Literature DB >> 19963267

Quantitative analysis of the tissue response to chronically implanted microwire electrodes in rat cortex.

Brent D Winslow1, Patrick A Tresco.   

Abstract

Several hypotheses have been proposed to explain how the brain tissue reaction to single unit recording electrodes influences biocompatibility including progressive changes in the spatial distribution of reactive astrocytes, and the loss of neurons over the indwelling period. To examine these hypotheses, the spatial distribution of biomarkers associated with the foreign body response to insulated microwires placed in rat cerebral cortex was analyzed 2, 4, and 12 weeks after implantation using quantitative methods. We observed a stereotypical tissue response that was similar in some aspects to that previously reported for penetrating planar silicon microelectrode arrays with some specific differences including an overall lower degree of cortical tissue reactivity. While we found no evidence that reactive gliosis increases over time or that neuronal loss is progressive, we did find evidence of persistent inflammation and enhanced BBB permeability at the electrode brain tissue interface that extended over the 3 month indwelling period and that exhibited more animal to animal variability at 3 months than at 2 and 4 weeks. (c) 2009 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19963267     DOI: 10.1016/j.biomaterials.2009.11.049

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  68 in total

1.  Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies.

Authors:  J P Harris; J R Capadona; R H Miller; B C Healy; K Shanmuganathan; S J Rowan; C Weder; D J Tyler
Journal:  J Neural Eng       Date:  2011-11-02       Impact factor: 5.379

2.  Toward guiding principles for the design of biologically-integrated electrodes for the central nervous system.

Authors:  Cort H Thompson; Ti'Air E Riggins; Paras R Patel; Cynthia A Chestek; Wen Li; Erin Purcell
Journal:  J Neural Eng       Date:  2020-03-12       Impact factor: 5.379

3.  Amorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording.

Authors:  Felix Deku; Yarden Cohen; Alexandra Joshi-Imre; Aswini Kanneganti; Timothy J Gardner; Stuart F Cogan
Journal:  J Neural Eng       Date:  2018-02       Impact factor: 5.379

Review 4.  Physiological properties of brain-machine interface input signals.

Authors:  Marc W Slutzky; Robert D Flint
Journal:  J Neurophysiol       Date:  2017-06-14       Impact factor: 2.714

5.  Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings.

Authors:  Paras R Patel; Kyounghwan Na; Huanan Zhang; Takashi D Y Kozai; Nicholas A Kotov; Euisik Yoon; Cynthia A Chestek
Journal:  J Neural Eng       Date:  2015-06-02       Impact factor: 5.379

6.  Electrodeposited platinum-iridium coating improves in vivo recording performance of chronically implanted microelectrode arrays.

Authors:  Isaac R Cassar; Chunxiu Yu; Jaydeep Sambangi; Curtis D Lee; John J Whalen; Artin Petrossians; Warren M Grill
Journal:  Biomaterials       Date:  2019-03-18       Impact factor: 12.479

7.  Cuprizone-induced oligodendrocyte loss and demyelination impairs recording performance of chronically implanted neural interfaces.

Authors:  Steven M Wellman; Kelly Guzman; Kevin C Stieger; Lauren E Brink; Sadhana Sridhar; Mitchell T Dubaniewicz; Lehong Li; Franca Cambi; Takashi D Y Kozai
Journal:  Biomaterials       Date:  2020-02-06       Impact factor: 12.479

8.  The Effect of Residual Endotoxin Contamination on the Neuroinflammatory Response to Sterilized Intracortical Microelectrodes.

Authors:  Madhumitha Ravikumar; Daniel J Hageman; William H Tomaszewski; Gabriella M Chandra; John L Skousen; Jeffrey R Capadona
Journal:  J Mater Chem B       Date:  2014-05-07       Impact factor: 6.331

9.  Astrocytes specifically remove surface-adsorbed fibrinogen and locally express chondroitin sulfate proteoglycans.

Authors:  Tony W Hsiao; Vimal P Swarup; Balagurunathan Kuberan; Patrick A Tresco; Vladimir Hlady
Journal:  Acta Biomater       Date:  2013-03-14       Impact factor: 8.947

10.  Chronic intracortical microelectrode arrays induce non-uniform, depth-related tissue responses.

Authors:  Andrew J Woolley; Himanshi A Desai; Kevin J Otto
Journal:  J Neural Eng       Date:  2013-02-21       Impact factor: 5.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.