Literature DB >> 19945499

Effect of a new liner/base on human dentin permeability.

Richard P Rusin1, Kelli Agee, Michael Suchko, David H Pashley.   

Abstract

OBJECTIVES: Resin-modified glass ionomers (RMGI) have demonstrated clinical success in their ability to minimize post-operative sensitivity of restorations. RMGIs have been recently introduced as paste-liquid systems for convenience of clinical usage. The objective of this study was to measure the ability of a new paste-liquid RMGI liner/base to reduce fluid flow through human dentin.
METHODS: Dentin permeability was measured on human crown sections on etched dentin, using etched dentin as a model for the exposed tubules typical of root sensitivity, and permitting measurement of the maximum permeability. In the one group, the etched dentin was coated with the RMGI, and pre- and post-treatment permeability was measured on the coated dentin. In the second group, a smear layer was created on the dentin with sandpaper, then the samples were coated with the RMGI; permeability was measured on the smeared and coated dentin. Samples from each group were sectioned and examined via scanning electron microscopy (SEM).
RESULTS: The new paste-liquid RMGI liner/base significantly reduced fluid flow through dentin, and exhibited excellent seal on dentin with either a smear layer or open tubules. SEM images show evidence that the RMGI infiltrated the smear layer with resin during placement, penetrated dentin tubules, and formed resin tags in acid-etched dentin.
CONCLUSIONS: Based on these results, combined with previous research on adhesion and microleakage, it is concluded that the new RMGI liner/base should minimize post-operative sensitivity in restorations. Copyright 2009 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19945499     DOI: 10.1016/j.jdent.2009.11.004

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  5 in total

1.  Effects of two disinfection/sterilization methods for dentin specimens on dentin permeability.

Authors:  Ruodan Jiang; Yongxiang Xu; Hong Lin
Journal:  Clin Oral Investig       Date:  2018-06-14       Impact factor: 3.573

2.  Clinical evaluation of the efficacy of one self-adhesive composite in dental hypersensitivity.

Authors:  R Pinna; A Bortone; G Sotgiu; S Dore; P Usai; E Milia
Journal:  Clin Oral Investig       Date:  2015-01-23       Impact factor: 3.573

3.  The effect of different pulp capping methods on the intrapulpal temperature when using light-cured procedures.

Authors:  Dayane Oliveira; Mateus-Garcia Rocha; Panagiotis Zoidis; Patricia Pereira; Ana-Paula Ribeiro
Journal:  J Clin Exp Dent       Date:  2022-08-01

Review 4.  Adhesive sealing of dentin surfaces in vitro: A review.

Authors:  Manar M Abu Nawareg; Ahmed Z Zidan; Jianfeng Zhou; Ayaka Chiba; Jungi Tagami; David H Pashley
Journal:  Am J Dent       Date:  2015-12       Impact factor: 1.522

5.  Comparison of indirect pulp treatment and iRoot BP Plus pulpotomy in primary teeth with extremely deep caries: a prospective randomized trial.

Authors:  Xiaoxian Chen; Hongmei Zhang; Jie Zhong; Wenjuan Yan; Bichen Lin; Meili Ding; Shihua Xue; Bin Xia
Journal:  Clin Oral Investig       Date:  2020-10-15       Impact factor: 3.573

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.