Literature DB >> 19945710

Capillary isoelectric focusing coupled offline to matrix assisted laser desorption/ionization mass spectrometry.

Noah G Weiss1, Nicole L Zwick, Mark A Hayes.   

Abstract

This work presents several critical details for making cIEF-MALDI-MS a robust technique which will allow for more routine application and aid in automation. This includes emphasis on the hardware necessary for syringe pump mobilization and proper protocol for preventing disruption from gas bubbles. Following these guidelines, excellent elution time reproducibility is demonstrated for six pI markers (RSD <5%). Additionally, the pI markers are used to calibrate the pH gradient and determine experimental pIs of proteins detected offline by mass spectrometry. This was demonstrated using a standard protein mixture of myoglobin and two forms of beta-lactoglobulin. Experimental determination of protein pIs and molecular weights were found to be in agreement with literature values. The technical details discussed provide a sound foundation for applying the offline coupling of MALDI-MS with cIEF. Copyright 2009 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19945710      PMCID: PMC3319405          DOI: 10.1016/j.chroma.2009.11.047

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  11 in total

1.  On-target fraction collection for the off-line coupling of capillary isoelectric focusing with matrix-assisted laser desorption/ionization mass spectrometry.

Authors:  Anne Chartogne; Marco Gaspari; Sonja Jespersen; Brigitte Buscher; Elwin Verheij; Robert van der Heijden Rv; Ubbo Tjaden; Jan van der Greef
Journal:  Rapid Commun Mass Spectrom       Date:  2002       Impact factor: 2.419

Review 2.  Determination of the isoelectric point of proteins by capillary isoelectric focusing.

Authors:  Pier Giorgio Righetti
Journal:  J Chromatogr A       Date:  2004-05-28       Impact factor: 4.759

3.  Comprehensive two-dimensional separation in coupling of reversed-phase chromatography with capillary isoelectric focusing followed by MALDI-MS identification using on-target digestion for intact protein analysis.

Authors:  Wenjia Yu; Yan Li; Chunhui Deng; Xiangmin Zhang
Journal:  Electrophoresis       Date:  2006-06       Impact factor: 3.535

4.  Improved repeatability and matrix-assisted desorption/ionization - time of flight mass spectrometry compatibility in capillary isoelectric focusing.

Authors:  Linda H H Silvertand; Javier Sastre Toraño; Gerhardus J de Jong; Wouter P van Bennekom
Journal:  Electrophoresis       Date:  2008-05       Impact factor: 3.535

5.  Long-term precision in capillary isoelectric focusing for protein analysis.

Authors:  Adhitasari Suratman; Hermann Wätzig
Journal:  J Sep Sci       Date:  2008-06       Impact factor: 3.645

6.  Capillary isoelectric focusing hyphenated to single- and multistage matrix-assisted laser desorption/ionization-mass spectrometry using automated sheath-flow-assisted sample deposition.

Authors:  Michael Lechner; Alexandra Seifner; Andreas M Rizzi
Journal:  Electrophoresis       Date:  2008-05       Impact factor: 3.535

Review 7.  Capillary isoelectric focusing.

Authors:  R Rodriguez-Diaz; T Wehr; M Zhu
Journal:  Electrophoresis       Date:  1997-11       Impact factor: 3.535

8.  Analysis of protein fractions by micropreparative capillary isoelectric focusing and matrix-assisted laser desorption time-of-flight mass spectrometry.

Authors:  F Foret; O Müller; J Thorne; W Götzinger; B L Karger
Journal:  J Chromatogr A       Date:  1995-11-17       Impact factor: 4.759

9.  Development of a high-performance capillary isoelectric focusing technique with application to studies of microheterogeneity in chicken conalbumin.

Authors:  T L Huang; M Richards
Journal:  J Chromatogr A       Date:  1997-01-03       Impact factor: 4.759

10.  Development and characterization of cIEF-MALDI-TOF MS for protein analysis.

Authors:  Linda H H Silvertand; Javier Sastre Toraño; Gerhardus J de Jong; Wouter P van Bennekom
Journal:  Electrophoresis       Date:  2009-05       Impact factor: 3.535

View more
  4 in total

1.  Examining serum amyloid P component microheterogeneity using capillary isoelectric focusing and MALDI-MS.

Authors:  Noah G Weiss; Jason W Jarvis; Randall W Nelson; Mark A Hayes
Journal:  Proteomics       Date:  2010-12-01       Impact factor: 3.984

Review 2.  Recent advances in coupling capillary electrophoresis-based separation techniques to ESI and MALDI-MS.

Authors:  Xuefei Zhong; Zichuan Zhang; Shan Jiang; Lingjun Li
Journal:  Electrophoresis       Date:  2013-12-05       Impact factor: 3.535

3.  Isoelectric focusing in a drop.

Authors:  Noah G Weiss; Mark A Hayes; Antonio A Garcia; Rafat R Ansari
Journal:  Langmuir       Date:  2010-11-30       Impact factor: 3.882

4.  Field-free remobilization of proteins after isoelectric focusing in packed capillaries.

Authors:  Yimin Hua; Brooke M Koshel; Mary J Wirth
Journal:  Anal Chem       Date:  2010-10-08       Impact factor: 6.986

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.