Literature DB >> 1998834

Determinations of organ doses and effective dose equivalents from computed tomographic examination.

K Nishizawa1, T Maruyama, M Takayama, M Okada, J Hachiya, Y Furuya.   

Abstract

The organ or tissue doses were determined with a phantom measurement for 12 types of CT scanners widely used in Japan. Two types of thermoluminescent dosimeters were used for the dose determinations in a Rando woman phantom. The effective dose equivalents recommended by the International Commission on Radiological Protection were calculated using the measured organ or tissue doses. It was found that the CT scanners currently available give quite different organ or tissue doses. When selecting the optimum technical factors for scanning, therefore, it is important to take into consideration the balance of the image quality and the radiation exposure to patients.

Entities:  

Mesh:

Year:  1991        PMID: 1998834     DOI: 10.1259/0007-1285-64-757-20

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  8 in total

1.  CT of the head by use of reduced current and kilovoltage: relationship between image quality and dose reduction.

Authors:  M Cohnen; H Fischer; J Hamacher; E Lins; R Kötter; U Mödder
Journal:  AJNR Am J Neuroradiol       Date:  2000-10       Impact factor: 3.825

2.  Radiation dose to the lens using different temporal bone CT scanning protocols.

Authors:  Y Niu; Z Wang; Y Liu; Z Liu; V Yao
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-05       Impact factor: 3.825

3.  Radioprotection to the eye during CT scanning.

Authors:  K D Hopper; J D Neuman; S H King; A R Kunselman
Journal:  AJNR Am J Neuroradiol       Date:  2001 Jun-Jul       Impact factor: 3.825

4.  Is the nuclear medicine community too self-critical?

Authors:  A Bossuyt
Journal:  Eur J Nucl Med       Date:  1994-07

5.  Radiation dose evaluation in 64-slice CT examinations with adult and paediatric anthropomorphic phantoms.

Authors:  K Fujii; T Aoyama; C Yamauchi-Kawaura; S Koyama; M Yamauchi; S Ko; K Akahane; K Nishizawa
Journal:  Br J Radiol       Date:  2009-12       Impact factor: 3.039

6.  Patient-specific CT dosimetry calculation: a feasibility study.

Authors:  Thomas Fearon; Huchen Xie; Jason Y Cheng; Holly Ning; Ying Zhuge; Robert W Miller
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

7.  Effective and organ doses using helical 4DCT for thoracic and abdominal therapies.

Authors:  Yuka Matsuzaki; Keisuke Fujii; Motoki Kumagai; Ichiro Tsuruoka; Shinichiro Mori
Journal:  J Radiat Res       Date:  2013-04-19       Impact factor: 2.724

8.  Estimation of patient organ doses from CT examinations in Tanzania.

Authors:  Justin E Ngaile; Peter K Msaki
Journal:  J Appl Clin Med Phys       Date:  2006-08-24       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.