Literature DB >> 19964794

Detection of intraventricular blood using EIT in a neonatal piglet model.

R J Sadleir1, Te Tang, Aaron S Tucker, Peggy Borum, Michael Weiss.   

Abstract

We have developed a sensitive EIT protocol for detection of intraventricular bleeding. A common model of human neonates is the neonatal piglet. We used our method to test the sensitivity of our method and device to small amounts of blood-like fluid injected near the left and right ventricles of a piglet cadaver. Comparing blood-like fluid detection in open an closed piglet skulls, we found that we could detect amounts of blood less than 0.5 ml, which is smaller than that required for our target of detecting grade II intraventricular hemorrhages in human neonates.

Entities:  

Mesh:

Year:  2009        PMID: 19964794      PMCID: PMC3063553          DOI: 10.1109/IEMBS.2009.5334510

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  16 in total

1.  Electrical impedance tomography of human brain activity with a two-dimensional ring of scalp electrodes.

Authors:  A T Tidswell; A Gibson; R H Bayford; D S Holder
Journal:  Physiol Meas       Date:  2001-02       Impact factor: 2.833

2.  Three-dimensional electrical impedance tomography of human brain activity.

Authors:  T Tidswell; A Gibson; R H Bayford; D S Holder
Journal:  Neuroimage       Date:  2001-02       Impact factor: 6.556

Review 3.  Health issues in survivors of prematurity.

Authors:  Jackie York; Michael DeVoe
Journal:  South Med J       Date:  2002-09       Impact factor: 0.954

4.  The effect of layers in imaging brain function using electrical impedance tomograghy.

Authors:  A D Liston; R H Bayford; D S Holder
Journal:  Physiol Meas       Date:  2004-02       Impact factor: 2.833

5.  Incidence and evolution of subependymal and intraventricular hemorrhage: a study of infants with birth weights less than 1,500 gm.

Authors:  L A Papile; J Burstein; R Burstein; H Koffler
Journal:  J Pediatr       Date:  1978-04       Impact factor: 4.406

6.  The electrical conductivity of human cerebrospinal fluid at body temperature.

Authors:  S B Baumann; D R Wozny; S K Kelly; F M Meno
Journal:  IEEE Trans Biomed Eng       Date:  1997-03       Impact factor: 4.538

7.  The specific resistance of biological material--a compendium of data for the biomedical engineer and physiologist.

Authors:  L A Geddes; L E Baker
Journal:  Med Biol Eng       Date:  1967-05

8.  The effect of the skull of low-birthweight neonates on applied potential tomography imaging of centralised resistivity changes.

Authors:  F J McArdle; B H Brown; R G Pearse; D C Barber
Journal:  Clin Phys Physiol Meas       Date:  1988

9.  Impedance imaging in the newborn.

Authors:  D Murphy; P Burton; R Coombs; L Tarassenko; P Rolfe
Journal:  Clin Phys Physiol Meas       Date:  1987

Review 10.  Practice parameter: neuroimaging of the neonate: report of the Quality Standards Subcommittee of the American Academy of Neurology and the Practice Committee of the Child Neurology Society.

Authors:  L R Ment; H S Bada; P Barnes; P E Grant; D Hirtz; L A Papile; J Pinto-Martin; M Rivkin; T L Slovis
Journal:  Neurology       Date:  2002-06-25       Impact factor: 9.910

View more
  4 in total

1.  In vivo quantification of intraventricular hemorrhage in a neonatal piglet model using an EEG-layout based electrical impedance tomography array.

Authors:  Te Tang; Michael D Weiss; Peggy Borum; Sergei Turovets; Don Tucker; Rosalind Sadleir
Journal:  Physiol Meas       Date:  2016-05-20       Impact factor: 2.833

2.  Intracranial electrical impedance tomography: a method of continuous monitoring in an animal model of head trauma.

Authors:  Preston K Manwaring; Karen L Moodie; Alexander Hartov; Kim H Manwaring; Ryan J Halter
Journal:  Anesth Analg       Date:  2013-07-10       Impact factor: 5.108

3.  Speckle contrast diffuse correlation tomography of cerebral blood flow in perinatal disease model of neonatal piglets.

Authors:  Chong Huang; Siavash Mazdeyasna; Mehrana Mohtasebi; Kathryn E Saatman; Qiang Cheng; Guoqiang Yu; Lei Chen
Journal:  J Biophotonics       Date:  2021-01-03       Impact factor: 3.207

4.  Real-Time Detection of Hemothorax and Monitoring its Progression in a Piglet Model by Electrical Impedance Tomography: A Feasibility Study.

Authors:  Lin Yang; Chao Zhang; Wenbo Liu; Hang Wang; Junying Xia; Benyuan Liu; Xuetao Shi; Xiuzhen Dong; Feng Fu; Meng Dai
Journal:  Biomed Res Int       Date:  2020-02-27       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.