoaki Imakiire; Maurilio Marcacci; Alessandro Russo
Journal:  BMC Musculoskelet Disord       Date:  2008-02-25       Impact factor: 2.362

View more
  42 in total

1.  Clinical grading of the pivot shift test correlates best with tibial acceleration.

Authors:  Mattias Ahldén; Paulo Araujo; Yuichi Hoshino; Kristian Samuelsson; Kellie K Middleton; Kouki Nagamune; Jón Karlsson; Volker Musahl
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-04       Impact factor: 4.342

Review 2.  Dynamic knee laxity measurement devices.

Authors:  Mattias Ahldén; Yuichi Hoshino; Kristian Samuelsson; Paulo Araujo; Volker Musahl; Jón Karlsson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-12-31       Impact factor: 4.342

3.  Effect of tibial slope on the stability of the anterior cruciate ligament-deficient knee.

Authors:  James E Voos; Eduardo M Suero; Musa Citak; Frank P Petrigliano; Marianne R F Bosscher; Mustafa Citak; Thomas L Wickiewicz; Andrew D Pearle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-12-20       Impact factor: 4.342

Review 4.  What does it take to have a high-grade pivot shift?

Authors:  M Tanaka; D Vyas; G Moloney; A Bedi; A D Pearle; V Musahl
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-06       Impact factor: 4.342

5.  Anteromedial versus central single-bundle graft position: which anatomic graft position to choose?

Authors:  Michael B Cross; Volker Musahl; Asheesh Bedi; Padhraig O'Loughlin; Sommer Hammoud; Eduardo Suero; Andrew D Pearle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-05       Impact factor: 4.342

Review 6.  Can the pivot-shift be eliminated by anatomic double-bundle anterior cruciate ligament reconstruction?

Authors:  Stefano Zaffagnini; Giulio Maria Marcheggiani Muccioli; Nicola Lopomo; Cecilia Signorelli; Tommaso Bonanzinga; Costanza Musiani; Papakonstantinou Vassilis; Marco Nitri; Maurilio Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-24       Impact factor: 4.342

7.  Comparison of tunnel positions in single-bundle anterior cruciate ligament reconstructions using computer navigation.

Authors:  James E Voos; Volker Musahl; Travis G Maak; Thomas L Wickiewicz; Andrew D Pearle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-05-18       Impact factor: 4.342

8.  Lateral compartment translation predicts the grade of pivot shift: a cadaveric and clinical analysis.

Authors:  Asheesh Bedi; Volker Musahl; Clayton Lane; Musa Citak; Russell F Warren; Andrew D Pearle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-05-18       Impact factor: 4.342

9.  A mechanized and standardized pivot shifter: technical description and first evaluation.

Authors:  Musa Citak; Eduardo M Suero; Joshua C Rozell; Marianne Roberta Frederiek Bosscher; Julian Kuestermeyer; Andrew D Pearle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-10-15       Impact factor: 4.342

10.  A mechanical pivot-shift device for continuously applying defined loads to cadaveric knees.

Authors:  Mark P Sena; Ryan DellaMaggioria; Jeffrey C Lotz; Brian T Feeley
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-09-10       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.