An innovative application of a small-scale motion analysis technique to quantify human skin deformation in vivo.

Jamaluddin Mahmud1, Cathy A Holt, Sam L Evans.   

Abstract

This study highlights a new experimental method developed to measure full-field deformation of human skin in vivo. The technique uses a small-scale Qualisys (Sweden) 3D motion capture system and an array of reflective markers placed on the forearm of five healthy volunteers. A load of up to 1.5N was applied to induce skin deformation by pulling a fine wire attached to the centre of the marker configuration. Loading and marker displacements were recorded simultaneously. 3D marker trajectory data was generated for three different load directions. Tests were repeated to investigate accuracy and repeatability. Calibration results indicate the accuracy of the motion capture system with an average residual of 0.05 mm. The procedure was found to be repeatable and accurate for five repeated tests of measured displacements with a maximum variance of 5%. Experimental data are presented to demonstrate robustness and the ability to produce significant outputs. For all five subjects, at 1N load, the mean and standard deviations of skin axial and lateral displacements were found to be 11.7+/-1.6mm and 12.3+/-3.3mm, respectively. The axial displacements ratio (u(90)/u(0)) ranges from 0.63 to 1.45 with mean+/-standard deviation of 0.982+/-0.34 and 0.982+/-0.32 for left and right arms, respectively. The experiments generated useful and accurate data that can be used to study the viscoelastic, hyperelastic or anisotropic behaviour of human skin. The measured displacements will be analysed further to determine the mechanical properties of skin using inverse Finite Element Analysis and Ogden model. Crown Copyright (c) 2009. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 20005519     DOI: 10.1016/j.jbiomech.2009.11.009

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  5 in total

1.  Mechanical assessment of two different methods of tripling hamstring tendons when using suspensory fixation.

Authors:  Martyn Snow; William Cheung; Jamaluddin Mahmud; Sam Evans; Catherine Holt; Bin Wang; Mahmoud Chizari
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-21       Impact factor: 4.342

Review 2.  Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and foreign body response-part II: examples and application.

Authors:  Kristen L Helton; Buddy D Ratner; Natalie A Wisniewski
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

3.  Multi-view stereo analysis reveals anisotropy of prestrain, deformation, and growth in living skin.

Authors:  Adrián Buganza Tepole; Michael Gart; Chad A Purnell; Arun K Gosain; Ellen Kuhl
Journal:  Biomech Model Mechanobiol       Date:  2015-01-30

4.  Physical human-robot interaction of an active pelvis orthosis: toward ergonomic assessment of wearable robots.

Authors:  Nicolò d'Elia; Federica Vanetti; Marco Cempini; Guido Pasquini; Andrea Parri; Marco Rabuffetti; Maurizio Ferrarin; Raffaele Molino Lova; Nicola Vitiello
Journal:  J Neuroeng Rehabil       Date:  2017-04-14       Impact factor: 4.262

5.  Effects of Kinesio taping on skin deformation during knee flexion and extension: a preliminary study.

Authors:  Fei He; Xiaoxuan Wang; Menglian Yu; Yiyi Chen; Bo Yu; Jianqiang Lu
Journal:  BMC Musculoskelet Disord       Date:  2022-02-28       Impact factor: 2.362

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.