Reliability of an external loop recorder for automatic recognition and transtelephonic ECG transmission of atrial fibrillation.

Axel Müller1, Wilfried Scharner, Tilo Borchardt, Wolfgang Och, Harald Korb.   

Abstract

In order to test a newly developed algorithm for detecting atrial fibrillation in clinical practice, we carried out parallel recordings using a conventional 24-h electrocardiogram (ECG) monitor and telemonitoring with an external loop recorder. Recordings were made in 24 patients with persistent atrial fibrillation and in another 24 patients with sinus rhythm. Atrial fibrillation was detected immediately in 23 of 24 patients with persistent atrial fibrillation and 20 min after fitting the single-channel loop recorder in the 24th patient (sensitivity 100%). On average, 3.1 false positives (i.e. detection of an episode, including the end or beginning of atrial fibrillation) were transmitted per patient. The sensitivity of the algorithms for automatically detecting bradycardiac and tachycardiac atrial fibrillation was also high. In 12 of 24 patients with sinus rhythm, false-positive tele-ECGs were transmitted. These were caused by supraventricular or ventricular extrasystoles and by sinus arrhythmias or sinoatrial (SA) blocks. The external loop recorder was very effective at detecting paroxysmal atrial fibrillation. Possible indications for the clinical use of this recorder include, in addition to diagnosis, monitoring patients for atrial fibrillation recurrence after cardioversion or catheter ablation.

Entities:  

Mesh:

Year:  2009        PMID: 19948705     DOI: 10.1258/jtt.2009.090402

Source DB:  PubMed          Journal:  J Telemed Telecare        ISSN: 1357-633X            Impact factor:   6.184


  6 in total

1.  Continuation of vitamin K antagonists as acceptable anticoagulation regimen in patients undergoing pulmonary vein isolation.

Authors:  B Oude Velthuis; J Stevenhagen; J M van Opstal; M F Scholten
Journal:  Neth Heart J       Date:  2012-01       Impact factor: 2.380

Review 2.  Cryptogenic Stroke And Role Of Loop Recorder.

Authors:  Jordi PérezRodon; Jaume FranciscoPascual; Nuria RivasGándara; Ivo RocaLuque; Neus Bellera; Àngel MoyaMitjans
Journal:  J Atr Fibrillation       Date:  2014-12-31

3.  Performance of an external transtelephonic loop recorder for automated detection of paroxysmal atrial fibrillation.

Authors:  Bob Oude Velthuis; Jorieke Bos; Karin Kraaier; Jeroen Stevenhagen; Jurren M van Opstal; Job van der Palen; Marcoen F Scholten
Journal:  Ann Noninvasive Electrocardiol       Date:  2013-09-09       Impact factor: 1.468

4.  External prolonged electrocardiogram monitoring in unexplained syncope and palpitations: results of the SYNARR-Flash study.

Authors:  E T Locati; A Moya; M Oliveira; H Tanner; R Willems; M Lunati; M Brignole
Journal:  Europace       Date:  2015-10-29       Impact factor: 5.214

5.  Use of three-dimensional computed tomography overlay for real-time cryoballoon ablation in atrial fibrillation reduces radiation dose and contrast dye.

Authors:  B Oude Velthuis; M Molenaar; H G Reinhart Dorman; J Y Stevenhagen; M F Scholten; J van der Palen; J M van Opstal
Journal:  Neth Heart J       Date:  2017-06       Impact factor: 2.380

6.  Improved detection of paroxysmal atrial fibrillation utilizing a software-assisted electrocardiogram approach.

Authors:  Jürgen R Schaefer; Dieter Leussler; Ludger Rosin; David Pittrow; Thomas Hepp
Journal:  PLoS One       Date:  2014-02-28       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.