Literature DB >> 19961390

Zirconium dioxide implant abutments for posterior single-tooth replacement: first results.

Frank P Nothdurft1, Peter R Pospiech.   

Abstract

BACKGROUND: Prefabricated implant abutments made of zirconium dioxide (yttria-stabilized polycrystalline tetragonal zirconia; Y-TZP) have proved to be useful in the esthetically demanding anterior region and may also be useful for premolar and molar replacement because of their obvious positive impact on the health of peri-implant soft tissues.
METHODS: Forty screw implants were inserted in the posterior region of 24 patients and provided with prefabricated all-ceramic abutments made of zirconium dioxide Y-TZP. Zirconia-based crowns were used as superstructures. The following parameters were used to document the state of soft tissue: the modified plaque index (mPI), sulcus fluid flow rate (SFFR), modified sulcus bleeding index (mSBI), and probing depth (PD). Additionally, implant stability was measured using an electronic mobility testing device.
RESULTS: All implants (N = 40) followed up after 6 months in function were osseointegrated and showed good stability. In the presence of good oral hygiene (mPI: 0.3), the parameters SFFR (16) and mSBI (0.7) were indicative of stable and healthy soft tissue. The mean PD was highest at the distal points of measurement (2.4 mm) and was generally at a low level. Neither implant loss nor crown fractures occurred. Chipping of parts of the veneering ceramic was registered in three cases (7.5%).
CONCLUSIONS: After 6 months in function, no mechanical failure was registered in any of the all-ceramic abutments. On clinical investigation, the peri-implant soft tissues were largely healthy and devoid of inflammation.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19961390     DOI: 10.1902/jop.2009.090274

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  3 in total

1.  Comparison of implant versus tooth-supported zirconia-based single crowns in a split-mouth design: a 4-year clinical follow-up study.

Authors:  Mustafa Barış Güncü; Umut Cakan; Guliz Aktas; Güliz Nigar Güncü; Şenay Canay
Journal:  Clin Oral Investig       Date:  2016-02-29       Impact factor: 3.573

2.  Fracture behavior of zirconia implant abutments is influenced by superstructure-geometry.

Authors:  Frank P Nothdurft; Konrad Neumann; Andreas W Knauber
Journal:  Clin Oral Investig       Date:  2013-09-20       Impact factor: 3.573

Review 3.  Clinical reliability of zirconium abutment in implant restorations in the English and Korean literature.

Authors:  Su-Been Yu; Bong-Gyu Song; Kyeong-Jun Cheon; Ju-Won Kim; Young-Hee Kim; Byoung-Eun Yang
Journal:  Maxillofac Plast Reconstr Surg       Date:  2018-09-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.