INTRODUCTION: Eddy currents induced by switching of magnetic field gradients can lead to distortions in short echo-time spectroscopy or diffusion weighted imaging. In small bore magnets, such as human head-only systems, minimization of eddy current effects is more demanding because of the proximity of the gradient coil to conducting structures. METHODS: In the present study, the eddy current behavior achievable on a recently installed 7 tesla-68 cm bore head-only magnet was characterized. RESULTS: Residual effects after compensation were shown to be on the same order of magnitude as those measured on two whole body systems (3 and 4.7 T), while using two to three fold increased gradient slewrates.
INTRODUCTION: Eddy currents induced by switching of magnetic field gradients can lead to distortions in short echo-time spectroscopy or diffusion weighted imaging. In small bore magnets, such as human head-only systems, minimization of eddy current effects is more demanding because of the proximity of the gradient coil to conducting structures. METHODS: In the present study, the eddy current behavior achievable on a recently installed 7 tesla-68 cm bore head-only magnet was characterized. RESULTS: Residual effects after compensation were shown to be on the same order of magnitude as those measured on two whole body systems (3 and 4.7 T), while using two to three fold increased gradient slewrates.
Authors: William M Spees; Niels Buhl; Peng Sun; Joseph J H Ackerman; Jeffrey J Neil; Joel R Garbow Journal: J Magn Reson Date: 2011-06-25 Impact factor: 2.229
Authors: Thomas K F Foo; Evangelos Laskaris; Mark Vermilyea; Minfeng Xu; Paul Thompson; Gene Conte; Christopher Van Epps; Christopher Immer; Seung-Kyun Lee; Ek T Tan; Dominic Graziani; Jean-Baptise Mathieu; Christopher J Hardy; John F Schenck; Eric Fiveland; Wolfgang Stautner; Justin Ricci; Joseph Piel; Keith Park; Yihe Hua; Ye Bai; Alex Kagan; David Stanley; Paul T Weavers; Erin Gray; Yunhong Shu; Matthew A Frick; Norbert G Campeau; Joshua Trzasko; John Huston; Matt A Bernstein Journal: Magn Reson Med Date: 2018-03-13 Impact factor: 4.668
Authors: Shengzhen Tao; Paul T Weavers; Joshua D Trzasko; Yunhong Shu; John Huston; Seung-Kyun Lee; Louis M Frigo; Matt A Bernstein Journal: Magn Reson Med Date: 2016-07-04 Impact factor: 4.668
Authors: Birgit R Plantinga; Yasin Temel; Alard Roebroeck; Kâmil Uludağ; Dimo Ivanov; Mark L Kuijf; Bart M Ter Haar Romenij Journal: Front Hum Neurosci Date: 2014-11-05 Impact factor: 3.169