Literature DB >> 20006913

Evaluation of formal methods in hip joint center assessment: an in vitro analysis.

Nicola Lopomo1, Lei Sun, Stefano Zaffagnini, Giovanni Giordano, Marc R Safran.   

Abstract

BACKGROUND: The hip joint center is a fundamental landmark in the identification of lower limb mechanical axis; errors in its location lead to substantial inaccuracies both in joint reconstruction and in gait analysis. Actually in Computer Aided Surgery functional non-invasive procedures have been tested in identifying this landmark, but an anatomical validation is scarcely discussed.
METHODS: A navigation system was used to acquire data on eight cadaveric hips. Pivoting functional maneuver and hip joint anatomy were analyzed. Two functional methods - both with and without using the pelvic tracker - were evaluated: specifically a sphere fit method and a transformation techniques. The positions of the estimated centers with respect to the anatomical center of the femoral head, the influence of this deviation on the kinematic assessment and on the identification of femoral mechanical axis were analyzed.
FINDINGS: We found that the implemented transformation technique was the most reliable estimation of hip joint center, introducing a - Mean (SD) - difference of 1.6 (2.7) mm from the anatomical center with the pelvic tracker, whereas sphere fit method without it demonstrated the lowest accuracy with 25.2 (18.9) mm of deviation. Otherwise both the methods reported similar accuracy (<3mm of deviation).
INTERPRETATION: The functional estimations resulted in the best case to be in an average of less than 2mm from the anatomical center, which corresponds to angular deviations of the femoral mechanical axis smaller than 1.7 (1.3) degrees and negligible errors in kinematic assessment of angular displacements.

Mesh:

Year:  2009        PMID: 20006913     DOI: 10.1016/j.clinbiomech.2009.11.008

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  8 in total

1.  Sensitivity of hip tissues contact evaluation to the methods used for estimating the hip joint center of rotation.

Authors:  Ehsan Arbabi; Jerome Schmid; Ronan Boulic; Daniel Thalmann; Nadia Magnenat-Thalmann
Journal:  Med Biol Eng Comput       Date:  2012-02-29       Impact factor: 2.602

2.  The accuracy of the use of functional hip motions on localization of the center of the hip.

Authors:  Andrew D Speirs; Daniel L Benoit; Mélanie L Beaulieu; Mario Lamontagne; Paul E Beaulé
Journal:  HSS J       Date:  2012-09-07

3.  No difference in accuracy between pinless and conventional computer-assisted surgery in total knee arthroplasty.

Authors:  C Baier; G Maderbacher; H R Springorum; F Zeman; W Fitz; J Schaumburger; J Grifka; J Beckmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-01       Impact factor: 4.342

4.  Applications of computer navigation in sports medicine knee surgery: an evidence-based review.

Authors:  Simon W Young; Marc R Safran; Mark Clatworthy
Journal:  Curr Rev Musculoskelet Med       Date:  2013-06

5.  In vitro hip testing in the International Society of Biomechanics coordinate system.

Authors:  Richard J van Arkel; Jonathan R T Jeffers
Journal:  J Biomech       Date:  2016-10-29       Impact factor: 2.712

6.  Evaluation of functional methods of joint centre determination for quasi-planar movement.

Authors:  Lin Meng; Craig Childs; Arjan Buis
Journal:  PLoS One       Date:  2019-01-17       Impact factor: 3.240

7.  The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty.

Authors:  Kwangkyoun Kim; Jungsung Kim; Dokyoung Lee; Sohui Lim; Jiyoon Eom
Journal:  Knee Surg Relat Res       Date:  2019-03-01

8.  Validation of an optical, computer-assisted technique for intraoperative tracking of 3-dimensional canine stifle joint motion.

Authors:  Cecilia Signorelli; Filippo Cinti; Stefano Zaffagnini; Luciano Pisoni; Nicola Francesco Lopomo
Journal:  Open Vet J       Date:  2020-03-22
  8 in total