Literature DB >> 19963625

Non-contact respiratory rate measurement validation for hospitalized patients.

Amy D Droitcour1, Todd B Seto, Byung-Kwon Park, Shuhei Yamada, Alex Vergara, Charles El Hourani, Tommy Shing, Andrea Yuen, Victor M Lubecke, Olga Boric-Lubecke.   

Abstract

This paper presents the first clinical results for validating the accuracy of respiratory rate obtained for hospitalized patients using a non-contact, low power 2.4 GHz Doppler radar system. Twenty-four patients were measured in this study. The respiratory rate accuracy was benchmarked against the respiratory rate obtained using Welch Allyn Propaq Encore model 242, the Embla Embletta system with Universal XactTrace respiratory effort sensor and Somnologica for Embletta software, and by counting chest excursions. The 95% limits of agreement between the Doppler radar and reference measurements fall within +/-5 breaths per minute.

Entities:  

Mesh:

Year:  2009        PMID: 19963625      PMCID: PMC4313750          DOI: 10.1109/IEMBS.2009.5332635

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  6 in total

1.  Respiratory rate measurement in adults--how reliable is it?

Authors:  W S Lim; S M Carty; J T Macfarlane; R E Anthony; J Christian; K S Dakin; P M Dennis
Journal:  Respir Med       Date:  2002-01       Impact factor: 3.415

Review 2.  Microwave sensing of physiological movement and volume change: a review.

Authors:  J C Lin
Journal:  Bioelectromagnetics       Date:  1992       Impact factor: 2.010

3.  Monitoring variations of biological impedances at microwave frequencies.

Authors:  A Thansandote; S S Stuchly; A M Smith; J S Wight
Journal:  IEEE Trans Biomed Eng       Date:  1983-09       Impact factor: 4.538

4.  A microprocessor-based noninvasive arterial pulse wave analyzer.

Authors:  J Y Lee; J C Lin
Journal:  IEEE Trans Biomed Eng       Date:  1985-06       Impact factor: 4.538

5.  The identification of risk factors for cardiac arrest and formulation of activation criteria to alert a medical emergency team.

Authors:  Timothy J Hodgetts; Gary Kenward; Ioannis G Vlachonikolis; Susan Payne; Nicolas Castle
Journal:  Resuscitation       Date:  2002-08       Impact factor: 5.262

6.  Association between clinically abnormal observations and subsequent in-hospital mortality: a prospective study.

Authors:  Michael Buist; Stephen Bernard; Tuan V Nguyen; Gaye Moore; Jeremy Anderson
Journal:  Resuscitation       Date:  2004-08       Impact factor: 5.262

  6 in total
  11 in total

1.  Remote monitoring of breathing dynamics using infrared thermography.

Authors:  Carina Barbosa Pereira; Xinchi Yu; Michael Czaplik; Rolf Rossaint; Vladimir Blazek; Steffen Leonhardt
Journal:  Biomed Opt Express       Date:  2015-10-16       Impact factor: 3.732

2.  Acoustic sensor versus electrocardiographically derived respiratory rate in unstable trauma patients.

Authors:  Shiming Yang; Ashley Menne; Peter Hu; Lynn Stansbury; Cheng Gao; Nicolas Dorsey; William Chiu; Stacy Shackelford; Colin Mackenzie
Journal:  J Clin Monit Comput       Date:  2016-06-07       Impact factor: 2.502

3.  Algorithms for Monitoring Heart Rate and Respiratory Rate From the Video of a User's Face.

Authors:  Shourjya Sanyal; Koushik Kumar Nundy
Journal:  IEEE J Transl Eng Health Med       Date:  2018-04-12       Impact factor: 3.316

4.  Estimation of breathing rate in thermal imaging videos: a pilot study on healthy human subjects.

Authors:  Carina Barbosa Pereira; Xinchi Yu; Michael Czaplik; Vladimir Blazek; Boudewijn Venema; Steffen Leonhardt
Journal:  J Clin Monit Comput       Date:  2016-10-24       Impact factor: 2.502

5.  Neonatal non-contact respiratory monitoring based on real-time infrared thermography.

Authors:  Abbas K Abbas; Konrad Heimann; Katrin Jergus; Thorsten Orlikowsky; Steffen Leonhardt
Journal:  Biomed Eng Online       Date:  2011-10-20       Impact factor: 2.819

Review 6.  Novel Flexible Wearable Sensor Materials and Signal Processing for Vital Sign and Human Activity Monitoring.

Authors:  Amir Servati; Liang Zou; Z Jane Wang; Frank Ko; Peyman Servati
Journal:  Sensors (Basel)       Date:  2017-07-13       Impact factor: 3.576

7.  Estimating Respiratory Rate in Post-Anesthesia Care Unit Patients Using Infrared Thermography: An Observational Study.

Authors:  Nadine Hochhausen; Carina Barbosa Pereira; Steffen Leonhardt; Rolf Rossaint; Michael Czaplik
Journal:  Sensors (Basel)       Date:  2018-05-18       Impact factor: 3.576

8.  Physiological Validation of an Airborne Ultrasound Based Surface Motion Camera for a Contactless Characterization of Breathing Pattern in Humans.

Authors:  Marie-Cécile Niérat; Pierantonio Laveneziana; Bruno-Pierre Dubé; Pavel Shirkovskiy; Ros-Kiri Ing; Thomas Similowski
Journal:  Front Physiol       Date:  2019-05-29       Impact factor: 4.566

9.  Monitoring of Cardiorespiratory Signals Using Thermal Imaging: A Pilot Study on Healthy Human Subjects.

Authors:  Carina Barbosa Pereira; Michael Czaplik; Vladimir Blazek; Steffen Leonhardt; Daniel Teichmann
Journal:  Sensors (Basel)       Date:  2018-05-13       Impact factor: 3.576

Review 10.  The Psychophysiological Implications of Soundscape: A Systematic Review of Empirical Literature and a Research Agenda.

Authors:  Mercede Erfanian; Andrew J Mitchell; Jian Kang; Francesco Aletta
Journal:  Int J Environ Res Public Health       Date:  2019-09-21       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.