Determination of output factors for stereotactic radiosurgery beams.

J Fan1, K Paskalev, L Wang, L Jin, J Li, A Eldeeb, C Ma.   

Abstract

Accurate dosimetry of the narrow beam tends to be difficult to perform due to the absence of lateral electronic equilibrium and the steep dose gradient, as well as the finite size of detectors. Thus, although the high dose rate 6 MV beam on the VARIAN Trilogy accelerator is increasingly utilized for stereotactic radiosurgery (SRS) treatment, there is no general agreement in the SRS beam output factor values among the Trilogy user community. Trilogy SRS beams are confined by cone collimators and the available collimator sizes range from 5 and 10 to 30 mm, in every 2 mm increment. A range of the relative output factors are in clinic use. This variation may impair observations of dose response and optimizations of the prescribed dose. It is necessary to investigate an accurate, easily performable, and detector independent method for the narrow beam output factor measurement. In this study, a scanning beam/scanning chamber method was proposed to overcome the limitation/difficulty of using a relatively large detector in narrow beam output factor measurement. Specifically, for the scanning beam method, multiple narrow beams are used for the dose measurement using a finite size chamber. These multiple scanning beams form an equivalent large uniform field which provides lateral electron equilibrium condition. After the measurement, the contributions from neighboring beams are deconvolved and the value is used for output factor determinations. For a Linac that cannot move a beam laterally, the scanning chamber method can be used to achieve the same result. The output factors determined in such a method were compared to chambers (a 0.015 cc PTW PinPoint ion chamber and a 0.125 cc PTW ion chamber) and film measurement, as well as with Monte Carlo simulation. Film and Monte Carlo results are found to be in excellent agreement with the measurement using the scan beam method. However, the VARIAN recommended output factors measured directly by Wellhöfer CC01 chamber and Scanditronix photon field diode are consistently higher for all the cones. Especially for the 5 mm cone, the difference is more than 10%. Overall, the results suggested that the new method can help overcoming the detector volume averaging effect and the positioning uncertainties, which constitute the major challenge in small radiosurgical beam output factor measurement, and provide reliable output factors.

Mesh:

Substances:

Year:  2009        PMID: 19994537     DOI: 10.1118/1.3232217

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Dosimetry challenges for implementing emerging technologies.

Authors:  Fang-Fang Yin; Mark Oldham; Jing Cai; Qiuwen Wu
Journal:  J Phys Conf Ser       Date:  2010

2.  A procedure to determine the planar integral spot dose values of proton pencil beam spots.

Authors:  Aman Anand; Narayan Sahoo; X Ronald Zhu; Gabriel O Sawakuchi; Falk Poenisch; Richard A Amos; George Ciangaru; Uwe Titt; Kazumichi Suzuki; Radhe Mohan; Michael T Gillin
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

3.  Monte carlo model and output factors of elekta infinity™ 6 and 10 MV photon beam.

Authors:  Sitti Yani; Indra Budiansah; Mohamad Fahdillah Rhani; Freddy Haryanto
Journal:  Rep Pract Oncol Radiother       Date:  2020-04-28

4.  Monte Carlo Dose Calculation - A QA Method for SRT and SBRT Plans in Treating Multiple and Small Metastatic Lesions.

Authors:  Teh Lin; Lu Wang; C-M Charlie Ma
Journal:  J Med Phys       Date:  2022-03-31

5.  Dosimetric characterization of Elekta stereotactic cones.

Authors:  Egor Borzov; Alexander Nevelsky; Raquel Bar-Deroma; Itzhak Orion
Journal:  J Appl Clin Med Phys       Date:  2017-12-20       Impact factor: 2.102

6.  Dosimetric characteristics of the small diameter BrainLab™ cones used for stereotactic radiosurgery.

Authors:  Gocha Khelashvili; James Chu; Aidnag Diaz; Julius Turian
Journal:  J Appl Clin Med Phys       Date:  2012-01-05       Impact factor: 2.102

7.  Measurement of Total Scatter Factor for Stereotactic Cones with Plastic Scintillation Detector.

Authors:  Suresh H Chaudhari; Rishabh Dobhal; Rajesh A Kinhikar; Sudarshan S Kadam; Deepak D Deshpande
Journal:  J Med Phys       Date:  2017 Jan-Mar

8.  Detectors assessment for stereotactic radiosurgery with cones.

Authors:  Nicolas Garnier; Régis Amblard; Rémy Villeneuve; Rodolphe Haykal; Cécile Ortholan; Philippe Colin; Anaïs Gérard; Sarah Belhomme; Franck Mady; Mourad Benabdesselam; Benjamin Serrano
Journal:  J Appl Clin Med Phys       Date:  2018-09-14       Impact factor: 2.102

9.  Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters.

Authors:  Guerda Massillon-J L; Diego Cueva-Prócel; Porfirio Díaz-Aguirre; Miguel Rodríguez-Ponce; Flor Herrera-Martínez
Journal:  PLoS One       Date:  2013-05-09       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.