Literature DB >> 19996756

Evaluation of a modified Stejskal-Tanner diffusion encoding scheme, permitting a marked reduction in TE, in diffusion-weighted imaging of stroke patients at 3 T.

John N Morelli1, Val M Runge, Thorsten Feiweier, John E Kirsch, Kenneth W Williams, Ulrike I Attenberger.   

Abstract

PURPOSE: To evaluate a modified Stejskal-Tanner diffusion gradient pulsing scheme that applies diffusion encoding during the entire time between the 2 requisite radiofrequency pulses, shortening TE.
MATERIALS AND METHODS: Seventeen healthy volunteers and 15 patients with acute and early subacute infarcts were evaluated at 3 T utilizing: a conventional bipolar gradient double spin echo planar imaging diffusion weighted imaging with a parallel imaging factor of 2 (p2) and a modified Stejskal-Tanner short TE (sTE) SE echo planar imaging diffusion weighted imaging with parallel imaging factors of 2, 3, and 4. Signal-to-noise ratio (SNR) and susceptibility-induced spatial distortions were quantified, and a blinded reader ranked scans in terms of susceptibility artifact and overall preference.
RESULTS: The sTE sequence allowed a shortening in TE of 18 to 28 milliseconds versus the standard bipolar gradient sequence. SNRs were generally not significantly different among the sTE scans because of compensation by number of scan averages. By using twice the number of averages, the SNR with the bipolar gradient sequence was not significantly different from that of the sTE sequences in patients. sTE scans with higher parallel imaging factors demonstrated less susceptibility-related artifact. The blinded reader ranked the p3 or p4 sTE scans most preferred and the bipolar gradient scans least or tied for least preferred in every case.
CONCLUSIONS: Utilization of the sTE modified Stejskal-Tanner sequence markedly improves SNR-an increase that may be used with parallel imaging to improve overall scan quality whereas maintaining reasonable scan times and SNR.

Entities:  

Mesh:

Year:  2010        PMID: 19996756     DOI: 10.1097/RLI.0b013e3181c65c11

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  14 in total

1.  Mapping fine-scale anatomy of gray matter, white matter, and trigeminal-root region applying spherical deconvolution to high-resolution 7-T diffusion MRI.

Authors:  Ralf Lützkendorf; Robin M Heidemann; Thorsten Feiweier; Michael Luchtmann; Sebastian Baecke; Jörn Kaufmann; Jörg Stadler; Eike Budinger; Johannes Bernarding
Journal:  MAGMA       Date:  2018-09-17       Impact factor: 2.310

2.  MR with surface coils in the follow-up after endoscopic laser resection for glottic squamous cell carcinoma: feasibility and diagnostic accuracy.

Authors:  Marco Ravanelli; Davide Farina; Paola Rizzardi; Elisa Botturi; Paola Prandolini; Stefano Mangili; Giorgio Peretti; Piero Nicolai; Roberto Maroldi
Journal:  Neuroradiology       Date:  2012-12-22       Impact factor: 2.804

3.  A SEmi-Adiabatic matched-phase spin echo (SEAMS) PINS pulse-pair for B1 -insensitive simultaneous multislice imaging.

Authors:  Rebecca E Feldman; Haisam M Islam; Junqian Xu; Priti Balchandani
Journal:  Magn Reson Med       Date:  2015-03-10       Impact factor: 4.668

Review 4.  Ultra-High-Field MR Neuroimaging.

Authors:  P Balchandani; T P Naidich
Journal:  AJNR Am J Neuroradiol       Date:  2014-12-18       Impact factor: 3.825

5.  The impact of post-processing on spinal cord diffusion tensor imaging.

Authors:  Siawoosh Mohammadi; Patrick Freund; Thorsten Feiweier; Armin Curt; Nikolaus Weiskopf
Journal:  Neuroimage       Date:  2013-01-05       Impact factor: 6.556

6.  Echo planar diffusion-weighted imaging: possibilities and considerations with 12- and 32-channel head coils.

Authors:  John N Morelli; Megan R Saettele; Rajesh A Rangaswamy; Lan Vu; Clint M Gerdes; Wei Zhang; Fei Ai
Journal:  J Clin Imaging Sci       Date:  2012-05-23

7.  Strategies for assessing diffusion anisotropy on the basis of magnetic resonance images: comparison of systematic errors.

Authors:  Saïd Boujraf
Journal:  J Med Signals Sens       Date:  2014-04

8.  Adaptive smoothing of multi-shell diffusion weighted magnetic resonance data by msPOAS.

Authors:  S M A Becker; K Tabelow; S Mohammadi; N Weiskopf; J Polzehl
Journal:  Neuroimage       Date:  2014-03-25       Impact factor: 6.556

Review 9.  Tracking changes following spinal cord injury: insights from neuroimaging.

Authors:  Patrick Freund; Armin Curt; Karl Friston; Alan Thompson
Journal:  Neuroscientist       Date:  2012-06-22       Impact factor: 7.519

10.  High-resolution diffusion kurtosis imaging at 3T enabled by advanced post-processing.

Authors:  Siawoosh Mohammadi; Karsten Tabelow; Lars Ruthotto; Thorsten Feiweier; Jörg Polzehl; Nikolaus Weiskopf
Journal:  Front Neurosci       Date:  2015-01-07       Impact factor: 4.677

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.