Literature DB >> 1997572

Reliability of isometric hip abductor torques during examiner- and belt-resisted tests.

J F Kramer1, M D Vaz, A A Vandervoort.   

Abstract

The purposes of this study were to determine the test-retest reliability of isometric hip abductor torques in elderly females, to compare two assessment protocols, and to compare the performances of elderly and young females. Twenty elderly and 20 young women were tested on two occasions. During the examiner-resisted test the examiner provided the resistance, and during the belt-resisted test the subject's contralateral leg provided the resistance while the examiner positioned the dynamometer. A four-way ANOVA indicated no occasion effects (p greater than .05). Within each group, similar torques were produced by both legs (p greater than .05). Test-retest intraclass reliability coefficients were good-to-high, ranging from 0.84 to 0.98 for the eight combinations of group-method-leg. The elderly females produced 61% of the torques produced by young females (p less than .01), and the examiner-resisted method produced 65% of the torques produced using the belt-resisted method (p less than .01). The belt-resisted method required less physical effort on the part of the tester, provided greater stabilization of the pelvis, and was preferred by 95% of the subjects.

Entities:  

Mesh:

Year:  1991        PMID: 1997572     DOI: 10.1093/geronj/46.2.m47

Source DB:  PubMed          Journal:  J Gerontol        ISSN: 0022-1422


  11 in total

1.  Reliability of stabilised commercial dynamometers for measuring hip abduction strength: a pilot study.

Authors:  P Click Fenter; J W Bellew; T A Pitts; R E Kay
Journal:  Br J Sports Med       Date:  2003-08       Impact factor: 13.800

2.  Hip- and knee-strength assessments using a hand-held dynamometer with external belt-fixation are inter-tester reliable.

Authors:  Kristian Thorborg; Thomas Bandholm; Per Hölmich
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-07-07       Impact factor: 4.342

3.  RELIABILITY, COMPARABILITY, AND VALIDITY OF FOOT INVERSION AND EVERSION STRENGTH MEASUREMENTS USING A HAND-HELD DYNAMOMETER.

Authors:  Martin Alfuth; Magali Murielle Hahm
Journal:  Int J Sports Phys Ther       Date:  2016-02

4.  Hand-held dynamometry fixated with a tripod is reliable for assessment of back extensor strength in women with osteoporosis.

Authors:  G Valentin; T Maribo
Journal:  Osteoporos Int       Date:  2014-05-28       Impact factor: 4.507

5.  Reliability and Validity of the Belt-Stabilized Handheld Dynamometer in Hip- and Knee-Strength Tests.

Authors:  Jaqueline Martins; Janaina Rodrigues da Silva; Marcelo Rodrigues Barbosa da Silva; Débora Bevilaqua-Grossi
Journal:  J Athl Train       Date:  2017-08-08       Impact factor: 2.860

6.  DYNAMIC HIP ADDUCTION, ABDUCTION AND ABDOMINAL EXERCISES FROM THE HOLMICH GROIN-INJURY PREVENTION PROGRAM ARE INTENSE ENOUGH TO BE CONSIDERED STRENGTHENING EXERCISES - A CROSS-SECTIONAL STUDY.

Authors:  Kasper Krommes; Thomas Bandholm; Markus D Jakobsen; Lars L Andersen; Andreas Serner; Per Hölmich; Kristian Thorborg
Journal:  Int J Sports Phys Ther       Date:  2017-06

7.  Reliability of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer.

Authors:  Terumi Suzuki
Journal:  J Phys Ther Sci       Date:  2015-03-31

8.  Intra-rater reliability of hip abductor isometric strength testing in a standing position in older fallers and non-fallers.

Authors:  Anne-Violette Bruyneel; Simone C Gafner; Serge Ferrari; Gabriel Gold; Dominique Monnin; Philippe Terrier; Caroline H Bastiaenen; Lara Allet
Journal:  Eur Rev Aging Phys Act       Date:  2018-08-07       Impact factor: 3.878

9.  NORMATIVE ISOMETRIC HIP MUSCLE FORCE VALUES ASSESSED BY A MANUAL DYNAMOMETER.

Authors:  Glauber Alvarenga; Henry Dan Kiyomoto; Emília Cardoso Martinez; Giancarlo Polesello; Vera Lúcia Dos Santos Alves
Journal:  Acta Ortop Bras       Date:  2019 Mar-Apr       Impact factor: 0.513

10.  Pilot study: can older inactive adults learn how to reach the required intensity of physical activity guideline?

Authors:  Danielle R Bouchard; Marie-France Langlois; Katherine Boisvert-Vigneault; Paul Farand; Mathieu Paulin; Jean-Patrice Baillargeon
Journal:  Clin Interv Aging       Date:  2013-04-30       Impact factor: 4.458

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.