Literature DB >> 20007394

Comparison of the Abbott RealTime CT new formulation assay with two other commercial assays for detection of wild-type and new variant strains of Chlamydia trachomatis.

Jens Kjølseth Møller1, Lisbeth Nørum Pedersen, Kenneth Persson.   

Abstract

In an analytical-method comparison study of clinical samples, the Abbott RealTime CT new formulation assay (m2000 real-time PCR), consisting of a duplex PCR targeting different parts of the cryptic plasmid in Chlamydia trachomatis, was compared both with version 2 of the Roche Cobas TaqMan CT assay, comprising a duplex PCR for a target in the cryptic plasmid and the omp1 gene, and with the Gen-Probe Aptima Combo 2 assay (AC2) targeting the C. trachomatis 23S rRNA molecule. First-catch urine samples from Sweden were tested in Malmö, Sweden, for C. trachomatis with the m2000 real-time PCR assay and with an in-house PCR for the new variant C. trachomatis strain with a deletion in the cryptic plasmid. Aliquots of the urine samples were sent to Aarhus, Denmark, where they were further examined with the TaqMan CT and AC2 assays. A positive prevalence of 9.1% (148/1,632 urine samples examined) was detected according to the combined reference standard. The sensitivities and specificities of the three assays were as follows: for the Abbott m2000 assay, 95.3% (141/148) and 99.9% (1,483/1,485), respectively; for the Roche TaqMan assay, 82.4% (122/148) and 100.0% (1,485/1,485); and for the Gen-Probe AC2 assay, 99.3% (147/148) and 99.9% (1,484/1,485). The plasmid mutant strain was detected in 24% (36/148) of the C. trachomatis-positive samples. There is a difference in sensitivity between the new formulations of the Abbott and the Roche assays, but both assays detected the wild-type and new variant C. trachomatis strains equally well.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20007394      PMCID: PMC2815632          DOI: 10.1128/JCM.01446-09

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  6 in total

1.  A variant of Chlamydia trachomatis with deletion in cryptic plasmid: implications for use of PCR diagnostic tests.

Authors:  T Ripa; P Nilsson
Journal:  Euro Surveill       Date:  2006-11-09

2.  Impact of a genetic variant of Chlamydia trachomatis on national detection rates in Sweden.

Authors:  T Soderblom; A Blaxhult; H Fredlund; B Herrmann
Journal:  Euro Surveill       Date:  2006-12-07

3.  A Chlamydia trachomatis strain with a 377-bp deletion in the cryptic plasmid causing false-negative nucleic acid amplification tests.

Authors:  Torvald Ripa; Peter A Nilsson
Journal:  Sex Transm Dis       Date:  2007-05       Impact factor: 2.830

4.  Evaluation of the new COBAS TaqMan CT test v2.0 and impact on the proportion of new variant Chlamydia trachomatis by the introduction of diagnostics detecting new variant C trachomatis in Orebro county, Sweden.

Authors:  R Hadad; H Fredlund; M Unemo
Journal:  Sex Transm Infect       Date:  2008-12-05       Impact factor: 3.519

5.  Comparison of Gen-probe transcription-mediated amplification, Abbott PCR, and Roche PCR assays for detection of wild-type and mutant plasmid strains of Chlamydia trachomatis in Sweden.

Authors:  Jens Kjølseth Møller; Lisbeth Nørum Pedersen; Kenneth Persson
Journal:  J Clin Microbiol       Date:  2008-10-08       Impact factor: 5.948

6.  Evaluation of the Abbott RealTime CT assay with the BD ProbeTec ET assay for the detection of Chlamydia trachomatis in a clinical microbiology laboratory.

Authors:  Anne Walsh; Fiona O Rourke; Bairbre Ní Laoi; Brendan Crowley
Journal:  Diagn Microbiol Infect Dis       Date:  2009-05       Impact factor: 2.803

  6 in total
  17 in total

1.  Analytical evaluation of GeneXpert CT/NG, the first genetic point-of-care assay for simultaneous detection of Neisseria gonorrhoeae and Chlamydia trachomatis.

Authors:  Sepehr N Tabrizi; Magnus Unemo; Daniel Golparian; Jimmy Twin; Athena E Limnios; Monica Lahra; Rebecca Guy
Journal:  J Clin Microbiol       Date:  2013-04-03       Impact factor: 5.948

2.  Evaluation of the new test VERSANT CT/GC DNA 1.0 assay for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae in urine specimens.

Authors:  Antonella Marangoni; Claudio Foschi; Paola Nardini; Antonietta D'Antuono; Nicoletta Banzola; Antonietta Di Francesco; Roberto Cevenini
Journal:  J Clin Lab Anal       Date:  2012-02       Impact factor: 2.352

3.  Optimized testing for C. trachomatis DNA in synovial fluid samples in clinical practice.

Authors:  J Freise; I Bernau; S Meier; H Zeidler; J G Kuipers
Journal:  Z Rheumatol       Date:  2015-11       Impact factor: 1.372

4.  Is there evidence of the new variant Chlamydia trachomatis in the United States?

Authors:  Helen Won; Padmini Ramachandran; Richard Steece; Barbara Van Der Pol; Jeanne Moncada; Julius Schachter; Charlotte Gaydos
Journal:  Sex Transm Dis       Date:  2013-05       Impact factor: 2.830

5.  A multiplexed microfluidic PCR assay for sensitive and specific point-of-care detection of Chlamydia trachomatis.

Authors:  Deborah Dean; Rosemary S Turingan; Hans-Ulrich Thomann; Anna Zolotova; James Rothschild; Sandeep J Joseph; Timothy D Read; Eugene Tan; Richard F Selden
Journal:  PLoS One       Date:  2012-12-14       Impact factor: 3.240

6.  Urine-based testing for Chlamydia trachomatis among young adults in a population-based survey in Croatia: feasibility and prevalence.

Authors:  Ivana Božičević; Ivana Grgić; Snježana Židovec-Lepej; Jurja-Ivana Čakalo; Sanja Belak-Kovačević; Aleksandar Štulhofer; Josip Begovac
Journal:  BMC Public Health       Date:  2011-04-14       Impact factor: 3.295

7.  Molecular Diagnosis of Sexually Transmitted Chlamydia trachomatis in the United States.

Authors:  April L Harkins; Erik Munson
Journal:  ISRN Obstet Gynecol       Date:  2011-06-12

8.  Analysis of laboratory testing results collected in an enhanced chlamydia surveillance system in Australia, 2008-2010.

Authors:  Wayne Dimech; Megan S C Lim; Caroline Van Gemert; Rebecca Guy; Douglas Boyle; Basil Donovan; Margaret Hellard
Journal:  BMC Infect Dis       Date:  2014-06-12       Impact factor: 3.090

9.  Precision of the Abbott RealTime Assay in the Detection of Ocular Chlamydia trachomatis in a Trachoma-Endemic Area of Ethiopia.

Authors:  Kieran S O'Brien; Ambahun Chernet; Jeanne Moncada; Julius Schachter; Paul M Emerson; Scott D Nash; Melsew Chanyalew; Zerihun Tadesse; Zhaoxia Zhou; Charles E McCulloch; Thomas M Lietman; Jeremy D Keenan
Journal:  Am J Trop Med Hyg       Date:  2020-05-07       Impact factor: 2.345

10.  Rapid screening for Chlamydia trachomatis infection by detecting α-mannosidase activity in urogenital tract specimens.

Authors:  Ze-yu Wang; Guang-yu Fu; Shan-mei Wang; Dong-chun Qin; Zhong-quan Wang; Jing Cui
Journal:  BMC Infect Dis       Date:  2013-01-24       Impact factor: 3.090

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.