Literature DB >> 20010308

Predictable healing of femoral neck fractures treated with intraoperative compression and length-stable implants.

Sreevathsa Boraiah1, Omesh Paul, Sommer Hammoud, Michael J Gardner, David L Helfet, Dean G Lorich.   

Abstract

OBJECTIVES: A healed, yet shortened, femoral neck has historically been deemed a success in fracture treatment. This, however, comes at the price of diminished physical function and quality of life. We analyzed the outcomes of our treatment algorithm, which attempts to minimize postoperative shortening of femoral neck fractures and determined which preoperative factors were associated with femoral neck shortening and failure of surgical fixation. LEVEL OF EVIDENCE: This is level IV retrospective study. MATERIALS: Fifty-four patients underwent open reduction and internal fixation for acute femoral neck fracture with nonsliding constructs. The collapse of the femoral neck in the horizontal (X), vertical (Y), and along the resultant along the (Z) vector (X+Y=Z) was measured on anteroposterior radiographs corrected for leg rotation. The migration of the superior-most screw tip in all axes was measured. Age, gender, Garden grade, and Pauwel's angle were analyzed for their association with shortening or failure of surgical fixation.
RESULTS: The average age of the patients was 78.1 years. There were 23 Garden I, 2 Garden II, 14 Garden III, and 15 Garden IV fractures. Fifty-one (94%) healed successfully without complications. The minimum follow-up was 9 months (average, 17.6 months; range, 9-30 months). Surgical fixation failed in two patients, and one patient developed avascular necrosis. The average displacement of the femoral head and the screw tip was 1.23, 0.86, 1.98 mm and 0.7 mm, 0.9 mm, and 1.7 mm in the X, Y, and Z (resultant) vectors, respectively. DISCUSSION: With careful consideration to reduction, we fixed femoral neck fractures with nonsliding constructs, resulting in a high union rate with very minimal shortening of the femoral neck.

Entities:  

Mesh:

Year:  2010        PMID: 20010308     DOI: 10.1097/TA.0b013e3181bba236

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  11 in total

1.  [Short- and medium-term effectiveness of percutaneous compression plate internal fixation in the treatment of femoral neck fractures in the elderly].

Authors:  Huanxiang Bao; Haifeng Li; Sanjun Gu; Weiya Zhang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-08-15

2.  Factors Associated with Femoral Neck Shortening After Closed or Open Reduction and Screw Fixation.

Authors:  Abdulkadir Polat; Abdulhamit Misir; Mehmet Ozbey Buyukkuscu; Seckin Basilgan; Hakan Basar
Journal:  Indian J Orthop       Date:  2021-08-14       Impact factor: 1.033

3.  Presence of a nail in the medullary canal; is it enough to prevent femoral neck shortening in trochanteric fracture?

Authors:  Hyung Keun Song; Han Kuk Yoon; Kyu Hyun Yang
Journal:  Yonsei Med J       Date:  2014-09       Impact factor: 2.759

4.  Risk Factors for Neck Shortening in Patients with Valgus Impacted Femoral Neck Fractures Treated with Three Parallel Screws: Is Bone Density an Affecting Factor?

Authors:  Yerl-Bo Sung; Eui-Yub Jung; Kyung-Il Kim; Soo-Yeon Kim
Journal:  Hip Pelvis       Date:  2017-12-01

5.  Dynamic hip system blade versus cannulated compression screw for the treatment of femoral neck fractures: A retrospective study.

Authors:  Chao Chen; Li Yu; Xin Tang; Mo-Zhen Liu; Li-Zhong Sun; Changjian Liu; Zhen Zhang; Chang-Zhou Li
Journal:  Acta Orthop Traumatol Turc       Date:  2017-08-26       Impact factor: 1.511

6.  Intramedullary nails with cannulated screw fixation for the treatment of unstable femoral neck fractures.

Authors:  Jialiang Guo; Weichong Dong; Bing Yin; Lin Jin; Zhe Lin; Zhiyong Hou; Yingze Zhang
Journal:  J Int Med Res       Date:  2018-12-11       Impact factor: 1.671

7.  Treatment of basicervical femoral neck fractures with proximal femoral nail antirotation.

Authors:  Jialiang Guo; Weichong Dong; Lin Jin; Yingchao Yin; Ruipeng Zhang; Zhiyong Hou; Yingze Zhang
Journal:  J Int Med Res       Date:  2019-07-21       Impact factor: 1.671

8.  Decreased complications but a distinctive fixation loosening mechanism of fully threaded headless cannulated screw fixation for femoral neck fractures in young adults.

Authors:  Hui Sun; Lin-Yuan Shu; Matthew C Sherrier; Yi Zhu; Jing-Wen Liu; Wei Zhang
Journal:  J Orthop Surg Res       Date:  2021-03-30       Impact factor: 2.359

9.  Modified valgus osteotomy of the femoral neck for late presenting femoral neck stress fractures in military recruitsw.

Authors:  Satya Prakash Singh; Yashwant Tanwar; Atin Jaiswal; Masood Habib
Journal:  Indian J Orthop       Date:  2014-05       Impact factor: 1.251

Review 10.  Biomechanics of Osteoporotic Fracture Fixation.

Authors:  Marianne Hollensteiner; Sabrina Sandriesser; Emily Bliven; Christian von Rüden; Peter Augat
Journal:  Curr Osteoporos Rep       Date:  2019-12       Impact factor: 5.096

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.