Literature DB >> 19961219

Combined contactless conductometric, photometric, and fluorimetric single point detector for capillary separation methods.

Markéta Ryvolová1, Jan Preisler, Frantisek Foret, Peter C Hauser, Pavel Krásenský, Brett Paull, Mirek Macka.   

Abstract

This work for the first time combines three on-capillary detection methods, namely, capacitively coupled contactless conductometric (C(4)D), photometric (PD), and fluorimetric (FD), in a single (identical) point of detection cell, allowing concurrent measurements at a single point of detection for use in capillary electrophoresis, capillary electrochromatography, and capillary/nanoliquid chromatography. The novel design is based on a standard 6.3 mm i.d. fiber-optic SMA adapter with a drilled opening for the separation capillary to go through, to which two concentrically positioned C(4)D detection electrodes with a detection gap of 7 mm were added on each side acting simultaneously as capillary guides. The optical fibers in the SMA adapter were used for the photometric signal (absorbance), and another optical fiber at a 45 degrees angle to the capillary was applied to collect the emitted light for FD. Light emitting diodes (255 and 470 nm) were used as light sources for the PD and FD detection modes. LOD values were determined under flow-injection conditions to exclude any stacking effects: For the 470 nm LED limits of detection (LODs) for FD and PD were for fluorescein (1 x 10(-8) mol/L) and tartrazine (6 x 10(-6) mol/L), respectively, and the LOD for the C(4)D was for magnesium chloride (5 x 10(-7) mol/L). The advantage of the three different detection signals in a single point is demonstrated in capillary electrophoresis using model mixtures and samples including a mixture of fluorescent and nonfluorescent dyes and common ions, underivatized amino acids, and a fluorescently labeled digest of bovine serum albumin.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19961219     DOI: 10.1021/ac902376v

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

Review 1.  Recent developments in instrumentation for capillary electrophoresis and microchip-capillary electrophoresis.

Authors:  Jessica L Felhofer; Lucas Blanes; Carlos D Garcia
Journal:  Electrophoresis       Date:  2010-08       Impact factor: 3.535

Review 2.  Contactless impedance sensors and their application to flow measurements.

Authors:  František Opekar; Petr Tůma; Karel Stulík
Journal:  Sensors (Basel)       Date:  2013-02-27       Impact factor: 3.576

3.  Sensitive, selective analysis of selenium oxoanions using microchip electrophoresis with contact conductivity detection.

Authors:  Scott D Noblitt; Lucian C Staicu; Christopher J Ackerson; Charles S Henry
Journal:  Anal Chem       Date:  2014-07-29       Impact factor: 6.986

4.  Dual-Purpose Photometric-Conductivity Detector for Simultaneous and Sequential Measurements in Flow Analysis.

Authors:  Thitirat Mantim; Korbua Chaisiwamongkhol; Kanchana Uraisin; Peter C Hauser; Prapin Wilairat; Duangjai Nacapricha
Journal:  Molecules       Date:  2020-05-13       Impact factor: 4.411

5.  [Multimaterial 3D-printed contactless conductivity/laser-induced fluorescence dual-detection cell for capillary electrophoresis].

Authors:  Piwang Zhang; Liye Yang; Qiang Liu; Shangui Lu; Ying Liang; Min Zhang
Journal:  Se Pu       Date:  2021-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.