Literature DB >> 19949117

Mid-term results of the modular ANCA-Fit femoral component in total hip replacement.

C M Blakey1, V K Eswaramoorthy, L C Hamilton, L C Biant, R E Field.   

Abstract

We report the minimum five-year follow-up of 352 primary total hip replacements using the uncemented hydroxyapatite-coated ANCA-Fit femoral component with a modular neck and head. The series comprised 319 patients (212 men, 107 women) with a mean age at operation of 64.4 years (28 to 97). The principal diagnosis was osteoarthritis. A total of 18 patients (21 hips) died before their follow-up at five years, nine patients (11 hips) were lost to follow-up, and four (four hips) declined further follow-up. Patient-reported outcomes have been recorded for 288 patients (316 hips). Their mean Oxford Hip Score improved significantly from 41 points (16 to 57) pre-operatively to 20 points (12 to 44) at five-year follow-up. Radiological assessment showed good bony stability in 98% of implants. There were two cases of aseptic loosening of the femoral component. There were no clinical or radiological complications related to modularity. In our series we did not see the high rate of intra-operative fracture previously reported for this implant. This medium-term follow-up study demonstrates that the clinical outcome of the ANCA-Fit femoral component is, to date, comparable with that of other metaphyseal loading femoral components.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19949117     DOI: 10.1302/0301-620X.91B12.22638

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  8 in total

1.  Long-term survivorship and complication rate comparison of a cementless modular stem and cementless fixed neck stems for primary total hip replacement.

Authors:  David A Fitch; Cristina Ancarani; Barbara Bordini
Journal:  Int Orthop       Date:  2015-07-09       Impact factor: 3.075

2.  Outcomes of neck modularity in total hip arthroplasty: an Italian perspective.

Authors:  R Papalia; A Di Martino; A Caldaria; B Zampogna; V Denaro
Journal:  Musculoskelet Surg       Date:  2019-01-23

3.  High Risk of Failure With Bimodular Femoral Components in THA.

Authors:  Aidin Eslam Pour; Robert Borden; Takayuki Murayama; Mary Groll-Brown; J David Blaha
Journal:  Clin Orthop Relat Res       Date:  2015-09-01       Impact factor: 4.176

Review 4.  How have alternative bearings and modularity affected revision rates in total hip arthroplasty?

Authors:  William M Mihalko; Markus A Wimmer; Carol A Pacione; Michel P Laurent; Robert F Murphy; Carson Rider
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

5.  Mid-term outcomes of titanium modular neck femoral stems in revision total hip arthroplasty.

Authors:  Hervé Ouanezar; Thomas Jalaguier; Florent Franck; Vincent Pibarot; Hugo Bothorel; Mo Saffarini; Jean-Pierre Piton
Journal:  Ann Transl Med       Date:  2019-03

6.  Bilateral neck fracture in bimodular femoral stem after primary total hip arthroplasty: a case report.

Authors:  Samo K Fokter; Nenad Gubeljak; Jožef Predan; Jure Sevšek; Jan Zajc; Zmago Krajnc
Journal:  BMC Musculoskelet Disord       Date:  2021-04-16       Impact factor: 2.362

Review 7.  Hip Arthroplasty Pseudotumors: Pathogenesis, Imaging, and Clinical Decision Making.

Authors:  Derik L Davis; James J Morrison
Journal:  J Clin Imaging Sci       Date:  2016-04-29

8.  Midterm outcomes of titanium modular femoral necks in total hip arthroplasty.

Authors:  Thurial Collet; Jean-Pierre Atanasiu; Jean-Baptiste de Cussac; Kamal Oufroukhi; Hugo Bothorel; Mo Saffarini; François Badatcheff
Journal:  Ann Transl Med       Date:  2017-10
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.